Initial validation of a diaphragm tracking system for multiple breath-hold volumetric modulated arc therapy of abdominal tumors: A phantom study

被引:1
|
作者
Nozawa, Yuki [1 ]
Ohta, Takeshi [1 ]
Katano, Atsuto [1 ]
Nawa, Kanabu [1 ]
Ohira, Shingo [2 ]
Yamashita, Hideomi [1 ]
Nakagawa, Keiichi [2 ]
机构
[1] Univ Tokyo Hosp, Dept Radiol, Bunkyo Ku,7-3-1 Hongo, Tokyo 1138655, Japan
[2] Univ Tokyo, Dept Comprehens Radiat Oncol, Bunkyo Ku, Tokyo, Japan
关键词
breath-hold; diaphragm; projection streaming;
D O I
10.1002/mp.17008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe breath-hold radiotherapy has been increasingly used to mitigate interfractional and intrafractional breathing impact on treatment planning and beam delivery. Previous techniques include body surface measurements or radiopaque metal markers, each having known disadvantages.PurposeWe recently proposed a new markerless technique without the disadvantages, where diaphragm was registered between DRR and fluoroscopic x-ray projection images every 180 ms during VMAT delivery. An initial validation of the proposed diaphragm tracking system (DiaTrak) was performed using a chest phantom to evaluate its characteristics.MethodsDiaphragm registration was performed between DRR and projection streaming kV x-ray images of a chest phantom during VMAT delivery. Streaming data including the projection images and the beam angles were transferred from a linac system to an external PC, where the diaphragm registration accuracy and beam-off latency were measured based on image cross correlation between the DRR and the projection images every 180 ms.ResultsIt was shown that the average of the beam-off latency was 249.5 ms and the average of the diaphragm registration error was 0.84 mmConclusionsInitial validation of the proposed DiaTrak system for multiple breath-hold VMAT of abdominal tumors has been successfully completed with a chest phantom. The resulting beam-off latency and the diaphragm registration error were regarded clinically acceptable.
引用
收藏
页码:2378 / 2385
页数:8
相关论文
共 50 条
  • [1] Diaphragm Tracking System That Superimposes Planned Diaphragm Contours on Kilovolt Cine Images During Multiple Breath-Hold Volumetric Modulated Arc Therapy for Abdominal Tumors
    Nozawa, Yuki
    Ohta, Takeshi
    Katano, Atsuto
    Yamashita, Hideomi
    Nakagawa, Keiichi
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [2] Multiple Breath-hold Volumetric Modulated Arc Therapy Under Fluoroscopic Image Guidance with an Implanted Fiducial Marker: An Advanced Technique
    Takanaka, Tsuyoshi
    Taima, Yoko
    Horichi, Yasushi
    Kawamori, Yasuhiro
    Nobata, Koji
    Kitagawa, Kiyohide
    Norishima, Azusa
    Koshikawa, Kento
    Mito, Tatsuya
    Yoshida, Satoshi
    Kawanaka, Tetsuya
    Matsutani, Katsuaki
    Kawahara, Masahiro
    [J]. CUREUS, 2018, 10 (04):
  • [3] A method for beam?s eye view breath-hold monitoring during breast volumetric modulated arc therapy
    Carr, Michael A.
    Gargett, Maegan
    Stanton, Cameron
    Zwan, Benjamin
    Byrne, Hilary L.
    Booth, Jeremy T.
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 25
  • [4] Voluntary deep inspiration breath-hold with volumetric modulated arc therapy in pediatric patients with mediastinal Hodgkin lymphoma
    Shaheen, Haitham
    Zaghloul, Mohamed S.
    Ammar, Hany
    Aly, Bakr
    Hassanin, Ehab
    Abd-el Mohsen, Soheir
    Ahmed, Soha
    [J]. FUTURE ONCOLOGY, 2023, 19 (02) : 137 - 145
  • [5] Dosimetric Analysis of Multiple Breath-Hold Segmented Volumetric Modulated Arc Radiation Therapy Plans with and without Fiducial Markers for Pancreatic Cancer
    Kawakami, W., Jr.
    Takamatsu, S.
    Takanaka, T.
    Nakaichi, T.
    Takemura, A.
    Urabe, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E555 - E555
  • [6] 3D Lung Tumor Position Verification During Breath-Hold Stereotactic Volumetric Modulated Arc Therapy
    Hazelaar, C.
    Dahele, M.
    Mostafavi, H.
    van der Weide, L.
    Keek, S.
    Slotman, B.
    Verbakel, W.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3224 - 3224
  • [7] Epid-based in vivo dose verification for lung stereotactic treatments delivered with multiple breath-hold segmented volumetric modulated arc therapy
    Cilla, Savino
    Ianiro, Anna
    Craus, Mauriz O.
    Viola, Pietro
    Deodato, Francesco
    Macchia, Gabriella
    Buwenge, Milly
    Morganti, Alessio G.
    Valentini, Vincenzo
    Piermattei, Angelo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (03): : 37 - 44
  • [8] Volumetric modulated arc therapy and breath-hold in image-guided locoregional left-sided breast irradiation
    Osman, Sarah O. S.
    Hol, Sandra
    Poortmans, Philip M.
    Essers, Marion
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 112 (01) : 17 - 22
  • [9] Feasibility Study of Deep Inspiration Breath-Hold Based Volumetric Modulated Arc Therapy for Locally Advanced Left Sided Breast Cancer Patients
    Swamy, Shanmugam Thirumalai
    Radha, Chandrasekaran Anu
    Kathirvel, Murugesan
    Arun, Gandhi
    Subramanian, Shanmuga
    [J]. ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (20) : 9033 - 9038
  • [10] Lung Cancer: Doses to Mediastinal Structures Can Be Reduced with Volumetric Modulated Arc Therapy and Deep Inspiration Breath-Hold Radiotherapy
    Persson, Gitte F.
    Rydhog, Jonas S.
    Aznar, Marianne C.
    Maraldo, Maja V.
    Nygard, Lotte
    Costa, Junia
    Berthelsen, Anne K.
    Specht, Lena
    Josipovic, Mirjana
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S687 - S688