Experimental investigation on flexural behaviour of HSS stud connected steel-concrete composite girders

被引:0
|
作者
Prakash, Amar [1 ]
Anandavalli, N. [1 ]
Madheswaran, C. K. [1 ]
Lakshmanan, N. [1 ]
机构
[1] CSIR, Struct Engn Res Ctr, Madras 600113, Tamil Nadu, India
来源
STEEL AND COMPOSITE STRUCTURES | 2012年 / 13卷 / 03期
关键词
steel-concrete composite girder; HSS stud connector; ductility; efficiency factor; interface slip; local buckling; SHEAR CONNECTORS; STATIC BEHAVIOR; BONDED STEEL; BEAMS; STRENGTH;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, experimental investigations on high strength steel (HSS) stud connected steel-concrete composite (SCC) girders to understand the effect of shear connector density on their flexural behaviour is presented. SCC girder specimens were designed for three different shear capacities (100%, 85%, and 70%), by varying the number of stud connectors in the shear span. Three SCC girder specimens were tested under monotonic/quasi-static loading, while three similar girder specimens were subjected to non-reversal cyclic loading under simply supported end conditions. Details of casting the specimens, experimental set-up, and method of testing, instrumentation for the measurement of deflection, interface-slip and strain are discussed. It is found that SCC girder specimen designed for full shear capacity exhibits interface slip for loads beyond 25% of the ultimate load capacity. Specimens with lesser degree of shear connection show lower values of load at initiation of slip. Very good ductility is exhibited by all the HSS stud connected SCC girder specimens. It is observed that the ultimate moment of resistance as well as ductility gets reduced for HSS stud connected SCC girder with reduction in stud shear connector density. Efficiency factor indicating the effectiveness of high strength stud connectors in resisting interface forces is estimated to be 0.8 from the analysis. Failure mode is primarily flexure with fracturing of stud connectors and characterised by flexural cracking and crushing of concrete at top in the pure bending region. Local buckling in the top flange of steel beam was also observed at the loads near to failure, which is influenced by spacing of studs and top flange thickness of rolled steel section. One of the recommendations is that the ultimate load capacity can be limited to 1.5 times the plastic moment capacity of the section such that the post peak load reduction is kept within limits. Load-deflection behaviour for monotonic tests compared well with the envelope of load-deflection curves for cyclic tests. It is concluded from the experimental investigations that use of HSS studs will reduce their numbers for given loading, which is advantageous in case of long spans. Buckling of top flange of rolled section is observed at failure stage. Provision of lips in the top flange is suggested to avoid this buckling. This is possible in case of longer spans, where normally built-up sections are used.
引用
收藏
页码:239 / 258
页数:20
相关论文
共 50 条
  • [1] Experimental studies on the flexural behaviour of steel-concrete composite beams with transverse and longitudinal hidden girders
    Yang, Jianjun
    Chen, Huaguo
    Hu, Shengliang
    Gan, Vincent J. L.
    ENGINEERING STRUCTURES, 2019, 179 : 583 - 594
  • [2] Partially Connected Steel-Concrete Composite Plate Girders
    Yatim, Mohd Yazmil Md
    Shanmugam, Nandivaram E.
    Badaruzzaman, Wan Hamidon Wan
    JURNAL KEJURUTERAAN, 2011, 23 : 1 - 10
  • [3] Effect of concrete crushing on flexural strength of steel-concrete composite girders
    Gupta, Vivek Kumar
    Okui, Yoshiaki
    Inaba, Naofumi
    Nagai, Masatsugu
    Structural Engineering/Earthquake Engineering, 2007, 24 (02)
  • [4] Experimental investigation on the flexural behavior of steel-concrete composite beams with U-shaped steel girders and angle connectors
    Liu, Yong
    Guo, Lanhui
    Qu, Bing
    Zhang, Sumei
    ENGINEERING STRUCTURES, 2017, 131 : 492 - 502
  • [5] Experimental study on steel-concrete composite plate girders
    Shanmugam, NE
    Baskar, K
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 793 - 799
  • [6] Experimental behaviour of steel-concrete composite box girders subject bending, shear and torsion
    Soto, Alejandro Giraldo
    Perez Caldentey, Alejandro
    Corres Peiretti, Hugo
    Calvo Benitez, Jorge
    ENGINEERING STRUCTURES, 2020, 206
  • [7] Flexural behavior of steel-concrete composite beams with U-shaped steel girders
    Liu, Y.
    Guo, L. H.
    Li, Z. G.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 161 - 167
  • [8] Flexural property of damaged steel-concrete composite girders strengthened with CFRP sheet
    Hou, Wenyu
    Gong, Xiaolong
    Li, Yanfeng
    Huang, Fulong
    Wang, Jiaqi
    ADVANCES IN MECHANICAL ENGINEERING, 2024, 16 (10)
  • [9] Experimental Study on Fatigue Performance of Steel-Concrete Composite Girders
    El-Zohairy, Ayman
    Salim, Hani
    Saucier, Aaron
    FRACTURE, FATIGUE, FAILURE AND DAMAGE EVOLUTION, VOL 6, 2019, : 77 - 83
  • [10] Experimental Investigation of the Shear Behavior of Slender Continuous Steel-Concrete Composite Girders in Hogging Moment
    Men, Pengfei
    Di, Jin
    Qin, Fengjiang
    Su, Yi
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (01)