Biostability of an implantable glucose sensor chip

被引:6
|
作者
Froehlich, M. [1 ]
Birkholz, M. [1 ]
Ehwald, K. E. [1 ]
Kulse, P. [1 ]
Fursenko, O. [1 ]
Katzer, J. [1 ]
机构
[1] IHP, D-15236 Frankfurt, Oder, Germany
关键词
AFFINITY SENSOR; TECHNOLOGY; ARRAYS;
D O I
10.1088/1757-899X/41/1/012022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Surface materials of an implantable microelectronic chip intended for medical applications were evaluated with respect to their long-term stability in bio-environments. The sensor chip shall apply in a glucose monitor by operating as a microviscosimeter according to the principle of affinity viscosimetry. A monolithic integration of a microelectromechanical system (MEMS) into the sensor chip was successfully performed in a combined 0.25 mu m CMOS/BiCMOS technology. In order to study material durability and biostability of the surfaces, sensor chips were exposed to various in vitro and in vivo tests. Corrosional damage of SiON, SiO2 and TiN surfaces was investigated by optical microscopy, ellipsometry and AFM. The results served for optimizing the Back-end-of-Line (BEoL) stack, from which the MEMS was prepared. Corrosion of metal lines could significantly be reduced by improving the topmost passivation layer. The experiments revealed no visible damage of the actuator or other functionally important MEMS elements. Sensor chips were also exposed to human body fluid for three month by implantation into the abdomen of a volunteer. Only small effects were observed for layer thickness and R-a roughness after explantation. In particular, TiN as used for the actuator beam showed no degradation by biocorrosion. The highest degradation rate of about 50 nm per month was revealed for the SiON passivation layer. These results suggest that the sensor chip may safely operate in subcutaneous tissue for a period of several months.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] IMPLANTABLE GLUCOSE SENSOR
    WILKINS, E
    WILKINS, MG
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1983, 5 (04): : 309 - 315
  • [2] BIOSTABILITY CONSIDERATIONS FOR IMPLANTABLE POLYURETHANES
    COURY, AJ
    STOKES, KB
    CAHALAN, PT
    SLAIKEU, PC
    [J]. LIFE SUPPORT SYSTEMS, 1987, 5 (01): : 25 - 39
  • [3] Implantable glucose sensor.
    Yu, YZ
    Jahn, L
    Crothall, KD
    DeStefano, M
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U115 - U115
  • [4] AN IMPLANTABLE ELECTROCHEMICAL GLUCOSE SENSOR
    LERNER, H
    GINER, J
    SOELDNER, JS
    COLTON, CK
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1984, 428 (JUN) : 263 - 278
  • [5] IMPLANTABLE ELECTROCATALYTIC GLUCOSE SENSOR
    LAGER, W
    VONLUCADOU, I
    NISCHIK, H
    NOWAK, T
    PREIDEL, W
    RUPRECHT, L
    STANZEL, MJ
    TEGEDER, V
    [J]. HORMONE AND METABOLIC RESEARCH, 1994, 26 (11) : 526 - 530
  • [6] DEVELOPMENT OF AN IMPLANTABLE ELECTROCATALYTIC GLUCOSE SENSOR
    GEBHARDT, U
    LUFT, G
    RICHTER, GJ
    STURM, FV
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1978, 5 (04): : 607 - 624
  • [7] IMPLANTABLE GLUCOSE SENSOR EXPECTED SOON
    WINGARD, LB
    SPAETH, EE
    [J]. BIO-TECHNOLOGY, 1989, 7 (02): : 116 - 116
  • [8] A Wireless Powered Implantable Bio-Sensor Tag System-on-Chip for Continuous Glucose Monitoring
    Guan, Shuo
    Gu, Jingren
    Shen, Zhonghan
    Wang, Junyu
    Huang, Yue
    Mason, Andrew
    [J]. 2011 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2011, : 193 - 196
  • [9] A MINIATURE GLUCOSE SENSOR, IMPLANTABLE IN THE BLOOD STREAM
    KONDO, T
    ITO, K
    OHKURA, K
    ITO, K
    IKEDA, S
    [J]. DIABETES CARE, 1982, 5 (03) : 218 - 221
  • [10] A NEW GLUCOSE SENSOR FOR IMPLANTABLE ARTIFICIAL PANCREAS
    IKEDA, S
    AOYAMA, N
    ITO, K
    OOKURA, K
    ICHIHASHI, H
    KONDO, T
    [J]. NIPPON KAGAKU KAISHI, 1980, (10) : 1554 - 1561