Acetabular Component and Liner Selection for the Prevention of Dislocation After Primary Total Hip Arthroplasty

被引:0
|
作者
Kunze, Kyle N. [1 ]
Premkumar, Ajay [1 ]
Bovonratwet, Patawut [1 ]
Sculco, Peter K. [1 ]
机构
[1] Hosp Special Surg, Dept Orthoped Surg, New York, NY 10021 USA
关键词
DUAL-MOBILITY; RISK-FACTORS; WEAR PERFORMANCE; UNITED-STATES; SURGERY; RATES; CUPS; EPIDEMIOLOGY; POSITION; ANATOMY;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
& drangbrac;Primary total hip arthroplasty (THA) is a reproducible and efficacious procedure for patients with end-stage osteoarthritis; however, dislocation remains the most common cause of revision arthroplasty.& drangbrac;Technological advancements in acetabular component design and liner options, in conjunction with a more comprehensive understanding of the spinopelvic factors that influence dislocation, will likely reduce the risk of dislocation and revision over time.& drangbrac;The contemporary liner and shell options for primary THA, in order of increasing constraint and stability, include (1) neutral, (2) lateralized, (3) face-changing (oblique), (4) lipped (high-wall) with or without lateralization, (5) modular and anatomic dual-mobility, and (6) constrained options.& drangbrac;Different liner designs can alter functional anteversion, inclination, and jump distance, and can be used to minimize a single predictable dislocation vector (lipped [high-wall] liners) or multiple vectors of instability risk when the dislocation direction is unpredictable (dual-mobility liners).& drangbrac;Liner selection should be based on the patient-specific risk of dislocation, including static anatomic (e.g., large anterior inferior iliac spine or greater trochanter morphology), dynamic anatomic (e.g., limited sitting-standing change in the sacral slope), and demographic or medical (e.g., neurocognitive disorders and obesity) risk factors.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] The effect of acetabular and femoral component version on dislocation in primary total hip arthroplasty
    Takaaki Fujishiro
    Takafumi Hiranaka
    Shingo Hashimoto
    Shinya Hayashi
    Masahiro Kurosaka
    Taiki Kanno
    Takeshi Masuda
    International Orthopaedics, 2016, 40 : 697 - 702
  • [2] The effect of acetabular and femoral component version on dislocation in primary total hip arthroplasty
    Fujishiro, Takaaki
    Hiranaka, Takafumi
    Hashimoto, Shingo
    Hayashi, Shinya
    Kurosaka, Masahiro
    Kanno, Taiki
    Masuda, Takeshi
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (04) : 697 - 702
  • [3] Reducing the risk of dislocation after total hip arthroplasty -: The effect of orientation of the acetabular component
    Biedermann, R
    Tonin, A
    Krismer, M
    Rachbauer, F
    Eibl, G
    Stöckl, B
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (06): : 762 - 769
  • [4] Short-term results with a constrained acetabular liner in patients at high risk of dislocation after primary total hip arthroplasty
    Gill, Kathryn
    Whitehouse, Sarah L.
    Hubble, Matthew J. W.
    Wilson, Matthew J.
    HIP INTERNATIONAL, 2016, 26 (06) : 580 - 584
  • [5] Use of a Constrained Acetabular Liner to Prevent and Treat Recurrent Dislocation after Total Hip Replacement Arthroplasty
    Song, Joo Hyoun
    Kwon, Won Hwan
    Oh, Seung-Bae
    Moon, Kyoung Ho
    ORTHOPAEDIC SURGERY, 2020, 12 (06) : 2004 - 2012
  • [6] Prevention of Dislocation After Total Hip Arthroplasty
    Rowan, Fiachra E.
    Benjamin, Biju
    Pietrak, Jurek R.
    Haddad, Fares S.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (05): : 1316 - 1324
  • [7] Dislocation after polyethylene liner exchange in total hip arthroplasty
    Boucher, HR
    Lynch, C
    Young, AM
    Engh, CA
    Engh, C
    JOURNAL OF ARTHROPLASTY, 2003, 18 (05): : 654 - 657
  • [8] Effect of acetabular component anteversion on dislocation mechanisms in total hip arthroplasty
    Higa, Masaru
    Tanino, Hiromasa
    Abo, Masayoshi
    Kakunai, Satoshi
    Banks, Scott A.
    JOURNAL OF BIOMECHANICS, 2011, 44 (09) : 1810 - 1813
  • [9] Catastrophic Wear of an Acetabular Component Misdiagnosed as Total Hip Arthroplasty Dislocation
    Papaioannou, Ioannis
    Pantazidou, Georgia
    Chatziperi, Stamatia
    Baikousis, Andreas
    Korovessis, Panagiotis
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (11)
  • [10] Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner
    Livingston, BJ
    Chmell, MJ
    Spector, M
    Poss, R
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (10): : 1529 - 1538