Divertor impurity monitor for the International Thermonuclear Experimental Reactor

被引:11
|
作者
Sugie, T [1 ]
Ogawa, H
Nishitani, T
Kasai, S
Katsunuma, J
Maruo, M
Ebisawa, K
Ando, T
Kita, Y
机构
[1] Japan Atom Energy Res Inst, Naka, Ibaraki 3110193, Japan
[2] Nikon Inc, Shinagawa Ku, Tokyo, Japan
[3] ITER, Joint Cent Team, San Diego Joint Work Site, La Jolla, CA 92037 USA
[4] ITER, Joint Cent Team, Garching Joint Work Site, Garching, Germany
[5] Toshiba Co Ltd, Fuchu, Tokyo, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1999年 / 70卷 / 01期
关键词
D O I
10.1063/1.1149340
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The divertor impurity monitoring system of the International Thermonuclear Experimental Reactor has been designed. The main functions of this system are to identify impurity species and to measure the two-dimensional distributions of the particle influxes in the divertor plasmas. The wavelength range is 200-1000 nm. The viewing fans are realized by molybdenum mirrors located in the divertor cassette. With additional viewing fans seeing through the gap between the divertor cassettes, the region approximately from the divertor leg to the x point will be observed. The light from the divertor region passes through the quartz windows on the divertor port plug and the cryostat, and goes through the dog-leg optics in the biological shield. Three different type of spectrometers: (i) survey spectrometers for impurity species monitoring, (ii) filter spectrometers for the particle influx measurement with the spatial resolution of 10 mm and the time resolution of 1 ms, and (iii) high dispersion spectrometers for high resolution wavelength measurements are designed. These spectrometers are installed just behind the biological shield (for lambda < 450 nm) to prevent the transmission loss in fiber and in the diagnostic room (for lambda greater than or equal to 450 nm) from the point of view of accessibility and flexibility. The optics have been optimized by a ray trace analysis. As a result, 10-15 mm spatial resolution will be achieved in all regions of the divertor. (C) 1999 American Institute of Physics. [S0034-6748(99)59901- 2].
引用
下载
收藏
页码:351 / 354
页数:4
相关论文
共 50 条
  • [1] Divertor impurity monitor for the international thermonuclear experimental reactor
    Sugie, T.
    Ogawa, H.
    Nishitani, T.
    Kasai, S.
    Katsunuma, J.
    Maruo, M.
    Ebisawa, K.
    Ando, T.
    Kita, Y.
    Review of Scientific Instruments, 1999, 70 (1 pt 2):
  • [2] EROSION REDEPOSITION ANALYSIS OF THE INTERNATIONAL THERMONUCLEAR EXPERIMENTAL REACTOR DIVERTOR
    BROOKS, JN
    FUSION TECHNOLOGY, 1990, 18 (02): : 239 - 250
  • [3] Tritium permeation and inventory in an international thermonuclear experimental reactor divertor
    Shu, WM
    Watanabe, K
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1997, 15 (01): : 169 - 175
  • [4] Multiplexing thermography for International Thermonuclear Experimental Reactor divertor targets
    Itami, K
    Sugie, T
    Vayakis, G
    Walker, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 4124 - 4128
  • [5] A novel digital neutron flux monitor for international thermonuclear experimental reactor
    Zhou, Xiang
    Liu, Zihao
    Chen, Chao
    Zhu, Renjie
    Zhao, Li
    Wei, Lingfeng
    Yin, Zejie
    PLASMA SCIENCE & TECHNOLOGY, 2018, 20 (06)
  • [6] Neutron monitor using microfission chambers for the international Thermonuclear Experimental Reactor
    Nishitani, T
    Kasai, S
    Johnson, LC
    Ebisawa, K
    Walker, C
    Ando, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 1141 - 1144
  • [7] A novel digital neutron flux monitor for international thermonuclear experimental reactor
    周翔
    刘子豪
    陈超
    朱仁杰
    赵丽
    魏凌峰
    阴泽杰
    Plasma Science and Technology, 2018, (06) : 198 - 203
  • [8] Neutron monitor using microfission chambers for the International Thermonuclear Experimental Reactor
    Nishitani, T.
    Kasai, S.
    Johnson, L.C.
    Ebisawa, K.
    Walker, C.
    Ando, T.
    Review of Scientific Instruments, 1999, 70 (1 II): : 1141 - 1144
  • [9] Neutron monitor using microfission chambers for the International Thermonuclear Experimental Reactor
    Nishitani, T.
    Kasai, S.
    Johnson, L.C.
    Ebisawa, K.
    Walker, C.
    Ando, T.
    Review of Scientific Instruments, 1999, 70 (1 pt 2):
  • [10] A novel digital neutron flux monitor for international thermonuclear experimental reactor
    周翔
    刘子豪
    陈超
    朱仁杰
    赵丽
    魏凌峰
    阴泽杰
    Plasma Science and Technology, 2018, 20 (06) : 198 - 203