Pulsed Doppler intraoperative flow assessment and midterm coronary graft patency

被引:21
|
作者
Louagie, YAG
Brockmann, CE
Jamart, J
Schroeder, E
Buche, M
Eucher, PM
Schoevaerdts, JC
机构
[1] Univ Louvain, Unit Cardiovasc & Thorac Surg, Univ Hosp Mont Godinne, B-5530 Yvoir, Belgium
[2] Univ Louvain, Unit Cardiol, Univ Hosp Mont Godinne, B-5530 Yvoir, Belgium
[3] Univ Louvain, Biostat Unit, Univ Hosp Mont Godinne, B-5530 Yvoir, Belgium
来源
ANNALS OF THORACIC SURGERY | 1998年 / 66卷 / 04期
关键词
D O I
10.1016/S0003-4975(98)00777-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. This study was designed to assess the value of hemodynamic measurements taken intraoperatively in predicting midterm patency of coronary bypass grafts. Methods. A pulsed Doppler flowmeter was routinely used during operation to determine the hemodynamic parameters of coronary bypass grafts. During a 7-year period, 85 patients underwent angiographic evaluation. As a result, a thorough hemodynamic assessment of 214 grafts (89 arterial and 125 venous) at initial operation was available for analysis. Results. The overall patency rate was 88.3%. The mean flow measured intraoperatively in 168 intact grafts was 60 +/- 3 mL/min (range, 9 to 230 mL/min), and the resistance was 1.8 +/- 0.1 peripheral resistance units (range, 0.3 to 9.0 peripheral resistance units). The mean flow was 36 +/- 5 mL/min (range, 2 to 107 mL/min), and the resistance was 5.9 +/- 2.0 peripheral resistance units (range, 0.6 to 46.0 peripheral resistance units) in 25 grafts found occluded at angiographic evaluation. Multivariate analysis identified three independent variables associated with a reduced patency rate: increased resistance as measured in the graft (p = 0.012), increasing interval of control angiography (p = 0.006), and preoperative cardiogenic shock (p = 0.040). Conclusions. The prognosis for midterm patency of aortocoronary bypass grafts depends on the intraoperative hemodynamic status. (Ann Thorac Surg 1998;66:1282-8) (C) 1998 by The Society of Thoracic Surgeons
引用
下载
收藏
页码:1282 / 1287
页数:6
相关论文
共 50 条
  • [1] NONINVASIVE ASSESSMENT OF AORTOCORONARY GRAFT PATENCY BY PULSED DOPPLER FLOWMETER
    THEROUX, P
    BOURASSA, MG
    DIEBOLD, B
    PERONNEAU, P
    BARBET, A
    GUERMONPREZ, JL
    CIRCULATION, 1977, 56 (04) : 25 - 25
  • [2] ASSESSMENT OF CORONARY-ARTERY BYPASS GRAFT FLOW BY INTRAOPERATIVE DOPPLER ULTRASOUND
    SIMPSON, IA
    SPYT, TJ
    WHEATLEY, DJ
    COBBE, SM
    BRITISH HEART JOURNAL, 1987, 57 (01): : 92 - 92
  • [3] Intraoperative analysis of coronary graft patency
    Lopez Almodovar, Luis F.
    CIRUGIA CARDIOVASCULAR, 2006, 13 (04): : 323 - 326
  • [4] PULSED DOPPLER ECHOCARDIOGRAPHY IN THE NON-INVASIVE ASSESSMENT OF AORTO-CORONARY BYPASS GRAFT PATENCY
    DIEBOLD, B
    GUERMONPREZ, JL
    WASSERMAN, JF
    BLANCHARD, D
    PERONNEAU, P
    THEROUX, P
    XHAARD, M
    MAURICE, P
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1980, 73 (11): : 1249 - 1257
  • [5] Intraoperattve coronary graft flow determination - Does it have a prognostic value for midterm graft patency?
    Cetin, S. M.
    Massoudy, P.
    Thielmann, M.
    Yildirim, C.
    Schmermund, A.
    Erbel, R.
    Jakob, H.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2006, 11 (07) : 267 - 272
  • [6] Is intraoperative measurement of coronary blood flow a good predictor of graft patency?
    D'Ancona, G
    Karamanoukian, HL
    Bergsland, J
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (05) : 1075 - 1076
  • [7] ASSESSMENT OF CORONARY-ARTERY BYPASS GRAFT FLOW BY INTRAOPERATIVE DOPPLER ULTRASOUND TECHNIQUE
    SIMPSON, IA
    SPYT, TJ
    WHEATLEY, DJ
    COBBE, SM
    CARDIOVASCULAR RESEARCH, 1988, 22 (07) : 484 - 488
  • [8] NONINVASIVE ASSESSMENT OF AORTOCORONARY BYPASS GRAFT PATENCY USING PULSED DOPPLER ECHOCARDIOGRAPHY
    DIEBOLD, B
    THEROUX, P
    BOURASSA, MG
    PERONNEAU, P
    GUERMONPREZ, JL
    AMERICAN JOURNAL OF CARDIOLOGY, 1979, 43 (01): : 10 - 16
  • [9] LIMITATION OF INTRAOPERATIVE GRAFT FLOW IN DETERMINING LATE GRAFT PATENCY
    WEINBERG, D
    GOLDMAN, S
    SALOMON, N
    OVITT, T
    COPELAND, J
    CLINICAL RESEARCH, 1980, 28 (01): : A15 - A15
  • [10] INTRAOPERATIVE ASSESSMENT OF FLOW CHARACTERISTICS IN CORONARY STENOSIS BY 20MHZ MULTIGATED PULSED DOPPLER VELOCIMETRY
    WADA, Y
    OGASAWARA, Y
    GOTO, M
    TSUJIOKA, K
    MATSUOKA, S
    KANAZAWA, S
    FUJIWARA, T
    KAJIYA, F
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1987, 51 (08): : 876 - 877