Development of a highly-sensitive multi-plex assay using monoclonal antibodies for the simultaneous measurement of kappa and lambda immunoglobulin free light chains in serum and urine

被引:46
|
作者
Campbell, John P. [1 ]
Cobbold, Mark [1 ]
Wang, Yanyun [1 ]
Goodall, Margaret [1 ]
Bonney, Sarah L. [1 ]
Chamba, Anita [1 ]
Birtwistle, Jane [1 ]
Plant, Timothy [1 ]
Afzal, Zaheer [1 ]
Jefferis, Roy [1 ]
Drayson, Mark T. [1 ]
机构
[1] Univ Birmingham, Coll Med & Dent Sci, Sch Immun & Infect, Clin Immunol Serv, Birmingham B15 2TT, W Midlands, England
关键词
Multiple myeloma; Serum free light chains; Bence Jones proteins; Plasma cell dyscrasias; NEPHELOMETRIC ASSAYS; IMMUNOFIXATION; PERFORMANCE; GAMMOPATHY; MYELOMA; ANTIGEN; PATIENT; PREDICT; RISK;
D O I
10.1016/j.jim.2013.01.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Monoclonal kappa and lambda immunoglobulin free light chain (FLC) paraproteins in serum and urine are important markers in the diagnosis and monitoring of B cell dyscrasias. Current nephelometric and turbidimetric methods that use sheep polyclonal antisera to quantify serum FLC have a number of well-observed limitations. In this report, we describe an improved method using specific mouse anti-human FLC monoclonal antibodies (mAbs). Anti-kappa and anti-lambda FLC mAbs were, separately, covalently coupled to polystyrene Xmap (R) beads and assayed, simultaneously, in a multi-plex format by Luminex (R) (mAb assay). The mAbs displayed no cross-reactivity to bound LC, the alternate LC type, or other human proteins and had improved sensitivity and specificity over immunofixation electrophoresis (IFE) and Freelite (TM). The assay gives good linearity and sensitivity (<1 mg/L), and the competitive inhibition format gave a broad calibration curve up to 437.5 mg/L and prevented anomalous results for samples in antigen excess i.e. high FLC levels. The mAbs displayed good concordance with Freelite (TM) for the quantitation of normal polyclonal FLC in plasma from healthy donors (n = 249). The mAb assay identified all monoclonal FLC in serum from consecutive patient samples (n = 1000; 50.1% with monoclonal paraprotein by serum IFE), and all FLC in a large cohort of urine samples tested for Bence Jones proteins (n = 13090; 22.8% with monoclonal kappa, 9.0% with monoclonal lambda, and 0.8% with poly LC detected by urine IFE). Importantly this shows that the mAbs are at least close to the ideal of detecting FLC from all patients and neoplastic plasma cell clones. Given the overall effectiveness of the anti-FLC mAbs, further clinical validation is now warranted on serial samples from a range of patients with B cell disorders. Use of these mAbs on other assay platforms should also be investigated. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 7 条
  • [1] Detection of free kappa and lambda light chains in serum and urine in patients with monoclonal gammopathy.
    Herzog, W
    Hofmann, W
    BLOOD, 2003, 102 (11) : 366B - 366B
  • [2] Highly sensitive, automated immunoassay for immunoglobulin free light chains in serum and urine
    Bradwell, AR
    Carr-Smith, HD
    Mead, GP
    Tang, LX
    Showell, PJ
    Drayson, MT
    Drew, R
    CLINICAL CHEMISTRY, 2001, 47 (04) : 673 - 680
  • [3] Analysis of two assays for serum free light chain kappa and lambda using polyclonal and monoclonal antibodies
    Stojakovic, T.
    Zinke-Cerwenka, W.
    Unteregger, M.
    Truschnig-Wilders, M.
    Linkesch, W.
    ONKOLOGIE, 2012, 35 : 142 - 142
  • [4] Development of a highly sensitive and specific immunoradiometric assay for the measurement of human insulin using monoclonal antibodies.
    Siohan, E
    Allauzen, S
    Mani, JC
    Demuynck, A
    Rousset, M
    Laprade, M
    Bouanani, M
    Pau, B
    Marquet, PY
    CLINICAL CHEMISTRY, 1996, 42 (06) : 575 - 575
  • [5] QUANTITATION OF FREE-KAPPA-LIGHT CHAINS IN SERUM AND URINE USING A MONOCLONAL-ANTIBODY BASED INHIBITION ENZYME-LINKED IMMUNOASSAY
    AXIAK, SM
    KRISHNAMOORTHY, L
    GUINAN, J
    RAISON, RL
    JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 99 (01) : 141 - 147
  • [6] ELISAs for free human immunoglobulin light chains in serum: improvement of assay specificity by using two specific antibodies in a sandwich detection method
    Nakano, T
    Nagata, A
    JOURNAL OF IMMUNOLOGICAL METHODS, 2004, 293 (1-2) : 183 - 189
  • [7] Development of a rapid and quantitative lateral flow assay for the simultaneous measurement of serum κ and λ immunoglobulin free light chains (FLC): inception of a new near-patient FLC screening tool
    Campbella, John P.
    Heaneya, Jennifer L. J.
    Shemar, Meena
    Baldwin, Dene
    Griffin, Ann E.
    Oldridge, Emma
    Goodall, Margaret
    Afzal, Zaheer
    Plant, Tim
    Cobbold, Mark
    Jefferis, Roy
    Jacobs, Joannes F. M.
    Hand, Christopher
    Drayson, Mark T.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (03) : 424 - 434