The aim of hyperinflation in the ventilated intensive care unit patient is to increase oxygenation, reverse lung collapse and clear sputum. The efficacy and consistency of manual hyperventilation is well supported in the literature, but there is limited published evidence supporting hyperventilation utilising a ventilator. Despite this, a recent survey established that almost 40% of Australian tertiary intensive care units utilise ventilator hyperinflation. The aim of this non-inferiority cross-over study was to determine whether ventilator hyperinflation was as effective as manual hyperinflation in clearing sputum from patients receiving mechanical ventilation using a prescriptive ventilator hyperinflation protocol. A total of 46 patients received two randomly ordered physiotherapy treatments on the same day by the same physiotherapist. The efficacy of the hyperinflation modes was measured by sputum wet weight. Secondary measures included compliance, tidal volume, airway pressure and PaO2/FiO2 ratio. There was no difference in wet weight of sputum cleared using ventilator hyperinflation or manual hyperinflation (mean 3.2 g, P=0.989). Further, no difference in compliance (P=0.823), tidal volume (P=0.219), heart rate (P=0.579), respiratory rate (P=0.929) or mean arterial pressure (P=0.593) was detected. A statistically significant difference was seen in mean airway pressure (P=0.002) between techniques. The effect of techniques on the PaO2/FiO2 response ratio was dependent on time (interaction P=0.024). Physiotherapy using ventilator hyperinflation cleared a comparable amount of sputum and was as safe as manual hyperinflation. This research describes a ventilator hyperinflation protocol that will serve as a platform for continued discussion, research and development of its application in ventilated patients.
引用
收藏
页码:142 / 149
页数:8
相关论文
共 50 条
  • [1] Benefits and risks of manual hyperinflation in intubated and mechanically ventilated intensive care unit patients: a systematic review
    Frederique Paulus
    Jan M Binnekade
    Margreeth B Vroom
    Marcus J Schultz
    [J]. Critical Care, 16
  • [2] Benefits and risks of manual hyperinflation in intubated and mechanically ventilated intensive care unit patients: a systematic review
    Paulus, Frederique
    Binnekade, Jan M.
    Vroom, Margreeth B.
    Schultz, Marcus J.
    [J]. CRITICAL CARE, 2012, 16 (04)
  • [3] MANUAL HYPERINFLATION IN INTENSIVE CARE
    Bootsma, E.
    [J]. INTENSIVE CARE MEDICINE, 2010, 36 : S342 - S342
  • [4] Comparison of the effectiveness of manual and ventilator hyperinflation at different levels of positive end-expiratory pressure in artificially ventilated and intubated intensive care patients
    Savian, Camila
    Paratz, Jennifer
    Davies, Andrew
    [J]. HEART & LUNG, 2006, 35 (05): : 334 - 341
  • [5] Benefits and risks of ventilator hyperinflation in mechanically ventilated intensive care patients: A systematic review and meta-analysis
    Lockstone, Jane
    Love, Annabel
    Chian, Kimberly
    Garnham, Katherine
    Brumby, Susan
    Parry, Selina M.
    [J]. AUSTRALIAN CRITICAL CARE, 2023, 36 (06) : 1150 - 1158
  • [6] MANUAL HYPERINFLATION IS NOT BENEFICIAL IN VENTILATED PATIENTS.
    Speelberg, Ben
    van Hees, Arne
    [J]. CRITICAL CARE MEDICINE, 2008, 36 (12) : A138 - A138
  • [7] Manual and ventilator hyperinflation parameters used by intensive care physiotherapists in Sri Lanka: An online survey
    Liyanage, Indrajith
    Dassanayaka, D. A. R. K.
    Chellapillai, F. M. D.
    Liyanage, E.
    Rathnayake, S.
    Rikas, M.
    Mayooran, S.
    [J]. PLOS ONE, 2024, 19 (05):
  • [8] Head-down tilt and manual hyperinflation enhance sputum clearance in patients who are intubated and ventilated
    Berney, S
    Denehy, L
    Pretto, J
    [J]. AUSTRALIAN JOURNAL OF PHYSIOTHERAPY, 2004, 50 (01): : 9 - 14
  • [9] Effects of manual hyperinflation and suctioning on respiratory mechanics in mechanically ventilated patients with ventilator-associated pneumonia
    Choi, JSP
    Jones, AYM
    [J]. AUSTRALIAN JOURNAL OF PHYSIOTHERAPY, 2005, 51 (01): : 25 - 30
  • [10] PATIENT VENTILATOR ASYNCHRONY IN INVASIVELY VENTILATED CHILDREN IN PEDIATRIC INTENSIVE CARE UNIT
    Shaikh, F. A.
    Bhatia, P.
    Ramaswamy, K. N.
    Lingabathina, S.
    Yerra, A.
    Sachane, K.
    Chirla, D.
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2022, 23 (11)