Intra rater reliability of B mode ultrasound imaging of the abdominal muscles in healthy adolescents during the active straight leg raise test

被引:28
|
作者
Linek, Pawel
Saulicz, Edward
Wolny, Tomasz
Mysliwiec, Andrzej
机构
[1] Department of Kinesitherapy and Special Methods in Physiotherapy, The Jerzy Kukuczka Academy of Physical Education, Mikolowska 72B, Katowice
关键词
D O I
10.1016/j.pmrj.2014.07.007
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: To date, the reliability of ultrasound imaging (USI) measures of the abdominal muscles in children and adolescents during the active straight leg raise (ASLR) test has not been confirmed. Objective: To assess the intra-rater reliability of USI measures of the thickness and percentage thickness change of the external oblique (EO), internal oblique (IO), and transversus abdominis (TrA) on both sides of the body during the ASLR test in healthy adolescents. Design: Single-group repeated-measures intra-rater reliability study. Setting: School. Participants: Thirty-nine adolescents between the ages of 13 and 16 years. Methods: Three repeated USI measurements were recorded in the supine resting position and during the ASLR test at 2 sessions, 6 to 8 days apart. In the supine position, measurements were collected at the end of normal expiration. In the case of ASLR, measurements were collected when the person undergoing examination touched the transverse delimiter with the distal part of their lower leg, that is, to a 30 degrees flexion of the hip. Main Outcome Measurements: USI of abdominal muscle thickness. Results: By using the mean of 3 measures in the supine, resting position, intra-examiner reliability point estimates (intraclass correlation coefficient [ICC](3.3)) ranged from 0.95 to 0.97 for EO, IO, and TrA. During the ASLR test, the ICC result of thickness measurements of all muscles was also above 0.90. In terms of percentage change of muscle thickness, the highest ICC3.3 result obtained for the TrA was 0.81-0.85; for EO the result ranged from 0.72-0.89, and the result for the IO was between 0.65 and 0.79. Conclusion: USI measurements of the thickness of the EO, IO, and TrA muscles at rest and during the ASLR test in healthy adolescents between 13 and 16 years of age are reliable. Because of an increase in the precision of measurements, we recommend using the mean of 3 consecutive measurements of the EO, IO, and TrA muscles in adolescents to ensure a good reliability level. Based on 3 consecutive measurements, good reliability for the percentage change in the TrA thickness was achieved.
引用
收藏
页码:53 / 59
页数:1
相关论文
共 42 条
  • [1] Ultrasound Characteristics of the Deep Abdominal Muscles During the Active Straight Leg Raise Test
    Teyhen, Deydre S.
    Williamson, Jared N.
    Carlson, Nathan H.
    Suttles, Sean T.
    O'Laughlin, Shaun J.
    Whittaker, Jackie L.
    Goffar, Stephen L.
    Childs, John A.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (05): : 761 - 767
  • [2] Reliability of lumbar multifidus ultrasound assessment during the active straight leg raise test
    Plaza-Manzano, Gustavo
    Navarro-Santana, Marcos J.
    Antonio Valera-Calero, Juan
    Fabero-Garrido, Raul
    Fernandez-de-las-Penas, Cesar
    Lopez-de-Uralde-Villanueva, Ibai
    [J]. EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2022, 52 (05)
  • [3] ULTRASOUND IMAGING TRANSDUCER MOTION DURING CLINICAL MANEUVERS: RESPIRATION, ACTIVE STRAIGHT LEG RAISE TEST AND ABDOMINAL DRAWING IN
    Whittaker, Jackie L.
    Warner, Martin B.
    Stokes, Maria J.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (08): : 1288 - 1297
  • [4] The effect of pelvic compression on deep abdominal muscle thickness during the active straight leg raise test
    Brizzolara, Kelli
    Wang-Price, Sharon
    Roddey, Toni
    [J]. INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2015, 22 (02): : 60 - 66
  • [5] The Active Straight Leg Raise test in lumbopelvic pain during pregnancy
    Mens, Jan M. A.
    in 't Veld, Yvonne H. Huis
    Pool-Goudzwaard, Annelies
    [J]. MANUAL THERAPY, 2012, 17 (04) : 364 - 368
  • [6] The effect of pelvic compression on deep abdominal muscle thickness during the active straight leg raise test COMMENTARY
    Wilson, Iseult
    [J]. INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2015, 22 (02): : 67 - 67
  • [7] Inter-rater agreement, sensitivity, and specificity of the prone hip extension test and active straight leg raise test
    Bruno P.A.
    Millar D.P.
    Goertzen D.A.
    [J]. Chiropractic & Manual Therapies, 22 (1)
  • [8] Intra-rater Reliability of Ultrasound Imaging of Wrist Extensor Muscles in Patients With Tetraplegia
    Gorgey, Ashraf S.
    Timmons, Mark K.
    Michener, Lori A.
    Ericksen, Jeffery J.
    Gater, David R.
    [J]. PM&R, 2014, 6 (02) : 127 - 133
  • [9] Reliability of B-Mode Sonography of the Abdominal Muscles in Healthy Adolescents in Different Body Positions
    Linek, Pawel
    Saulicz, Edward
    Wolny, Tomasz
    Mysliwiec, Andrzej
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (06) : 1049 - 1056
  • [10] Repeatability of measuring sciatic nerve excursion during a modified passive straight leg raise test with ultrasound imaging
    Ridehalgh, Colette
    Moore, Ann
    Hough, Alan
    [J]. MANUAL THERAPY, 2012, 17 (06) : 572 - 576