Probe distance error analysis for phased array calibration based on BTM

被引:0
|
作者
Lu, Yangyi [1 ]
Shi, Suyang [1 ]
Cui, Mantang [1 ]
Zhou, Lei [1 ]
机构
[1] Nanjing Marine Radar Inst, Dept Antenna & Microwave Syst, Nanjing, Peoples R China
关键词
backward transformation method; error analysis; phased array calibration; probe distance; Taylor expansion;
D O I
10.1002/mop.33150
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Based on backward transformation method (BTM), the probe distance error analysis in z-axis for phased array calibration is described. When BTM is employed in phased array calibration to obtain the electric field over the radiation aperture of antenna, the Taylor expansion of probe distance error is used for analyzing the accuracy of reconstructed aperture field. It is found that probe distance error less than 1/35 of a wavelength is recommended. To verify this conclusion, the measured results demonstrate the validation of this analysis, which is helpful in the near-field calibration for phased array.
引用
收藏
页码:496 / 499
页数:4
相关论文
共 50 条
  • [1] Fixed Probe Based Digital Phased Array Calibration Using Virtual Probe Location
    Islam, Shajid
    Fulton, Caleb
    [J]. 2020 IEEE INTERNATIONAL RADAR CONFERENCE (RADAR), 2020, : 792 - 797
  • [2] Phased Array Antenna Calibration with Probe Positioning Errors
    Korotetskiy, Yegor V.
    Shitikov, Alexander M.
    Denisenko, Vladimir V.
    [J]. IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2016, 58 (03) : 65 - +
  • [3] Analysis of Amplitude-phase Error of Phased Array Calibration in Mid-field
    Gu, Qiang
    Dai, Chengran
    Zhang, Chuanfang
    Yuan, Haopeng
    [J]. PROCEEDINGS OF 2014 3RD ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP 2014), 2014, : 280 - 283
  • [4] Calibration Quality Analysis of Phased Array Antennas
    Kilic, Ozgehan
    Yalim, Alper
    Cetintepe, Cagri
    Demir, Simsek
    [J]. 2012 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2012,
  • [5] Phased array calibration
    Sorace, R
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2001, 49 (04) : 517 - 525
  • [6] Phased array calibration
    Sorace, R
    [J]. 2000 IEEE INTERNATIONAL CONFERENCE ON PHASED ARRAY SYSTEMS AND TECHNOLOGY, PROCEEDINGS, 2000, : 533 - 536
  • [7] Calibration method of phased array radar based on FFT
    Lu, Jiaguo
    Wu, Manqing
    Chen, Siqiao
    Fang, Zhengxin
    [J]. Dianbo Kexue Xuebao/Chinese Journal of Radio Science, 2000, 15 (02): : 221 - 224
  • [8] Calibration Array Based Near-Field Multi-Probe OTA Calibration for 5G Phased Arrays
    Ma, Menglu
    Zhao, Deshuang
    Yang, Zhouming
    Liang, Feng
    Cao, Weiping
    Wang, Bingzhong
    [J]. Dianzi Keji Daxue Xuebao/Journal of the University of Electronic Science and Technology of China, 2021, 50 (06): : 883 - 889
  • [9] A Study on the Channel Error Tolerance and LUT Calibration for Active Phased Array Antenna
    Jang, Sunghoon
    Kim, Donghwan
    Kim, Seonjoo
    [J]. 2015 16TH INTERNATIONAL RADAR SYMPOSIUM (IRS), 2015, : 1094 - 1099
  • [10] Parameter Calibration Model and Redundancy Analysis of Robot Based on Distance Error
    Shen, Jingjin
    Guo, Jiazhen
    Masoud, Kalantari
    [J]. Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2018, 49 (11): : 372 - 378