QUANTITATIVE EVALUATION OF HEPATIC MICROVASCULAR PERFUSION AFTER ISCHEMIA-REPERFUSION INJURY IN RABBITS BY CONTRAST-ENHANCED ULTRASOUND PERFUSION IMAGING

被引:3
|
作者
Xie, Fang [1 ]
Fei, Xiang [1 ]
Zhang, Ming-Bo [1 ]
Zhang, Yan [1 ]
Wang, Hong-Wei [1 ]
Tang, Jie [1 ]
Tang, Wen-Bo [1 ]
Luo, Yu-Kun [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Ultrasound, 28 Fuxing Rd, Beijing 100853, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2018年 / 44卷 / 05期
基金
中国国家自然科学基金;
关键词
Hepatic microvascular perfusion; Ischemia-reperfusion injury; Contrast-enhanced ultrasound; LIVER-TRANSPLANTATION; MYOCARDIAL-PERFUSION; ADHESION MOLECULES; ENDOTHELIAL-CELLS; TUMOR PERFUSION; QUANTIFICATION; MICROCIRCULATION; ULTRASONOGRAPHY; PARAMETERS; ROLES;
D O I
10.1016/j.ultrasmedbio.2018.01.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this study was to evaluate microvascular perfusion after liver ischemia-reperfusion injury (IRI) in rabbits using the "flash-replenishment" method of contrast-enhanced ultrasound (CEUS) perfusion imaging. Twenty-eight rabbits underwent either 30, 60 or 90 min of ischemia and 120 min of reperfusion. CEUS perfusion imaging was performed using the "flash-replenishment" model, and hepatic microvascular perfusion parameters, including peak intensity (PI), area under the curve (AUC), and hepatic artery-to-vein transit time (HA-HVTT), were calculated. Prolonged ischemia upregulated intracellular adhesion molecule-1 (ICAM-1), alanine transaminase (ALT) and aspartate transaminase (AST) levels. Longer ischemia decreased PI and AUC, but increased HA-HVTT. The perfusion parameters were significantly correlated with Suzuki's pathology scores and ALT and AST levels. The "flash-replenishment" method of CEUS perfusion imaging is an accurate and non-invasive method for evaluating hepatic microvascular perfusion and provides a valuable experimental basis for early prediction of liver IRI damage after liver transplantation or liver resection. (E-mail: lyk301@163.com) (c) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1053 / 1062
页数:10
相关论文
共 50 条
  • [1] QUANTITATIVE EVALUATION OF RENAL CORTEX PERFUSION USING CONTRAST-ENHANCED ULTRASOUND IMAGING PARAMETERS IN ISCHEMIA-REPERFUSION INJURY IN RABBITS
    Luo, Zhijian
    Liu, Yulu
    Tang, Ziyi
    Liu, Jialing
    Xu, Xuemei
    Li, Mingxing
    Dai, Yan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (11): : 3253 - 3262
  • [2] QUANTITATIVE ANALYSIS OF HEPATIC MICROCIRCULATION IN RABBITS AFTER LIVER ISCHEMIA-REPERFUSION INJURY USING CONTRAST-ENHANCED ULTRASOUND
    Li, Haiyuan
    Lu, Jingning
    Zhou, Xiaofeng
    Pan, Denghua
    Guo, Dequan
    Ling, Haiying
    Yang, Hong
    He, Yun
    Chen, Gang
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10): : 2469 - 2476
  • [3] Quantitative evaluation of renal parenchymal perfusion using contrast-enhanced ultrasonography in renal ischemia-reperfusion injury in dogs
    Lee, Gahyun
    Jeon, Sunghoon
    Lee, Sang-kwon
    Cheon, Byunggyu
    Moon, Sohyeon
    Park, Jun-Gyu
    Cho, Kyoung-Oh
    Choi, Jihye
    JOURNAL OF VETERINARY SCIENCE, 2017, 18 (04) : 507 - 514
  • [4] Acute Outflow Obstruction of Hepatic Veins in Rabbits: Quantitative Analysis of Hepatic Perfusion on Contrast-Enhanced Ultrasound
    Kim, Kyoung Won
    Kim, Pyo Nyun
    Shin, Ji Hoon
    Shin, Dong Ho
    Jeong, Woo Kyoung
    Won, Hyung Jin
    Shin, Yong Moon
    Lee, Won Jae
    Lee, Moon Gyu
    Song, Gi-Won
    Hwang, Shin
    Lee, Sung-Gyu
    LIVER TRANSPLANTATION, 2010, 16 (06) : S157 - S157
  • [5] Renal 3D photoacoustic imaging and contrast-enhanced ultrasound to assess oxygenation and perfusion and to predict fibrosis after ischemia-reperfusion
    Schleef, Maxime
    Leon, Christelle
    Pillot, Bruno
    Chanon, Stephanie
    Bidaux, Gabriel
    Juillard, Laurent
    Guebre-Egziabher, Fitsum
    Baetz, Delphine
    Lemoine, Sandrine
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39 : I2773 - I2774
  • [6] Renal 3D photoacoustic imaging and contrast-enhanced ultrasound to assess oxygenation and perfusion and to predict fibrosis after ischemia-reperfusion
    Schleef, Maxime
    Leon, Christelle
    Pillot, Bruno
    Chanon, Stephanie
    Bidaux, Gabriel
    Juillard, Laurent
    Guebre-Egziabher, Fitsum
    Baetz, Delphine
    Lemoine, Sandrine
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39
  • [7] Contrast-enhanced ultrasound: A promising method for renal microvascular perfusion evaluation
    Wang, Ling
    Mohan, Chandra
    JOURNAL OF TRANSLATIONAL INTERNAL MEDICINE, 2016, 4 (03) : 104 - 108
  • [8] Repeatability of the "flash-replenishment" method in contrast-enhanced ultrasound for the quantitative assessment of hepatic microvascular perfusion
    Xie, Fang
    Wan, Wen-Bo
    Fei, Xiang
    Zhang, Ming-Bo
    Zhang, Yan
    Wang, Hong-Wei
    Tang, Jie
    Tang, Wen-Bo
    Luo, Yu-Kun
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2018, 51 (04)
  • [9] Contrast-enhanced ultrasound perfusion imaging of organs
    Jung, Ernst-Michael
    Weber, Marc-Andre
    Wiesinger, Isabel
    RADIOLOGE, 2021,
  • [10] Contrast-Enhanced Ultrasound for Myocardial Perfusion Imaging
    Bulte, Carolien S. E.
    Slikkerveer, Jeroen
    Meijer, Rick I.
    Gort, Dennis
    Kamp, Otto
    Loer, Stephan A.
    de Marchi, Stefano F.
    Vogel, Rolf
    Boer, Christa
    Bouwman, R. Arthur
    ANESTHESIA AND ANALGESIA, 2012, 114 (05): : 938 - 945