Near-Infrared Fluorescence Imaging in the Identification of Parathyroid Glands in Thyroidectomy

被引:17
|
作者
Takahashi, Takeshi [1 ]
Yamazaki, Keisuke [1 ]
Ota, Hisayuki [1 ]
Shodo, Ryusuke [1 ]
Ueki, Yushi [1 ]
Horii, Arata [1 ]
机构
[1] Niigata Univ, Grad Sch Med & Dent Sci, Dept Otolaryngol Head & Neck Surg, Niigata, Japan
来源
LARYNGOSCOPE | 2021年 / 131卷 / 05期
关键词
Near-infrared fluorescence imaging; parathyroid gland; thyroidectomy; LOCALIZATION;
D O I
10.1002/lary.29163
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis To assess the ability of near-infrared fluorescence imaging (NIFI) to identify parathyroid glands (PGs) among histologically proven PG/non-PG specimens compared with a surgeon's visual acumen, and to determine NIFI sensitivity in detecting incidentally resected PGs from thyroidectomy specimens, compared to the surgeon's visual inspection. Study Design Prospective study. Methods With mean age of 61 years, 36 patients with various thyroid diseases were enrolled. Possible PGs (n = 28) and lymph nodes (n = 32) were identified by the experienced surgeon's visual inspection. Using NIFI, 15 PGs were further identified from thyroidectomy specimens. For these 75 specimens, the surgeon's judgments (PG vs. non-PG) were recorded. Histological evaluation was performed after examining the NIFI auto-fluorescence of each specimen. Results There were no significant differences in sensitivity, specificity, positive predictive value, and negative predictive value between the surgeon's visual inspection and NIFI in identifying PGs, with values of 100%/97.1%, 85.0%/87.5%, 85.4%/87.2%, and 100%/97.2%, respectively. The sensitivity of NIFI (82.9%) for detection of PGs from thyroidectomy specimens was significantly higher than that of the surgeon's visual inspection (61.0%). False negative specimens contained bleeding/congestion and/or encapsulation by thick tissues, whereas false positive specimens contained electrocoagulated tissues. Conclusions NIFI showed results comparable to the experienced surgeon's visual inspection in identifying PGs. This could benefit novice surgeons. NIFI may be useful for experienced surgeons to locate incidentally resected PGs within thyroidectomy specimens for auto-transplantation. Prevention of intra-gland bleeding and congestion, careful removal of thick capsules, and bloodless surgeries without electrocoagulation are important for reducing false positive and false negative results.Laryngoscope, 2020
引用
收藏
页码:1188 / 1193
页数:6
相关论文
共 50 条
  • [1] In Reference to Near-Infrared Fluorescence Imaging in the Identification of Parathyroid Glands in Thyroidectomy
    Wang, Bin
    Zhu, Chun-Rong
    Wu, Jian
    LARYNGOSCOPE, 2021, 131 (05): : E1748 - E1748
  • [2] Intraoperative near-infrared autofluorescence imaging of parathyroid glands
    Ladurner, Roland
    Sommerey, Sandra
    Al Arabi, Nora
    Hallfeldt, Klaus K. J.
    Stepp, Herbert
    Gallwas, Julia K. S.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (08): : 3140 - 3145
  • [3] Intraoperative near-infrared autofluorescence imaging of parathyroid glands
    Roland Ladurner
    Sandra Sommerey
    Nora Al Arabi
    Klaus K. J. Hallfeldt
    Herbert Stepp
    Julia K. S. Gallwas
    Surgical Endoscopy, 2017, 31 : 3140 - 3145
  • [4] Analysis of near-infrared autofluorescence imaging for detection of inadvertently resected parathyroid glands after endoscopic thyroidectomy
    Kuo, Ting-Chun
    Chen, Kuen-Yuan
    Lai, Chieh-Wen
    Lin, Ming-Tsan
    Chang, Chin-Hao
    Wu, Ming-Hsun
    EJSO, 2024, 50 (11):
  • [5] Near infrared fluorescence imaging of rabbit thyroid and parathyroid glands
    Antakia, Ramez
    Gayet, Pascal
    Guillermet, Stephanie
    Stephenson, Tim J.
    Brown, Nicola J.
    Harrison, Barney J.
    Balasubramanian, Saba P.
    JOURNAL OF SURGICAL RESEARCH, 2014, 192 (02) : 480 - 486
  • [6] Fluorescence intensity of parathyroid glands in thyroid and parathyroid surgery: a near-infrared autofluorescence study
    Yu, Fan
    Yi, Xiaolei
    Lin, Zihan
    Wu, Yinyue
    Luo, Quanyong
    Wu, Bo
    FRONTIERS IN SURGERY, 2025, 12
  • [7] Comparison of indocyanine green fluorescence and parathyroid autofluorescence imaging in the identification of parathyroid glands during thyroidectomy
    Kahramangil, Bora
    Berber, Eren
    GLAND SURGERY, 2017, 6 (06) : 644 - 648
  • [8] Near-infrared fluorescence in robotic thyroidectomy
    Muraveika, Liudmila
    Kose, Emin
    Berber, Eren
    GLAND SURGERY, 2020, 9 : S147 - S152
  • [9] A multicenter evaluation of near-infrared autofluorescence imaging of parathyroid glands in thyroid and parathyroid surgery
    Sehnem, Ludovico, Jr.
    Noureldine, Salem, I
    Avci, Seyma
    Isiktas, Gizem
    Elshamy, Mohammed
    Saito, Yoshiyuki
    Ahmed, Amr H. A.
    Tierney, Hien T.
    Trinh, Lily N.
    Karcioglu, Amanda Silver
    Cheung, Anthony Y.
    Otremba, Michael
    Krishnamurthy, Vikram
    Heiden, Katherine
    Jin, Judy
    Shin, Joyce
    Siperstein, Allan
    Zafereo, Mark
    Tufano, Ralph P.
    Randolph, Gregory W.
    Kebebew, Electron
    Milas, Mira
    Duh, Quan-Yang
    Berber, Eren
    SURGERY, 2023, 173 (01) : 132 - 137
  • [10] The impact of near infrared fluorescence imaging on parathyroid function after total thyroidectomy
    Kim, Yoo Seok
    Erten, Ozgun
    Kahramangil, Bora
    Aydin, Husnu
    Donmez, Mustafa
    Berber, Eren
    JOURNAL OF SURGICAL ONCOLOGY, 2020, 122 (05) : 973 - 979