Applications of continuum fatigue risk monitoring in riser connectors system integrity management

被引:2
|
作者
Yan, Yifei [1 ,4 ]
Zhang, Shengyue [1 ,4 ]
Jin, Xin [2 ]
Xu, Liangbin [3 ]
Yan, Xiangzhen [1 ,4 ]
机构
[1] China Univ Petr East China, Coll Mech & Elect Engn, Qingdao 266580, Shandong, Peoples R China
[2] Jianhu Cty Yongwei Valve Drilling Parts Co Ltd Ya, Yancheng, Jiangsu, Peoples R China
[3] China CNOOC Res Inst Co Ltd, Beijing, Peoples R China
[4] China Univ Petr East China, Oil & Gas CAE Technol Res Ctr, Qingdao 266580, Peoples R China
基金
中国国家自然科学基金;
关键词
Marine riser connectors; Multi-coupling models; Fatigue failure risk; Risk-based inspection; Risk early warning; ARTIFICIAL NEURAL-NETWORK; INDUCED VIBRATION; SIMULATION; VIV; PREDICTION; HISTORIES; TRANSFORM; CYLINDER; MODEL; PIPE;
D O I
10.1016/j.oceaneng.2022.110540
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
This paper discusses the effects of marine riser connectors (MRCs) on fatigue failure risk using multi-coupling models. When MRCs are subjected to vortex-induced fatigue, a risk early warning strategy is used for effective risk monitoring as a preventive measure for the operation of MRCs. To ensure safe marine oil and gas production and to improve fatigue failure prevention and control, research on offshore structural fatigue risk failure theory criteria and evaluation and the vibration fatigue characteristics of MRCs over time and frequency is characterized. By coupling data-driven technological means, including rain-flow counting (RFC), Hilbert-Huang transform (HHT), power spectral density (PSD), artificial neural network (ANN), risk-based inspection (RBI), and risk management measures (RMM) to assess the fatigue risk characteristics of in-service members in special offshore environments. The fluid-structure interaction characteristics of MRCs and a load spectrum are analysed by empirical mode decomposition (EMD) to determine the changes in the components of an intrinsic mode function (IMF) and investigate the degree of fatigue damage. The fatigue damage of MRCs is predicted using the PSD of the IMF and the RFC of the IMF-coupled ANN time series prediction model. The results show that using any IMF component or combined component data as input to the ANN and training set facilitates cross-validation of the analysis. When the input layer and a hidden layer of the ANN are optimized and properly trained, the predicted performance is suitable. Through early warnings and coordination, the spread of fatigue failure risk trends can be predicted, and warning information is issued accordingly.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] TOP TENSION RISER FATIGUE MONITORING SYSTEM
    Frazer, G. Ross
    Reagan, Daniel
    Ruf, Wolfgang
    Cheng, Jun
    OMAE2011: PROCEEDINGS OF THE ASME 30TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, VOL 4: PIPELINE AND RISER TECHNOLOGY, 2011, : 181 - +
  • [2] Fatigue resistant threaded and coupled connectors: The new standard for deep water riser applications
    Sches, Celine
    Hill, Joe W.
    Peter, Thomas
    Massaglia, Jacky
    Lepine, Etienne
    Proceedings of the 26th International Conference on Offshore Mechanics and Arctic Engineering, Vol 1, 2007, : 285 - 295
  • [3] The role of offshore monitoring in an effective deepwater riser integrity management program
    Goldsmith, Brittany
    Foyt, Elizabeth
    Hariharan, Madhu
    Proceedings of the 26th International Conference on Offshore Mechanics and Arctic Engineering, Vol 1, 2007, : 881 - 886
  • [4] Monitoring the structural integrity of a flexible riser during a full-scale fatigue test
    Clarke, T.
    Jacques, R.
    Bisognin, A.
    Camerini, C.
    Damasceno, S.
    Strohaecker, T.
    ENGINEERING STRUCTURES, 2011, 33 (04) : 1181 - 1186
  • [5] Research on Integrity management system based on corrosion risk online monitoring (CROM)
    Lai, HaiTao
    Tian, FaGuo
    Li, ZaiShun
    Yu, Shuzhen
    Yang, Bin
    Proceedings of the 2nd International Conference on Electronics, Network and Computer Engineering (ICENCE 2016), 2016, 67 : 565 - 568
  • [6] On the Value of Monitoring Information for the Structural Integrity and Risk Management
    Thoens, Sebastian
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2018, 33 (01) : 79 - 94
  • [7] Maintenance grouping optimization for the management of risk in offshore riser system
    Okoh, Peter
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2015, 98 : 33 - 39
  • [8] Fatigue Risk Management Systems: Issues of Air Crew Integrity and Liability
    Abeyratne, Ruwantissa
    AIR & SPACE LAW, 2012, 37 (02): : 119 - 139
  • [9] Continuum risk-based asset integrity management system for geothermal steam pipelines: Kamojang Unit 4, Indonesia
    Andi, Andi
    Zarrouk, Sadiq J.
    Kaya, Eylem
    Geothermics, 2021, 96
  • [10] Continuum risk-based asset integrity management system for geothermal steam pipelines: Kamojang Unit 4, Indonesia
    Andi, Andi
    Zarrouk, Sadiq J.
    Kaya, Eylem
    GEOTHERMICS, 2021, 96