Microstrip Line-Based Glucose Sensor for Noninvasive Continuous Monitoring Using the Main Field for Sensing and Multivariable Crosschecking

被引:59
|
作者
Huang, Shao Ying [1 ]
Omkar [1 ]
Yoshida, Yu [2 ]
Inda, Adan Jafet Garcia [2 ]
Xavier, Chia Xujie [1 ]
Mu, Wen Chuan [1 ]
Meng, Yu Song [3 ,4 ]
Yu, Wenwei [2 ]
机构
[1] Singapore Univ Technol & Design, Engn Prod Dev, Singapore 487372, Singapore
[2] Chiba Univ, Ctr Frontier Med Engn, Chiba 2638522, Japan
[3] Natl Metrol Ctr, Singapore 138632, Singapore
[4] Agcy Sci Technol & Res, Singapore 138632, Singapore
基金
新加坡国家研究基金会;
关键词
Glucose sensing; noninvasive; microstrip line; crosschecking; continuous glucose monitoring; CGM; microwave impedance spectroscopy; IN-VIVO;
D O I
10.1109/JSEN.2018.2877691
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Microstrip line (MLIN)-based glucose sensors have been used for noninvasive glucose monitoring. However, the current MLIN-based solutions do not provide enough sensitivity. The reason for this is that they rely on the fringing field of an MLIN that leads to a shallow penetration depth and thus low sensitivity. In this paper, we propose a sensitive MLIN-based glucose sensor using the main field. The idea is illustrated using the following three steps. Step 1 is sensing the glucose level by using the main field, which uses the material under test (MUT) as the substrate of an MLIN terminated with a load; Step 2 is identifying the contribution of different parameters and different components of parameters to sensitivity, which leads to Step 3, in which different parameters and/or different components of parameters are crosschecked for sensing. Two frequency bands, 100 to 500 MHz and 1.4 to 1.9 GHz, were investigated. In Step 1, the main field configuration was compared with its fringing field counterpart. It is shown that the proposed MLIN configuration presents an average sensitivity of 1.8 x 10(-3) dB/(mg/dL) in terms of the reflection coefficient that is more than 10 times higher than that of its counterpart. In Step 2, different components of the reflection coefficient and the input impedance of the proposed configuration were examined, and their diverse contributions to the sensitivity were shown, which allows crosschecking to improve sensing accuracy. This was successfully shown in Step 3, in which algorithms for crosschecking were proposed, and the sensing accuracy was examined. In terms of the optimal sensing frequency hand, 1.4 to 1.9 GHz shows higher sensitivity than 100 to 500 MHz, where the molecules may interact the most with the waves. This implies that the interaction between a wave and the sensing structure with the MUT contributes more to sensitivity than the direct interaction between the wave and the MUT. The radiofrequency safety of the proposed configuration was examined by checking the specific absorption rate of the MUT with the proposed structure. This paper offers a new avenue for the development of an MLIN-based noninvasive glucose sensor for continuous monitoring with high sensitivity in the near future. It can be used both as a single sensor and in a multiple-sensor glucose monitoring system.
引用
收藏
页码:535 / 547
页数:13
相关论文
共 20 条
  • [1] T-Shaped Patterned Microstrip Line for Noninvasive Continuous Glucose Sensing
    Omkar
    Yu, Wenwei
    Huang, Shao Ying
    [J]. IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS, 2018, 28 (10) : 942 - 944
  • [2] Sensitivity evaluation of miniature microstrip line-based sensors using multiple sensing parameters for non-invasive blood glucose monitoring
    Afshari, Nazanin
    Hashemi, Seyed Mohammad
    Geran, Fateme
    [J]. IET Microwaves, Antennas and Propagation, 2023, 17 (11): : 872 - 886
  • [3] Noninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses
    Ascaso, Francisco J.
    Huerva, Valentin
    [J]. OPTOMETRY AND VISION SCIENCE, 2016, 93 (04) : 426 - 434
  • [4] Noninvasive continuous monitoring of physiological glucose using a monosaccharide-sensing contact lens
    Badugu, R
    Lakowicz, JR
    Geddes, CD
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (03) : 610 - 618
  • [5] Noninvasive Continuous Glucose Monitoring on Aqueous Solutions Using Microwave Sensor with Machine Learning
    Bamatraf, Saeed M.
    Aldhaeebi, Maged A.
    Ramahi, Omar M.
    [J]. PROGRESS IN ELECTROMAGNETICS RESEARCH LETTERS, 2022, 102 : 127 - 134
  • [6] Noninvasive Continuous Glucose Monitoring on Aqueous Solutions Using Microwave Sensor with Machine Learning
    Bamatraf, Saeed M.
    Aldhaeebi, Maged A.
    Ramahi, Omar M.
    [J]. Progress in Electromagnetics Research Letters, 2022, 102 : 127 - 134
  • [7] In vivo continuous glucose monitoring using a chip based near infrared sensor
    Ben Mohammadi, L.
    Sigloch, S.
    Frese, I.
    Welzel, K.
    Goeddel, M.
    Klotzbuecher, T.
    [J]. BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE IV, 2014, 9129
  • [8] Noninvasive Continuous Glucose Monitoring Using a Multisensor-Based Glucometer and Time Series Analysis
    Zhanxiao Geng
    Fei Tang
    Yadong Ding
    Shuzhe Li
    Xiaohao Wang
    [J]. Scientific Reports, 7
  • [9] Noninvasive Continuous Glucose Monitoring Using a Multisensor-Based Glucometer and Time Series Analysis
    Geng, Zhanxiao
    Tang, Fei
    Ding, Yadong
    Li, Shuzhe
    Wang, Xiaohao
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [10] Continuous maternal hemodynamics monitoring at delivery using a novel, noninvasive, wireless, PPG-based sensor
    Atzmon, Yuval
    Ben-Ishai, Efrat
    Hallak, Mordechai
    Gabbay-Benziv, Rinat
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2020, 222 (01) : S184 - S185