Correlation Between 2D Passing Rates and 3D Dose Differences for Pretreatment VMAT QA

被引:0
|
作者
Jin, X. [1 ]
Xie, C. [1 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 1, Wenzhou, Peoples R China
关键词
D O I
10.1118/1.4888755
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-422
引用
收藏
页码:323 / 323
页数:1
相关论文
共 50 条
  • [1] A Correlation Study On 3D Fluence-Based QA and 2D Dose Measurement-Based QA
    Liu, S.
    Mazur, T.
    Li, H.
    Green, O.
    Sun, B.
    Mutic, S.
    Yang, D.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3525 - 3526
  • [2] VMAT lung SBRT: 3D evaluation in pretreatment patient QA and in vivo dose verification
    Villaggi, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S744 - S744
  • [3] A Correlation Study of 2D and 3D Gamma Passing Rates for Prostate IMRT Plans
    Zhang, D.
    Wang, B.
    Deng, X.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3335 - 3335
  • [4] On using 3D γ-analysis for IMRT and VMAT pretreatment plan QA
    Wu, Chuan
    Hosier, Kelly E.
    Beck, Kristen E.
    Radevic, Marlyn B.
    Lehmann, Joerg
    Zhang, Hao H.
    Kroner, Aaron
    Dutton, Sharon C.
    Rosenthal, Seth A.
    Bareng, Jonathan K.
    Logsdon, Mark D.
    Asche, David R.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3051 - 3059
  • [5] Individual Volume Based 3D Gamma Indices for Pretreatment VMAT QA
    Jin, X.
    Yi, J.
    Xie, C.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3372 - 3372
  • [6] Comparison of 2D and 3D Gamma Analysis in Patient-Specific QA for Prostate VMAT Plans
    Clemente, F.
    Perez, C.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 240 - +
  • [7] Individual volume-based 3D gamma indices for pretreatment VMAT QA
    Yi, Jinling
    Han, Ce
    Zheng, Xiaomin
    Zhou, Yongqiang
    Deng, Zhenxiang
    Xie, Congying
    Jin, Xiance
    Jin, Fu
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (03): : 28 - 36
  • [8] Understanding the Meaning of IMRT QA Passing Rates with a 2D Diode Array
    Perez-Andujar, A.
    Morin, O.
    Chuang, C.
    Pouliot, J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3731 - 3731
  • [9] Sensitivity analysis of EPID-based 3D dose reconstruction for VMAT QA
    Alhazmi, A.
    Gianoli, C.
    Neppl, S.
    Martins, J.
    Veloza, S.
    Podesta, M.
    Verhaegen, F.
    Reiner, M.
    Belka, C.
    Parodi, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S960 - S961
  • [10] A study on correlation between 2D and 3D gamma evaluation metrics in patient-specific quality assurance for VMAT
    Rajasekaran, Dhanabalan
    Jeevanandam, Prakash
    Sukumar, Prabakar
    Ranganathan, Arulpandiyan
    Johnjothi, Samdevakumar
    Nagarajan, Vivekanandan
    [J]. MEDICAL DOSIMETRY, 2014, 39 (04) : 300 - 308