Objective: To present the results following a UK national patient dose audit of paediatric CT examinations, to propose updated UK national diagnostic reference levels (DRLs) and to analyse current practice to see if any recommendations can be made to assist with optimisation.Methods: A UK national dose audit was undertaken in 2019 focussing on paediatric CT examinations of the head, chest, abdomen/pelvis and cervical spine using the methods proposed by the International Commission on Radiological Protection. The audit pro-forma contained mandatory fields, of which the post-examination dosimetry (volume CT dose index and dose-length product) and the patient weight (for body examinations) were the most important.Results: Analysis of the data submitted indicates that it is appropriate to propose national DRLs for CT head examinations in the 0-<1, 1-<5, 5-<10 and 10-<15 year age ranges. This extends the number of age categories of national DRLs from those at present and revises the existing values downwards. For CT chest examinations, it is appropriate to propose national DRLs for the first time in the UK for the 5-<15, 15-<30, 30-<50 and 50-<80 kg weight ranges. There were insufficient data received to propose national DRLs for abdomen/pelvis or cervical spine examinations. Recommendations towards optimisation focus on the use of tube current (mA) modulation, iterative reconstruction and the selection of examination tube voltage (kVp).Conclusion: Updated UK national DRLs are proposed for paediatric CT examinations of the head and chest.Advances in knowledge: A national patient dose audit of paediatric CT examinations has led to the proposal of updated national DRLs.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Patient dose audit in common CT examinations
    Dimitroukas, Christos P.
    Metaxas, Vasileios I.
    Efthymiou, Fotios O.
    Kalogeropoulou, Christina P.
    Zampakis, Petros E.
    Panayiotakis, George S.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 192
  • [2] Establishing the UK National Paediatric Diabetes Audit
    Smith, AHK
    [J]. DIABETES NUTRITION & METABOLISM, 2001, 14 (02) : 107 - 110
  • [3] Establishing a national UK paediatric diabetes audit
    Smith, AHK
    Roxburgh, MA
    [J]. DIABETOLOGIA, 2000, 43 : A71 - A71
  • [4] ASSESSMENT OF EFFECTIVE DOSE IN PAEDIATRIC CT EXAMINATIONS
    Dougeni, E.
    Chapple, C. L.
    Willis, J.
    Panayiotakis, G.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) : 147 - 150
  • [5] Hereditary angioedema - results from a UK national audit
    Jolles, S.
    [J]. ALLERGY, 2012, 67 : 84 - 85
  • [6] National audit on the appropriateness of CT and MRI examinations in Luxembourg
    Aurélien Bouëtté
    Alexandra Karoussou-Schreiner
    Hubert Ducou Le Pointe
    Martijn Grieten
    Eric de Kerviler
    Léon Rausin
    Jean-Christophe Bouëtté
    Patrick Majerus
    [J]. Insights into Imaging, 10
  • [7] National audit on the appropriateness of CT and MRI examinations in Luxembourg
    Bouette, Aurelien
    Karoussou-Schreiner, Alexandra
    Le Pointe, Hubert Ducou
    Grieten, Martijn
    de Kerviler, Eric
    Rausin, Leon
    Bouette, Jean-Christophe
    Majerus, Patrick
    [J]. INSIGHTS INTO IMAGING, 2019, 10 (01)
  • [8] A National Audit of Paediatric to Adult Transition Liver Services in the UK
    Samyn, Marianne
    Dyson, Jessica
    Hudson, Mark
    Levitsky, Josh
    Heldman, Madeleine
    Joshi, Deepak
    [J]. HEPATOLOGY, 2018, 68 : 315A - 316A
  • [9] Comprehensive audit of brachytherapy dose distributions: A methodology and UK audit results
    Palmer, A. L.
    Bradley, D.
    Nisbet, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S150 - S151
  • [10] A dose audit of fluoroscopy examinations at Charlotte Maxeke Johannesburg Academic Hospital: Analysis of preliminary results
    Nyathi, T.
    Pule, M. L.
    Segone, P.
    van der Merwe, D. G.
    Rapoho, S. P.
    [J]. SA JOURNAL OF RADIOLOGY, 2009, 13 (02): : 24 - 28