Etiology of false-positive 18F-FDG PET/CT of mediastinal and hilar lymph nodes with surgical biopsy in cancer patients

被引:0
|
作者
Carvajal, Carlos [1 ]
Naranjo, Monica [2 ]
Carreno, Jose [3 ]
Chinchilla, Luis [4 ]
Alvarado, Fernando [5 ]
Buitrago, Miguel [1 ]
Callejas, Ana [1 ]
Beltran, Rafael [1 ]
机构
[1] Inst Nacl Cancerol, Unidad Func Cirugia Torax, Bogota, Colombia
[2] Inst Nacl Cancerol, Grp Med Nucl, Bogota, Colombia
[3] Inst Nacl Cancerol, Grp Invest Clin Epidemiol Canc, Bogota, Colombia
[4] Ctr Oncol Antioquia, Cirugia Torax, Envigado, Colombia
[5] Univ El Bosque, Cirugia Torax, Bogota, Colombia
来源
REVISTA COLOMBIANA DE CANCEROLOGIA | 2022年 / 26卷 / 04期
关键词
positron emission tomography computed tomography; lymph node excision; mediastinum; anthracosis; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; FDG-PET; ANTHRACOSIS; LYMPHADENOPATHY;
D O I
10.35509/01239015.855
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: This article aimed to describe the etiology of false-positive 18F-FDG PET/CT and its associations with clinical and imaging characteristics in cancer patients undergoing surgical biopsy of mediastinal and hilar lymph nodes at the Instituto Nacional de Cancerologia (INC), Bogota, Colombia, over a period of 8 years. Methods: Retrospective and analytical study. Results: In this study, 93 patients were included with a median age of 64 years (IQR: 55-70), and 57% were women. 35.5% of the patients had lung cancer, followed by lymphoma in 21.5%; 43% of the patients were smokers, and 17.2% had biomass combustion exposure. Of the 93 patients, 220 mediastinal and hilar lymph node stations were biopsied; 37 (16.8%) lymph node stations corresponded to false-positive 18F-FDG PET/CT. The etiology was anthracosis in 19 (51.4%) stations, sarcoidosis in 8 (21.6%) stations, negative for malignancy in 7 (18.9%) stations, and only two stations were granulomas. A statistically significant association was found between false positives and lymph node stations in patients >= 65 years (p=0.008) and patients with a history of smoking (p=0.021). In addition, an association was found between true positives and enlarged lymph nodes (p=0.033). Conclusion: The main etiology of false-positive 18F-FDG PET/CT was anthracosis. In contrast, granulomas were not an important etiology. An association was found between false positives and lymph node stations in patients >= 65 years and patients with a history of smoking. Association was also found between true positives and enlarged lymph nodes in the 18F-FDG PET/CT.
引用
收藏
页码:412 / 419
页数:8
相关论文
共 50 条
  • [1] 18F-FAPI PET/CT performs better in evaluating mediastinal and hilar lymph nodes in patients with lung cancer: comparison with 18F-FDG PET/CT
    Sun, Yuyun
    Sun, Yun
    Li, Zili
    Song, Shaoli
    Wu, Kailiang
    Mao, Jingfang
    Cheng, Jingyi
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2024, 29 (01)
  • [2] 18F-FAPI PET/CT performs better in evaluating mediastinal and hilar lymph nodes in patients with lung cancer: comparison with 18F-FDG PET/CT
    Yuyun Sun
    Yun Sun
    Zili Li
    Shaoli Song
    Kailiang Wu
    Jingfang Mao
    Jingyi Cheng
    European Journal of Medical Research, 29
  • [3] False-Positive Axillary Lymph Nodes Due to Silicone Adenitis on 18F-FDG PET/CT in an Oncological Setting
    D'hulst, Ludovic
    Nicolaij, Daniel
    Beels, Laurence
    Gheysens, Olivier
    Alaerts, Herwig
    Van de Wiele, Christophe
    Maes, Alex
    JOURNAL OF THORACIC ONCOLOGY, 2016, 11 (06) : E73 - E75
  • [4] Supraclavicular Lymph Nodes Detected by 18F-FDG PET/CT in Cancer Patients: Assessment With 18F-FDG PET/CT and Sonography
    Lee, Jae-hoon
    Kim, Jinna
    Moon, Hee Jung
    Cho, Arthur
    Yun, Mijin
    Lee, Jong Doo
    Kang, Won Jun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : 187 - 193
  • [5] Metformine induces false-positive 18F-FDG PET/CT uptake
    Brihaye, Benoit
    Lidove, Olivier
    Lussato, David
    Aparicio, Thomas
    Papo, Thomas
    PRESSE MEDICALE, 2009, 38 (04): : 686 - 687
  • [6] 18F-FDG and 18F-FLT PET/CT imaging in the characterization of mediastinal lymph nodes
    Rayamajhi, Sampanna Jung
    Mittal, Bhagwant Rai
    Maturu, Venkata Nagarjuna
    Agarwal, Ritesh
    Bal, Amanjit
    Dey, Pranab
    Shukla, Jaya
    Gupta, Dheeraj
    ANNALS OF NUCLEAR MEDICINE, 2016, 30 (03) : 207 - 216
  • [7] 18F-FDG and 18F-FLT PET/CT imaging in the characterization of mediastinal lymph nodes
    Sampanna Jung Rayamajhi
    Bhagwant Rai Mittal
    Venkata Nagarjuna Maturu
    Ritesh Agarwal
    Amanjit Bal
    Pranab Dey
    Jaya Shukla
    Dheeraj Gupta
    Annals of Nuclear Medicine, 2016, 30 : 207 - 216
  • [8] What are the Best Ways to Reduce the False-positive Rate of 18F-FDG PET/CT in Patients with Breast Cancer?
    Evangelista, Laura
    Baretta, Zora
    Vinante, Lorenzo
    Sotti, Guido
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 45 (01) : 85 - 86
  • [9] What are the Best Ways to Reduce the False-positive Rate of 18F-FDG PET/CT in Patients with Breast Cancer?
    Laura Evangelista
    Zora Baretta
    Lorenzo Vinante
    Guido Sotti
    Nuclear Medicine and Molecular Imaging, 2011, 45 (1) : 85 - 86
  • [10] False-positive and true-negative hilar and mediastinal lymph nodes on FDG-PET: Radiological-pathological correlation
    Shiraki, N
    Hara, M
    Itoh, M
    Iida, A
    Kohno, T
    Shibamoto, Y
    RADIOLOGY, 2002, 225 : 198 - 198