2D display of a 3D tree for pulmonary embolism detection

被引:4
|
作者
Kiraly, AP [1 ]
Naidich, DP [1 ]
Novak, CL [1 ]
机构
[1] Siemens Corp Res Inst, Princeton, NJ USA
关键词
pulmonary embolism; computed tomography angiography; vessel segmentation; vessel unfolding;
D O I
10.1016/j.ics.2005.03.348
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The detection of pulmonary emboli (PE) is of critical importance in determining further treatment. PE visualization and detection methods applied to contrast-enhanced computed tomography (CT) images have been shown to facilitate diagnosis. Unfortunately, to date, these methods have imposed significant requirements for 3D navigation and manual vessel tracking. Consequently, we propose a novel method to minimize these requirements by visualizing the entire 3D tree structure within a single, though potentially very large, 2D image. The only navigation that is required is panning through a 2D image, similar to the way that a book is read: from left to right and top to bottom. Vessels are presented in a hierarchical order making them easy to trace, providing a straightforward systematic view of all portions of the vessel tree, without the necessity of viewing areas multiple times or potentially overlooking subtle abnormalities. We present preliminary results using this method. (c) 2005 CARS & Elsevier B.V. All rights reserved.
引用
收藏
页码:1132 / 1136
页数:5
相关论文
共 50 条
  • [1] A comparison of 2D and 3D evaluation methods for pulmonary embolism detection in CT images
    Kiraly, Atilla P.
    Novak, Carol L.
    Naidich, David P.
    Vlahos, Ioannis
    Ko, Jane P.
    Brusca-Augello, Geraldine T.
    MEDICAL IMAGING 2006: IMAGE PERCEPTION, OBSERVER PERFORMANCE AND TECHNOLOGY ASSESSMENT, 2006, 6146
  • [2] 3D Experience on a 2D Display
    Srinath, Raghunandan
    Aishwarya, P.
    Suman, B.
    Ramgopichand, V. N.
    Surabhi, N.
    2021 INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATION AND INFORMATICS (ICCCI), 2021,
  • [3] 3D RECONSTRUCTION OF A 2D VISUAL DISPLAY
    BROWN, LB
    JOURNAL OF GENETIC PSYCHOLOGY, 1969, 115 (02): : 257 - &
  • [4] 2D/3D switchable mobile display
    Wu, Chou-Lin
    Tsai, Chao-Hsu
    Lee, Kuen
    IDMC'07: PROCEEDINGS OF THE INTERNATIONAL DISPLAY MANUFACTURING CONFERENCE 2007, 2007, : 880 - 883
  • [5] The Development of 42" 2D/3D Switchable Display
    Kang, Hoon
    Jang, Mi-Kyoung
    Kim, Kyeong-Jin
    Ahn, Byung-Chul
    Chung, In-Jae
    Park, Tae-Soo
    Chang, Jin-Wook
    Lee, Kyoung-Il
    Kim, Sung-Tae
    JOURNAL OF INFORMATION DISPLAY, 2007, 8 (01) : 22 - 25
  • [6] The development of 42" 2D/3D switchable display
    Kang, H.
    Jang, M. K.
    Kim, K. J.
    Ahn, B. C.
    Yeo, S. D.
    Park, T. S.
    Jang, J. W.
    Lee, K. I.
    Kim, S. T.
    IMID/IDMC 2006: THE 6TH INTERNATIONAL MEETING ON INFORMATION DISPLAY/THE 5TH INTERNATIONAL DISPLAY MANUFACTURING CONFERENCE, DIGEST OF TECHNICAL PAPERS, 2006, : 1311 - 1313
  • [7] Value of 3D right ventricular function over 2D assessment in acute pulmonary embolism
    Moceri, Pamela
    Duchateau, Nicolas
    Sartre, Benjamin
    Baudouy, Delphine
    Squara, Fabien
    Sermesant, Maxime
    Ferrari, Emile
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2021, 38 (10): : 1694 - 1701
  • [8] A 2D/3D compatible display based on polarization modulator
    Lv, Guo-Jiao
    Zhao, Bai-Chuan
    Liu, Ze-Sheng
    Deng, Hui
    Wu, Fei
    OPTIK, 2019, 184 : 485 - 489
  • [9] 2D/3D dual-image switchable display
    Kuo, Wei-Hung
    Chou, Weng-Bing
    Cheng, Tsung-Chin
    Yeh, Pi-Chun
    Jeng, Yue-Shin
    Hu, Chih-Jen
    Huang, Wei-Ming
    2008 SID INTERNATIONAL SYMPOSIUM, DIGEST OF TECHNICAL PAPERS, VOL XXXIX, BOOKS I-III, 2008, 39 : 264 - 266
  • [10] The 3D and 2D color flow display of breast masses
    Carson, PL
    Moskalik, AP
    Govil, A
    Roubidoux, MA
    Fowlkes, JB
    Normolle, D
    Adler, DD
    Rubin, JM
    Helvie, M
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06): : 837 - 849