Feasibility and safety of high-power ablation of atrial fibrillation with contact force-sensing catheter: The lesion size index-guided ablation

被引:2
|
作者
Parwani, Abdul Shokor [1 ]
Hohendanner, Felix [1 ]
Kluck, Amelie [1 ]
Blaschke, Florian [1 ]
Pieske, Burkert [1 ]
Boldt, Leif-Hendrik [1 ]
机构
[1] Charite Univ Med Berlin, Campus Virchow Klinikum, Berlin, Germany
来源
关键词
atrial fibrillation; high-power ablation; lesion size index; contact force sensing; PULMONARY VEIN ISOLATION; SHORT-DURATION ABLATION;
D O I
10.17219/acem/146917
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background. Radiofrequency (RF) ablation is a commonly used method of atrial fibrillation (AF) treatment. High-power short-duration (HPSD) ablation has been suggested as a method to reduce procedure times whilst creating safe and lasting lesions. High-power ablation with contact force (CF)-sensing technology catheters might aid in a further improvement of safety whilst generating lasting transmural lesions. Objectives. We report our experience using lesion size index (LSI)-guided 50 W ablation with a CF-sensing catheter of AF. Materials and methods. We performed LSI-guided 50 W point-by-point ablation using a CF-sensing catheter (TactiCath). Target LSI at the anterior left atrium (LA) was 5.0 and at the posterior LA it was 4.5. Results. Altogether, 4641 RF lesions were created in 86 consecutive patients. To reach a mean LSI of 4.9 +/- 0.01, a mean RF ablation time of 14.3 +/- 0.1 s was applied with a mean CF of 13.4 +/- 0.1 g. The RF time per lesion at the anterior wall of LA was 15.9 +/- 0.2 s, while it was 13 +/- 0.2 s at the posterior wall of LA. We observed force time integral (FTI) values between 36 g and 310 g. Procedure duration was 107 +/- 4 min with a RF ablation time of 15.4 +/- 0.6 min. No audible steam pops occurred. No pericardial effusion was observed. After a 1-year follow-up, no adverse events were reported and 83% of patients had no symptomatic arrhythmia recurrence. Conclusions. We provide evidence for the safety and efficacy of LSI-guided 50 W ablation using the TactiCath CF-sensing ablation catheter. These data support the use of high-power ablation with CF sensing technology to improve both safety and efficacy.
引用
收藏
页码:715 / 721
页数:7
相关论文
共 50 条
  • [1] Safety and efficacy of ablation index-guided high-power ablation for the treatment of atrial fibrillation
    Zhu, Jing
    Lin, Xian-he
    HELIYON, 2023, 9 (04)
  • [2] Lesion Size Index-guided high-power ablation for atrial fibrillation: Opening the therapeutic window
    Hanley, Alan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (05) : 1312 - 1313
  • [3] First clinical experience of high-power ablation of atrial fibrillation with a novel contact force-sensing gold-tip catheter
    Parwani, Abdul Shokor
    Jayanata, Adrian
    Kraft, Robin
    Lacour, Phillip
    Blaschke, Florian
    Pieske, Burkert
    Boldt, Leif-Hendrik
    CARDIOLOGY JOURNAL, 2022, 29 (05) : 759 - 765
  • [4] Ablation index-guided high-power ablation for superior vena cava isolation in patients with atrial fibrillation
    Cui, Luqian
    Cui, Shihua
    Dong, Shujuan
    Li, Jingchao
    Yu, Haijia
    Song, Huihui
    Han, Yongmei
    Chu, Yingjie
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [5] Safety and efficacy of ablation index-guided atrial fibrillation ablation in octogenarians
    Okamatsu, Hideharu
    Okumura, Ken
    Onishi, Fumitaka
    Yoshimura, Akino
    Negishi, Kodai
    Tsurugi, Takuo
    Tanaka, Yasuaki
    Nakao, Koichi
    Sakamoto, Tomohiro
    Koyama, Junjiro
    CLINICAL CARDIOLOGY, 2023, 46 (07) : 794 - 800
  • [6] Comparison of lesion characteristics between conventional and high-power short-duration ablation using contact force-sensing catheter in patients with paroxysmal atrial fibrillation
    Chun-Chao Chen
    Po-Tseng Lee
    Vu Van Ba
    Chieh-Mao Chuang
    Yenn-Jiang Lin
    Li-Wei Lo
    Yu-Feng Hu
    Fa-Po Chung
    Chin-Yu Lin
    Ting-Yung Chang
    Jennifer Jeanne Vicera
    Ting-Chun Huang
    Chih-Min Liu
    Cheng-I Wu
    Isaiah C. Lugtu
    Ankit Jain
    Shih-Lin Chang
    Shih-Ann Chen
    BMC Cardiovascular Disorders, 21
  • [7] Comparison of lesion characteristics between conventional and high-power short-duration ablation using contact force-sensing catheter in patients with paroxysmal atrial fibrillation
    Chen, Chun-Chao
    Lee, Po-Tseng
    Vu Van Ba
    Chuang, Chieh-Mao
    Lin, Yenn-Jiang
    Lo, Li-Wei
    Hu, Yu-Feng
    Chung, Fa-Po
    Lin, Chin-Yu
    Chang, Ting-Yung
    Vicera, Jennifer Jeanne
    Huang, Ting-Chun
    Liu, Chih-Min
    Wu, Cheng-, I
    Lugtu, Isaiah C.
    Jain, Ankit
    Chang, Shih-Lin
    Chen, Shih-Ann
    BMC CARDIOVASCULAR DISORDERS, 2021, 21 (01)
  • [8] Efficacy and safety of ablation index-guided catheter ablation for atrial fibrillation: an updated meta-analysis
    Ioannou, Adam
    Papageorgiou, Nikolaos
    Lim, Wei Yao
    Wongwarawipat, Tanakal
    Hunter, Ross J.
    Dhillon, Gurpreet
    Schilling, Richard J.
    Creta, Antonio
    El Haddad, Milad
    Duytschaever, Matthias
    Hussein, Ahmed
    Dhiraj, Gupta
    Ahsan, Syed
    Providencia, Rui
    EUROPACE, 2020, 22 (11): : 1659 - 1671
  • [9] Effectiveness and Safety of High-Power Radiofrequency Ablation Guided by Ablation Index for the Treatment of Atrial Fibrillation
    Zhu, Xuefeng
    Wang, Chunxiao
    Chu, Hongxia
    Li, Wenjing
    Zhou, Huihui
    Zhong, Lin
    Li, Jianping
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2022, 2022
  • [10] Unipolar Electrogram-Guided versus Lesion Size Index-Guided Catheter Ablation in Patients with Paroxysmal Atrial Fibrillation
    Fu, Guohua
    He, Bin
    Wang, Binhao
    Feng, Mingjun
    Du, Xianfeng
    Liu, Jing
    Yu, Yibo
    Gao, Fang
    Zhuo, Weidong
    Xu, Yi
    Qi, Yingbo
    Chu, Huimin
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (07)