Lateral Flow Immunoassay Using Europium Chelate-Loaded Silica Nanoparticles as Labels

被引:104
|
作者
Xia, Xiaohu [2 ]
Xu, Ye [2 ]
Zhao, Xilin [2 ,3 ]
Li, Qingge [1 ,2 ,4 ]
机构
[1] Xiamen Univ, Sch Life Sci, Dept Biomed Sci, Mol Diagnost Lab, Xiamen 361005, Fujian, Peoples R China
[2] Xiamen Univ, Sch Life Sci, Key Lab Minist Educ Cell Biol & Tumor Cell Engn, Xiamen 361005, Fujian, Peoples R China
[3] Univ Med & Dent New Jersey, Publ Hlth Res Inst, Newark, NJ USA
[4] Xiamen Univ, Key Lab Chem Biol Fujian, Xiamen 361005, Fujian, Peoples R China
关键词
RESOLVED IMMUNOFLUOROMETRIC ASSAYS; PROSTATE-SPECIFIC ANTIGEN; ULTRASENSITIVE DETECTION; LIPOSOME IMMUNOASSAY; AFLATOXIN B-1; CHROMATOGRAPHY; FLUORESCENCE; SYSTEM;
D O I
10.1373/clinchem.2008.114561
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Despite their ease of use, lateral flow immunoassays (LFIAs) often suffer from poor quantitative discrimination and low analytical sensitivity. We explored the use of a novel class of europium chelate-loaded silica nanoparticles as labels to overcome these limitations. METHODS: Antibodies were covalently conjugated onto europium chelate-loaded silica nanoparticles with dextran as a linker. The resulting conjugates were used as labels in LFIA for detection of hepatitis B surface antigen (HBsAg). We performed quantification with a digital camera and Adobe Photoshop software. We also used 286 clinical samples to compare the proposed method with a quantitative ELISA. RESULTS: A detection limit of 0.03 mu g/L was achieved, which was 100 times lower than the colloidal gold-based LFIAs and lower than ELISA. A precise quantitative dose-response curve was obtained, and the linear measurement range was 0.05-3.13 mu g/L, within which the CVs were 2.3%-10.4%. Regression analysis of LFIA on ELISA results gave: log (LFIA) = -0.14 log (ELISA) + 1.03 mu g/L with r = 0.99 for the quantification of HBsAg in 35 positive serum samples. Complete agreement was observed for the qualitative comparison of 286 clinical samples assayed with LFIA and ELISA. CONCLUSIONS: Europium chelate-loaded silica nano-particle labels have great potential to improve LFIAs, making them useful not only for simple screening applications but also for more sensitive and quantitative immunoassays.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 50 条
  • [1] Europium chelate-loaded liposomes: A tool for the study of binding and integrity of liposomes
    Orellana, A
    Laukkanen, ML
    Keinanen, K
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 1996, 1284 (01): : 29 - 34
  • [2] Enhanced lateral flow immunoassay using gold nanoparticles loaded with enzymes
    Parolo, Claudio
    de la Escosura-Muniz, Alfredo
    Merkoci, Arben
    BIOSENSORS & BIOELECTRONICS, 2013, 40 (01): : 412 - 416
  • [3] Study of superparamagnetic nanoparticles as labels in the quantitative lateral flow immunoassay
    Wang, Yanyan
    Xu, Hong
    Wei, Meng
    Gu, Hongchen
    Xu, Quanfu
    Zhu, Wei
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (03): : 714 - 718
  • [4] Advantages of Highly Spherical Gold Nanoparticles as Labels for Lateral Flow Immunoassay
    Byzova, Nadezhda A.
    Zherdev, Anatoly, V
    Khlebtsov, Boris N.
    Burov, Andrey M.
    Khlebtsov, Nikolai G.
    Dzantiev, Boris B.
    SENSORS, 2020, 20 (12) : 1 - 15
  • [5] Rapid Monitoring of Vancomycin Concentration in Serum Using Europium (III) Chelate Nanoparticle-Based Lateral Flow Immunoassay
    Bian, Lun
    Liang, Junyu
    Zhao, Hui
    Ye, Ke
    Li, Zhaoyue
    Liu, Tiancai
    Peng, Jie
    Wu, Yingsong
    Lin, Guanfeng
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [6] Performance enhancement of the lateral flow immunoassay by use of composite nanoparticles as signal labels
    Yin, Xuechi
    Liu, Sijie
    Kukkar, Deepak
    Wang, Jianlong
    Zhang, Daohong
    Kim, Ki-Hyun
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2024, 170
  • [7] Lateral flow immunoassay using europium (III) chelate microparticles and time-resolved fluorescence for eosinophils and neutrophils in whole blood
    Rundstrom, Gerd
    Jonsson, Ann
    Martensson, Ola
    Mendel-Hartvig, Ib
    Venge, Pet
    CLINICAL CHEMISTRY, 2007, 53 (02) : 342 - 348
  • [8] Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips
    Liang, Rong-Liang
    Xu, Xu-Ping
    Liu, Tian-Cai
    Zhou, Jian-Wei
    Wang, Xian-Guo
    Ren, Zhi-Qi
    Hao, Fen
    Wu, Ying-Song
    ANALYTICA CHIMICA ACTA, 2015, 891 : 277 - 283
  • [9] COMPARISON OF EUROPIUM-DOPED NANOPARTICLES AND COLLOIDAL GOLD AS LABELS IN LATERAL FLOW BIOAFFINITY ASSAY
    Juntunen, E.
    Salminen, T.
    Myyrylainen, T.
    Pettersson, K.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S681 - S681
  • [10] Rapid and sensitive lateral flow immunoassay for influenza antigen using fluorescently-doped silica nanoparticles
    Suwussa Bamrungsap
    Chayachon Apiwat
    Warangkana Chantima
    Tararaj Dharakul
    Natpapas Wiriyachaiporn
    Microchimica Acta, 2014, 181 : 223 - 230