High-precision measurements of δ2H, δ18O and δ17O in water with the aid of cavity ring-down laser spectroscopy

被引:27
|
作者
Pierchala, Anna [1 ]
Rozanski, Kazimierz [1 ]
Dulinski, Marek [1 ]
Gorczyca, Zbigniew [1 ]
Marzec, Michal [1 ]
Czub, Robert [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, Krakow, Poland
关键词
Cavity ring-down spectroscopy; hydrogen-2; isotope measurements; methods and equipment; oxygen-17; excess; oxygen-18; QA; QC; uncertainty; ISOTOPE-RATIO; SPECTROMETER; CALIBRATION; O-17-EXCESS; SURFACES; OXYGEN;
D O I
10.1080/10256016.2019.1609959
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A thorough evaluation of measurement uncertainty together with control of short-term and long-term precision of measurements should be a basis of any successful quality assurance/quality control (QA/QC) strategy aimed at maintaining a high quality of the analytical process. Here we present the results of a comprehensive assessment of the analytical performance of a Picarro L2140-i CRDS laser spectrometer analysing delta H-2, delta O-18 and delta O-17 in water. The assessment is based on results obtained during 15 months of continuous operation of this instrument (February 2017 to May 2018). The short-term precision of measured and derived quantities was 0.11, 0.036, 0.028, 0.23 parts per thousand and 11 per meg, for delta H-2, delta O-18, delta O-17, d-excess and Delta O-17, respectively, and is comparable to the precision reported by the manufacturer. The long-term precision of the L2140-i, defined as standard uncertainty of the time series of 153 analyses of a laboratory standard conducted throughout 15 months, was roughly two times lower (0.24, 0.053, 0.038, 0.37 parts per thousand and 21 per meg, for delta H-2, delta O-18, delta O-17, d-excess and Delta O-17). In-depth assessment of the measurement uncertainty of a single analysis revealed that assigned uncertainty of the calibration standards is an important component of the uncertainty budget, especially in case of delta H-2 analysis.
引用
收藏
页码:290 / 307
页数:18
相关论文
共 50 条
  • [1] Improving memory effect correction to achieve high-precision analysis of δ17O, δ18O, δ2H, 17O-excess and d-excess in water using cavity ring-down laser spectroscopy
    Vallet-Coulomb, Christine
    Couapel, Martine
    Sonzogni, Corinne
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (14)
  • [2] Isotope effects accompanying δ2H, δ18O and δ17O analyses of aqueous saline solutions using cavity ring-down laser spectroscopy
    Dulinski, Marek
    Rozanski, Kazimierz
    Pierchala, Anna
    Gorczyca, Zbigniew
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (04)
  • [3] Simultaneous analysis of 17O/16O, 18O/16O and 2H/1H of gypsum hydration water by cavity ring-down laser spectroscopy
    Gazquez, Fernando
    Mather, Ian
    Rolfe, James
    Evans, Nicholas P.
    Herwartz, Daniel
    Staubwasser, Michael
    Hodell, David A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (21) : 1997 - 2006
  • [4] Cavity Ring-Down Spectroscopy Performance and Procedures for High-Throughput δ18O and δ2H Measurement in Water Using "Express" Mode
    Galili, Nir
    Blattmann, Thomas M.
    Somlyay, Anna
    Gallarotti, Nora
    Eglinton, Timothy I.
    Hemingway, Jordon D.
    APPLIED SPECTROSCOPY, 2025,
  • [5] Performance assessment of a cavity ring-down laser spectrometer: achieving better precision and accuracy in the measurement of δ18O and δ2H in liquid water samples
    Prado-Perez, A. J.
    Rodriguez-Arevalo, J.
    Diaz-Teijeiro, M. F.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (01)
  • [6] Calibrated high-precision 17O-excess measurements using cavity ring-down spectroscopy with laser-current-tuned cavity resonance
    Steig, E. J.
    Gkinis, V.
    Schauer, A. J.
    Schoenemann, S. W.
    Samek, K.
    Hoffnagle, J.
    Dennis, K. J.
    Tan, S. M.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2014, 7 (08) : 2421 - 2435
  • [7] Evaluation of carrier gases for high-precision water isotopic measurements by cavity ring-down laser spectroscopy
    Xing, Meng
    Liu, Weiguo
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2016, 44 (04) : 410 - 424
  • [8] Online high-precision δ2H and δ18O analysis in water by pyrolysis
    Lu, Feng H.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (19) : 3144 - 3150
  • [9] Cavity ring down spectroscopy of 18O and 17O enriched carbon dioxide near 795 nm
    Pan, H.
    Li, X. -F.
    Lu, Y.
    Liu, A. -W.
    Perevalov, V. I.
    Tashkun, S. A.
    Hu, S. -M.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2013, 114 : 42 - 44
  • [10] High-precision measurements of 17O/16O and 18O/16O ratios in CO2
    Barkan, Eugeni
    Luz, Boaz
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (23) : 2733 - 2738