Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance

被引:80
|
作者
Maleckis, Kaspars [1 ]
Anttila, Eric [1 ]
Aylward, Paul [1 ]
Poulson, William [1 ]
Desyatova, Anastasia [1 ]
MacTaggart, Jason [1 ]
Kamenskiy, Alexey [1 ]
机构
[1] Univ Nebraska Med Ctr, Dept Surg, 987690 Nebraska Med Ctr, Omaha, NE 68198 USA
基金
美国国家卫生研究院;
关键词
Femoropopliteal artery; Nitinol; Stent; Design; Peripheral arterial disease; SUPERFICIAL FEMORAL-ARTERY; SHAPE-MEMORY ALLOYS; PROXIMAL POPLITEAL ARTERIES; BARE-METAL STENTS; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; EXTREMITY BYPASS-SURGERY; FINITE-ELEMENT-ANALYSIS; ONE-YEAR OUTCOMES; BALLOON ANGIOPLASTY; RANDOMIZED-TRIAL;
D O I
10.1007/s10439-018-1990-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-term morbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD.
引用
收藏
页码:684 / 704
页数:21
相关论文
共 50 条
  • [1] Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance
    Kaspars Maleckis
    Eric Anttila
    Paul Aylward
    William Poulson
    Anastasia Desyatova
    Jason MacTaggart
    Alexey Kamenskiy
    Annals of Biomedical Engineering, 2018, 46 : 684 - 704
  • [2] Pioneering personalised design of femoropopliteal nitinol stents
    He, Ran
    Zhao, Liguo
    Silberschmidt, Vadim V.
    Willcock, Helen
    Vogt, Felix
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2021, 130
  • [3] Stenting of femoropopliteal lesions using interwoven nitinol stents
    Brescia, Alexander A.
    Wickers, Brian M.
    Correa, Juan Carlos
    Smeds, Mathew R.
    Jacobs, Donald L.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (06) : 1472 - 1478
  • [4] Comparison of Interwoven Nitinol and Drug-Eluting Stents for Endovascular Treatment of Femoropopliteal Artery Disease
    Abi-Khalil, Jad
    Astarci, Parla
    Elens, Maxime
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2022, 40
  • [5] Comparison Between Interwoven Nitinol and Drug Eluting Stents for Endovascular Treatment of Femoropopliteal Artery Disease
    Haine, Axel
    Schmid, Martin J.
    Schindewolf, Marc
    Lenz, Armando
    Bernhard, Sarah M.
    Drexel, Heinz
    Baumgartner, Iris
    Dopheide, Jorn F.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 58 (06) : 865 - 873
  • [6] Self-expanding nitinol stents: material and design considerations
    Dieter Stoeckel
    Alan Pelton
    Tom Duerig
    European Radiology, 2004, 14 : 292 - 301
  • [7] Self-expanding nitinol stents: material and design considerations
    Stoeckel, D
    Pelton, A
    Duerig, T
    EUROPEAN RADIOLOGY, 2004, 14 (02) : 292 - 301
  • [8] ENDOVASCULAR NITINOL STENTS VERSUS SURGICAL BYPASS IN FEMOROPOPLITEAL LESIONS
    Sarhan, Khalid
    Mohamed, Rashad G.
    Ghanm, Thoria Ibrahim Essa
    Batarseh, Suhel F.
    ATHEROSCLEROSIS, 2024, 399 : 26 - 26
  • [9] A computational study of fatigue resistance of nitinol stents subjected to walk-induced femoropopliteal artery motion
    He, R.
    Zhao, L. G.
    Silberschmidt, V. V.
    Willcock, H.
    JOURNAL OF BIOMECHANICS, 2021, 118
  • [10] Nitinol Stents for Femoropopliteal Disease: What Is the View From the SUMMIT?
    Armstrong, Ehrin J.