Calculating particle log reduction values based on pressure decay tests on Multibore® hollow fibre membranes

被引:4
|
作者
Heijnen, Martin [1 ]
Buchta, Patrick [1 ]
Winkler, Roland [1 ]
Berg, Peter [1 ]
机构
[1] Inge GmbH, D-86926 Greifenberg, Germany
关键词
Membrane; Integrity test; Pressure decay; Multibore (R); Log reduction value; INTEGRITY;
D O I
10.1080/19443994.2013.769483
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The Multibore (R) hollow fibre membrane has a distinct advantage in comparison to other hollow fibre membranes due to its extreme durability, which prevents fibre breaks to a very high degree. The integrity of a system nevertheless will need to be checked in order to make sure no membrane damage has occurred. The integrity of the membrane system is normally tested by means of a pressure decay test (PDT). The results of this test have to be interpreted so that a plant operator knows the actual log reduction value (LRV) of the plant. This paper deals with this interpretation and a formula is derived from which the LRV can be calculated. The method is partially based on the ASTM D6908-6906 method in which case, the air flow in an integrity test is compared to the air flow through a complete membrane breakage. It is shown that the PDT is sensitive enough to be able to detect a single broken membrane in even the largest membrane racks and that a 4-LRV can be guaranteed as long as the pressure decay rate is within the specified range.
引用
收藏
页码:4245 / 4252
页数:8
相关论文
共 1 条
  • [1] Tailoring the molecular weight cut off values of polyacrylonitrile based hollow fibre ultrafiltration membranes with improved fouling resistance by chemical modification
    Parashuram, K.
    Maurya, S. K.
    Rana, H. H.
    Singh, P. S.
    Ray, P.
    Reddy, A. V. R.
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2013, 425 : 251 - 261