Accuracy of CAD/CAM and 3D printing in the treatment of feline femoral neck fracture

被引:0
|
作者
Trebacz, Piotr [1 ,3 ]
Barteczko, Anna [2 ]
Kurkowska, Aleksandra [2 ]
Pawlik, Mateusz [2 ]
Galanty, Marek [1 ]
机构
[1] SGGW Warszawie, Inst Med Weterynaryjnej, Zaklad Chirurgii & Anestezjol Malych Zwierzat, Ul Nowoursynowska 159 C, PL-02776 Warsaw, Poland
[2] CABIOMEDE Sp Zoo, Ul Karola Olszewskiego 6, PL-25663 Kielce, Poland
[3] Ul Nowoursynowska 159 C, PL- 02776 Warsaw, Poland
关键词
cat; femur; drill guide; 3D printing; GUIDE;
D O I
10.21521/mw.6772
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The aim of this study was to investigate whether a CT scan provides accurate bone surface information for feline bone model development. The second part of study consisted of 3D printing of feline femoral bone models with and without femoral neck fractures (31-B1 and 31-B2 in AO VET classification), as well as the development and 3D printing of drill guides for treatment of femoral neck fractures. The study was carried out on eight models of femoral bones and four drill guides. Initially, trial models of the right and left femurs without neck fractures and trial drill guides were used. Radiographs showed that the use of the prototype guides made it possible to drill holes in the axes of the necks of the femurs. Then, after assessing the correct operation of the guides and improving their adhesion to the bone surface by smoothing the inner surfaces of the guide bases, final bone models without femoral neck fracture, models with fractures 31-B1 and 31-B2, and final drill guides were printed. All models featured a 2.7 x 30 mm positional cortical screw. Radiographs of the models, made after inserting screws, showed that the implants were placed as intended. Also in the longitudinal sections of the heads and necks of the femoral bones of the models without fractures, the implants were positioned in the intended places.
引用
收藏
页码:279 / 285
页数:7
相关论文
共 50 条
  • [1] Accuracy of CAD/CAM-fabricated bite splints: milling vs 3D printing
    Marcel, Reymus
    Reinhard, Hickel
    Andreas, Kessler
    [J]. CLINICAL ORAL INVESTIGATIONS, 2020, 24 (12) : 4607 - 4615
  • [2] Accuracy of CAD/CAM-fabricated bite splints: milling vs 3D printing
    Reymus Marcel
    Hickel Reinhard
    Keßler Andreas
    [J]. Clinical Oral Investigations, 2020, 24 : 4607 - 4615
  • [3] Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method
    Jeong, Yoo-Geum
    Lee, Wan-Sun
    Lee, Kyu-Bok
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (03): : 245 - 251
  • [4] Comparing the accuracy of crown fitting between milling and 3D printing techniques using CAD/CAM technologies
    Alhamoudi, Fahad Hussain
    [J]. TECHNOLOGY AND HEALTH CARE, 2024, 32 (04) : 2755 - 2768
  • [5] Maxillary Total Elongation Surgery using 3D Virtual Surgery, CAD/CAM and 3D Printing Technology: Surgical Convenience and Accuracy
    Ha, Sung-Ho
    Maeng, Ji Youn
    Baek, Seung-Hak
    Choi, Jin-Young
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2022, 33 (07) : 2172 - 2177
  • [6] CAD printing in 3D
    不详
    [J]. COMPUTER GRAPHICS WORLD, 2001, 24 (03) : 12 - 12
  • [7] CAD/CAM system and experimental study of biological 3D printing composite process
    [J]. Liu, Yuanyuan, 1600, Chinese Mechanical Engineering Society (50):
  • [8] CAD CAM System for Manufacturing Innovative Hybrid Design Using 3D Printing
    Mikolajczyk, Tadeusz
    Malinowski, Tomasz
    Moldovan, Liviu
    Hu Fuwen
    Paczkowski, Tomasz
    Ciobanu, Ileana
    [J]. 12TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING (INTER-ENG 2018), 2019, 32 : 22 - 28
  • [9] 3D CAD/CAM and PDM software
    不详
    [J]. AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 2000, 72 (04): : 393 - 394
  • [10] CAD/CAM for scalable nanomanufacturing: A network-based system for hybrid 3D printing
    Hae-Sung Yoon
    Hyun-Taek Lee
    Ki-Hwan Jang
    Chung-Soo Kim
    Hyunseo Park
    Dae-Wook Kim
    Kunwoo Lee
    Sangkee Min
    Sung-Hoon Ahn
    [J]. Microsystems & Nanoengineering, 3