Prolonged degradation and reliability assessment of installed modules operational for 10 years in 5 MW PV plant in hot semi-arid climate

被引:9
|
作者
Bansal, Neha [1 ]
Jaiswal, Shiva Pujan [1 ]
Singh, Gajendra [2 ]
机构
[1] Sharda Univ, Sch Engn & Technol, Greater Noida, India
[2] ABES Engn Coll, Dept Elect & Elect Engn, Ghaziabad, India
关键词
FMECA; I-V characterization; PV degradation; Solar Photovoltaic; Reliability; Visual inspection; PHOTOVOLTAIC MODULES; PERFORMANCE DEGRADATION; SILICON; SI; TECHNOLOGIES;
D O I
10.1016/j.esd.2022.04.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The current work presents detailed degradation and reliability assessment of installed PV modules in grid tied 5 MW solar PV plant in hot semi-arid climate. Defects and failures of 336 modules out of 2078 visually inspected c-Si modules with 10 years of operational period in hot semi-arid climate is evaluated using FMECA statistical tool and I-V curve measurement. The novelty of the research conducted is presenting long term degradation of PV modules in utility scale PV plant installed for 10 years in outdoor environment in remote location, carrying FMECA analysis of visually degraded modules along with on -field electrical characterization. Correlation of identified defect and failures with electrical parameters of PV module is also presented. The results obtained indicate light and dark EVA discoloration, EVA discoloration with cell and metallization discoloration, snail trails, backsheet burnt, glass breakage with or without cell cracks to be the most dominant and frequently occurring defects and failures with high severity. The inspected plant has considerable degradation as compared to other plants in the same area in hot semi-arid climate and therefore degradation investigation of the plant is important in identifying various possible causes of observed degradation and studying impact of degradation on module performance. Based on the results obtained and analysis conducted, several important preventive and corrective measures along with important recommendations have been enlisted for mitigating failures and improving the system performance.(c) 2022 International Energy Initiative. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:373 / 389
页数:17
相关论文
共 5 条
  • [1] Data of a PV plant implemented in hot semi-arid climate
    Omar, Nour-eddine Id
    Boukhattem, Lahcen
    Hassani, Fahd Oudrhiri
    Bennouna, Amin
    Oukennou, Aziz
    DATA IN BRIEF, 2021, 34
  • [2] Analytical assessment of Ain Skhouna PV plant performance connected to the grid under a semi-arid climate in Algeria
    Ihaddadene, Razika
    Jed, Mohamed El Hassen
    Ihaddadene, Nabila
    De Souza, Amaury
    SOLAR ENERGY, 2022, 232 : 52 - 62
  • [3] Long-term outdoor performance and degradation evaluation of CIS PV plant under the semi-arid climate of Benguerir Morocco
    Elhamaoui, Said
    Benazzouz, Aboubakr
    Elamim, Abderrazzak
    Abdelmoula, Ibtihal Ait
    Tijani, Khalil
    Ghennioui, Abdellatif
    El Khaili, Mohamed
    ENERGY REPORTS, 2023, 9 : 322 - 339
  • [4] Long-term outdoor performance and degradation evaluation of CIS PV plant under the semi-arid climate of Benguerir Morocco
    Elhamaoui, Said
    Benazzouz, Aboubakr
    Elamim, Abderrazzak
    Abdelmoula, Ibtihal Ait
    Tijani, Khalil
    Ghennioui, Abdellatif
    El Khaili, Mohamed
    ENERGY REPORTS, 2023, 9 : 322 - 339
  • [5] Assessment of effects of two runoff control engineering practices on soil water and plant growth for afforestation in a semi-arid area after 10 years
    Zhang, Fu
    Xing, Zisheng
    Rees, Herb W.
    Dong, Yanli
    Li, Sheng
    Meng, Fanrui
    ECOLOGICAL ENGINEERING, 2014, 64 : 430 - 442