Prediction of recurrence after cryoballoon ablation therapy in patients with paroxysmal atrial fibrillation

被引:5
|
作者
Lewicka, Ewa [1 ]
机构
[1] Med Univ Gdansk, Dept Cardiol & Electrotherapy, Debinki 7, PL-80952 Gdansk, Poland
来源
ANATOLIAN JOURNAL OF CARDIOLOGY | 2016年 / 16卷 / 07期
关键词
PULMONARY VEIN ISOLATION; CATHETER ABLATION; DYSSYNCHRONY; PERSISTENT; VOLUME; TIME;
D O I
10.14744/AnatolJCardiol.2016.19024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The purpose of this study was to investigate the factors predicting the maintenance of sinus rhythm in patients with paroxysmal atrial fibrillation (PAF) who underwent cryoablation of the pulmonary veins (PVs). Methods: Fifty-one patients (54.6 +/- 10.4 years) with paroxysmal AF who underwent the cryoablation of the PVs were to the prospective trial. The clinical risk factors and echocardiographic parameters [left atrial (LA) diameter, left ventricular ejection fraction and dimensions, left atrial spontaneous echo contrast (LASEC), mitral annulus calcification (MAC), left atrial appendage emptying peak flow velocity (LAAV), and PV flow] were assessed before the cryoablation procedure. Patients with PAF who refused to use any medication because of intolerance or presentation of resistant symptoms, despite the use of at least one antiarrhythmic drug were enrolled to the study, patients with LA/LAA thrombus on echocardiographic examination, severe valvular disease, pericardial fluid, and abnormal thyroid function tests as well as systemic disease were excluded from the study. All parameters were tested for their ability to predict the recurrence of AF during a 1-year follow-up period. Results: During the period of follow-up, AF recurred in 16 of 51 patients (31.3%/year). All significant parameters associated with the recurrence of AF were evaluated in multivariate logistic regression analysis. The presence of MAC (p<0.001) as well as LA diameter (p<0.0001), LAAV of <30 cm/s (p<0.0001), PV flow systolic wave velocity (p<0.0001), and LASEC (p<0.0001) were detected as independent predictors of recurrence. In the receiver operating characteristic analysis, LAAV of >30 cm/s had a sensitivity of 85% and a specificity of 95% for predicting success after ablation (AUC= 0.813; 95% CI: 0.76-0.92; p<0.0001). Conclusion: The presence of MAC, increased LA diameter, the existence of LASEC, low LAAV, and low peak PV systolic wave velocity are parameters that can predict the recurrence of AF after cryoablation.
引用
收藏
页码:489 / 490
页数:2
相关论文
共 50 条
  • [1] Risk factors for atrial fibrillation recurrence after cryoballoon catheter ablation in patients with paroxysmal atrial fibrillation
    Zhou, Jin
    Xu, Jing
    Sun, Shan
    Cheng, Aijuan
    Li, Peng
    Ding, Jun
    Yang, Peigen
    Zhang, Zhiyuan
    Fang, Tao
    Yan, Yingchuan
    Cong, Hongliang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (10): : 11205 - 11210
  • [2] Effect of cryoballoon ablation parameters on recurrence in patients with paroxysmal atrial fibrillation
    Demirtas, Abdullah Orhan
    Icen, Yahya Kemal
    Donmez, Yurdaer
    Koca, Hasan
    Kaypakli, Onur
    Sahin, Durmus Yildiray
    Koc, Mevlut
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2019, 47 (06): : 440 - 448
  • [3] Predictive value of HMGB1 for atrial fibrillation recurrence after cryoballoon ablation in paroxysmal atrial fibrillation patients
    Li, Xinxin
    Zhao, Cuiting
    Li, Meng
    Yu, Hongxiao
    Liu, Xiping
    Zhu, Qing
    Song, Xiaokun
    Wang, Yonghuai
    Yu, Bo
    Ma, Chunyan
    CLINICAL CARDIOLOGY, 2022, 45 (12) : 1229 - 1235
  • [4] Atrial tachycardia after cryoballoon ablation of paroxysmal atrial fibrillation
    Wojcik, Maciej
    Berkowitsch, Alexander
    Pitschner, Heinz F.
    Kuniss, Malte
    Neumann, Thomas
    EUROPACE, 2014, 16 (02): : 306 - 306
  • [5] Association of left atrial wall thickness with recurrence after cryoballoon ablation of paroxysmal atrial fibrillation
    Bai, Yixuan
    Jia, Ruikun
    Wang, Xinmeng
    Chan, Juan
    Cui, Kaijun
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (03) : 657 - 667
  • [6] Association of left atrial wall thickness with recurrence after cryoballoon ablation of paroxysmal atrial fibrillation
    Yixuan Bai
    Ruikun Jia
    Xinmeng Wang
    Juan Chan
    Kaijun Cui
    Journal of Interventional Cardiac Electrophysiology, 2024, 67 : 657 - 667
  • [7] The role of left atrial deformation parameters in the prediction of atrial fibrillation recurrence after cryoballoon ablation therapy
    Oncel, Can Ramazan
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2016, 16 (04):
  • [8] Is the time of atrial fibrillation recurrence after cryoballoon ablation of paroxysmal atrial fibrillation influenced by the pattern of PV reconnections?
    Marcus Wieczorek
    Kiarash Sassani
    Reinhard Hoeltgen
    Journal of Interventional Cardiac Electrophysiology, 2021, 60 : 321 - 327
  • [9] Is the time of atrial fibrillation recurrence after cryoballoon ablation of paroxysmal atrial fibrillation influenced by the pattern of PV reconnections?
    Wieczorek, Marcus
    Sassani, Kiarash
    Hoeltgen, Reinhard
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (02) : 321 - 327
  • [10] Predictors of atrial fibrillation recurrence after atrial fibrillation ablation with cryoballoon
    Evranos, Banu
    Aytemir, Kudret
    Oto, Ali
    Okutucu, Sercan
    Karakulak, Ugur
    Sahiner, Levent
    Kaya, Baris
    Kabakci, Giray
    CARDIOLOGY JOURNAL, 2013, 20 (03) : 294 - 303