Multi-reference global registration of individual A-lines in adaptive optics optical coherence tomography retinal images

被引:22
|
作者
Kurokawa, Kazuhiro [1 ]
Crowell, James A. [1 ]
Do, Nhan [2 ,3 ]
Lee, John J. [2 ]
Miller, Donald T. [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
[2] Indiana Univ Purdue Univ, Purdue Sch Engn & Technol, Indianapolis, IN 46202 USA
[3] Google, Mountain View, CA 94043 USA
关键词
three-dimensional registration; image registration; adaptive optics; optical coherence tomography; parallel processing; CONE PHOTORECEPTORS; MOTION CORRECTION; EYE-MOVEMENTS; RESOLUTION; DEPTH; CELLS;
D O I
10.1117/1.JBO.26.1.016001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: Adaptive optics optical coherence tomography (AO-OCT) technology enables non-invasive, high-resolution three-dimensional (3D) imaging of the retina and promises earlier detection of ocular disease. However, AO-OCT data are corrupted by eye-movement artifacts that must be removed in post-processing, a process rendered time-consuming by the immense quantity of data. Aim: To efficiently remove eye-movement artifacts at the level of individual A-lines, including those present in any individual reference volume. Approach: We developed a registration method that cascades (1) a 3D B-scan registration algorithm with (2) a global A-line registration algorithm for correcting torsional eye movements and image scaling and generating global motion-free coordinates. The first algorithm corrects 3D translational eye movements to a single reference volume, accelerated using parallel computing. The second algorithm combines outputs of multiple runs of the first algorithm using different reference volumes followed by an affine transformation, permitting registration of all images to a global coordinate system at the level of individual A-lines. Results: The 3D B-scan algorithm estimates and corrects 3D translational motions with high registration accuracy and robustness, even for volumes containing microsaccades. Averaging registered volumes improves our image quality metrics up to 22 dB. Implementation in CUDA (TM) on a graphics processing unit registers a 512 x 512 x 512 volume in only 10.6 s, 150 times faster than MATLAB (TM) on a central processing unit. The global A-line algorithm minimizes image distortion, improves regularity of the cone photoreceptor mosaic, and supports enhanced visualization of low-contrast retinal cellular features. Averaging registered volumes improves our image quality up to 9.4 dB. It also permits extending the imaging field of view (similar to 2.1x) and depth of focus (similar to 5.6x) beyond what is attainable with single-reference registration. Conclusions: We can efficiently correct eye motion in all 3D at the level of individual A-lines using a global coordinate system. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:29
相关论文
共 50 条
  • [1] Segmentation-Based Registration of Volumetric Images Acquired With Adaptive Optics Optical Coherence Tomography
    Lee, S.
    Kocaoglu, O. P.
    Wang, Q.
    Jonnal, R. S.
    Gao, W.
    Miller, D. T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [2] Adaptive optics optical coherence tomography with dynamic retinal tracking
    Kocaoglu, Omer P.
    Ferguson, R. Daniel
    Jonnal, Ravi S.
    Liu, Zhuolin
    Wang, Qiang
    Hammer, Daniel X.
    Miller, Donald T.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (07): : 2262 - 2284
  • [3] Adaptive optics optical coherence tomography for in vivo mouse retinal imaging
    Jian, Yifan
    Zawadzki, Robert J.
    Sarunic, Marinko V.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
  • [4] Automated Vessel Segmentation in Adaptive Optics - Optical Coherence Tomography Images
    Le, Christopher
    Wang, Dongyi
    Villanueva, Ricardo
    Liu, Zhuolin
    Hammer, Daniel
    Saeedi, Osamah
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [5] Reflective Afocal Adaptive Optics - Optical Coherence Tomography Retinal Imaging System
    Lee, Sang Hyuck
    Werner, John S.
    Zawadzki, Robert J.
    OPHTHALMIC TECHNOLOGIES XXIII, 2013, 8567
  • [6] Retinal imaging with polarization-sensitive optical coherence tomography and adaptive optics
    Cense, Barry
    Gao, Weihua
    Brown, Jeffrey M.
    Jones, Steven M.
    Jonnal, Ravi S.
    Mujat, Mircea
    Park, B. Hyle
    de Boer, Johannes F.
    Miller, Donald T.
    OPTICS EXPRESS, 2009, 17 (24): : 21634 - 21651
  • [7] Retinal Imaging with a Combined Adaptive Optics - Optical Coherence Tomography and Adaptive Optics - Scanning Laser Ophthalmoscopy System
    Zawadzki, Robert J.
    Jones, Steven M.
    Pilli, Suman
    Kim, Dae Yu
    Olivier, Scot S.
    Werner, John S.
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [8] Combined Adaptive Optics - Optical Coherence Tomography and Adaptive Optics - Scanning Laser Ophthalmoscopy system for retinal imaging
    Zawadzki, Robert J.
    Jones, Steven M.
    Chen, Diana
    Choi, Stacey S.
    Evans, Julia W.
    Olivier, Scot S.
    Werner, John S.
    OPHTHALMIC TECHNOLOGIES XIX, 2009, 7163
  • [9] Retinal imaging with adaptive optics high speed and high resolution optical coherence tomography
    Zawadzki, RJ
    Laut, S
    Zhao, M
    Jones, S
    Olivier, S
    Izatt, JA
    Werner, JS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [10] Retinal epi-vascular structures as seen by adaptive optics optical coherence tomography
    Pircher, Michael
    Brunner, Elisabeth
    Kunze, Laura Eva
    Schmidt-Erfurth, Ursula
    Drexler, Wolfgang
    Pollreisz, Andreas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)