Analysis of nonstationarity in renal autoregulation mechanisms using time-varying transfer and coherence functions

被引:18
|
作者
Chon, Ki H. [1 ]
Zhong, Yuru [1 ]
Moore, Leon C. [2 ]
Holstein-Rathlou, Niels H. [4 ]
Cupples, William A. [3 ]
机构
[1] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY 11794 USA
[2] SUNY Stony Brook, Dept Physiol & Biophys, Stony Brook, NY 11794 USA
[3] Univ Victoria, Dept Biol, Victoria, BC V8W 2Y2, Canada
[4] Univ Copenhagen, Dept Biomed Sci, Copenhagen, Denmark
关键词
hemodynamics; myogenic; tubuloglomerular feedback; hypertension;
D O I
10.1152/ajpregu.00582.2007
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The extent to which renal blood flow dynamics vary in time and whether such variation contributes substantively to dynamic complexity have emerged as important questions. Data from Sprague-Dawley rats (SDR) and spontaneously hypertensive rats (SHR) were analyzed by time-varying transfer functions (TVTF) and time-varying coherence functions (TVCF). Both TVTF and TVCF allow quantification of nonstationarity in the frequency ranges associated with the autoregulatory mechanisms. TVTF analysis shows that autoregulatory gain in SDR and SHR varies in time and that SHR exhibit significantly more nonstationarity than SDR. TVTF gain in the frequency range associated with the myogenic mechanism was significantly higher in SDR than in SHR, but no statistical difference was found with tubuloglomerular (TGF) gain. Furthermore, TVCF analysis revealed that the coherence in both strains is significantly nonstationary and that low-frequency coherence was negatively correlated with autoregulatory gain. TVCF in the frequency range from 0.1 to 0.3 Hz was significantly higher in SDR (7 out of 7, > 0.5) than in SHR (5 out of 6, < 0.5), and consistent for all time points. For TGF frequency range (0.03-0.05 Hz), coherence exhibited substantial nonstationarity in both strains. Five of six SHR had mean coherence (< 0.5), while four of seven SDR exhibited coherence (< 0.5). Together, these results demonstrate substantial nonstationarity in autoregulatory dynamics in both SHR and SDR. Furthermore, they indicate that the nonstationarity accounts for most of the dynamic complexity in SDR, but that it accounts for only a part of the dynamic complexity in SHR.
引用
收藏
页码:R821 / R828
页数:8
相关论文
共 50 条
  • [1] Estimation of time-varying coherence function using time-varying transfer functions
    Zhao, H
    Lu, S
    Zou, R
    Ju, KW
    Chon, KH
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (11) : 1582 - 1594
  • [2] Estimation of time-varying coherence function using time-varying transfer functions
    Zhao, H
    Zou, R
    Chon, KH
    [J]. PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 298 - 301
  • [3] Estimation of Time-Varying Coherence Function Using Time-Varying Transfer Functions
    He Zhao
    Sheng Lu
    Rui Zou
    Kihwan Ju
    Ki H. Chon
    [J]. Annals of Biomedical Engineering, 2005, 33 : 1582 - 1594
  • [4] Binary QUATRE Using Time-varying Transfer Functions
    Chu, Shu-Chuan
    Zhuang, Zhongjie
    Hu, Chia-Cheng
    Pan, Jeng-Shyang
    [J]. JOURNAL OF INTERNET TECHNOLOGY, 2022, 23 (03): : 425 - 435
  • [5] Estimation of time-varying magnitude squared coherence functions
    Kim, DN
    Cha, IW
    Youn, DH
    [J]. ICICS - PROCEEDINGS OF 1997 INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATIONS AND SIGNAL PROCESSING, VOLS 1-3: THEME: TRENDS IN INFORMATION SYSTEMS ENGINEERING AND WIRELESS MULTIMEDIA COMMUNICATIONS, 1997, : 1389 - 1392
  • [6] Time-varying properties of renal autoregulatory mechanisms
    Zou, R
    Cupples, WA
    Yip, KP
    Holstein-Rathlou, NH
    Chon, KH
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (10) : 1112 - 1120
  • [7] Analysis of renal autoregulatory dynamics using time-varving transfer and coherence functions
    Zhong, YR
    Cupples, WA
    Moore, LC
    Chou, KH
    [J]. FASEB JOURNAL, 2004, 18 (04): : A287 - A288
  • [8] Robust algorithm for estimation of time-varying transfer functions
    Zou, R
    Chon, KH
    [J]. PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2386 - 2389
  • [9] Robust algorithm for estimation of time-varying transfer functions
    Zou, R
    Chon, KH
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (02) : 219 - 228
  • [10] TIME-VARYING INDUCED COHERENCE
    WANG, LJ
    ZOU, XY
    MANDEL, L
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (04) : 605 - 609