摘要
Partial discharge (PD) diagnostics test is a reliable solution for estimating insulation health conditions in power system components. During laboratory PD diagnostics, the effect of harmonic components in the voltage waveform generated by variable frequency drives (VFD) fed electric motors (EMs) is often overlooked. As VFD-fed EMs operate at low speeds, the harmonic concentration in the voltage increases. It has been found that PD activity in VFD-fed EM is significantly affected by the addition of harmonic components in the voltage, thus making it necessary to consider their impact when performing true PD diagnostics. This paper investigates the influence of voltage harmonic distortion produced in VFD-fed EM on PD severity and the subsequent insulation degradation. Eight VFD-fed EM are used to study the PD behaviour under different levels of harmonic pollution. The PD characteristics, such as inception voltage, pulse repetition rate, accumulated apparent charge, average discharge current, discharge power, and quadratic rate, are determined. Using probability distribution functions, PD activity and severity at various voltage harmonic levels are estimated. The proposed technique can be used to plan the maintenance activities that ensure the reliability for industrial applications dealing with the voltage harmonic distortion. During laboratory partial discharge (PD) diagnostics, the effect of harmonic components in the voltage waveform generated by variable frequency drives (VFD) fed electric motors (EMs) is often overlooked. The proposed technique includes the impact of voltage harmonics on PD activity and can be used to plan the maintenance activities that ensure the reliability for industrial applications. image
引用
收藏
页码:506 / 516
页数:11
相关论文
共 45 条
  • [1] Influence of Voltage Harmonics on Partial Discharge Diagnostics in Electric Motors Fed by Variable-Frequency Drives
    Hassan, Waqar
    Mahmood, Farhan
    Andreotti, Amedeo
    Pagano, Mario
    Ahmad, Farooq
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (10) : 10605 - 10614
  • [2] Quantifying the Probability of Partial Discharge in VFD Fed Electric Motors under Voltage Harmonics Concentration
    Hassan, Waqar
    Hussain, Ghulam Amjad
    Mahmood, Farhan
    Akmal, Muhammad
    [J]. 2022 20TH INTERNATIONAL CONFERENCE ON HARMONICS & QUALITY OF POWER (ICHQP 2022), 2022,
  • [3] Asynchronous electric motors for variable-frequency electric drives of drilling rigs
    Abramov B.I.
    Makarov L.N.
    Breslav B.M.
    Ponomarev V.M.
    Parfenov B.M.
    [J]. Russian Electrical Engineering, 2009, 80 (1) : 10 - 14
  • [4] Variable Frequency Drives with Two-Speed Asynchronous Electric Motors
    Karandaev, A. S.
    Khramshina, E. A.
    Kornilov, G. P.
    Grigorjan, V. V.
    Karandaeva, O., I
    [J]. PROCEEDINGS OF THE 2016 IEEE NORTH WEST RUSSIA SECTION YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING CONFERENCE (ELCONRUSNW), 2016, : 581 - 586
  • [5] Partial discharge diagnostics on inverter-fed drives of electric vehicles
    Zajadatz, Maurizio
    Woehr, Erik
    Suriyah, Michael
    Leibfried, Thomas
    [J]. ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2023, 140 (7-8): : 626 - 633
  • [6] Noise characteristics of electric motors of variable-frequency geared electric drives for elevators
    Afonin V.I.
    Zapadnya M.F.
    [J]. Russian Electrical Engineering, 2010, 81 (12) : 644 - 648
  • [7] A DFFT and Coherence Analysis-Based Fault Diagnosis Approach for Induction Motors Fed by Variable Frequency Drives
    Shabbir, Md Nasmus Sakib Khan
    Liang, Xiaodong
    [J]. 2020 IEEE CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2020,
  • [8] OPTIMAL EFFICIENCY ANALYSIS OF INDUCTION-MOTORS FED BY VARIABLE VOLTAGE AND VARIABLE FREQUENCY SOURCE
    CHEN, S
    YEH, SN
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 1992, 7 (03) : 537 - 543
  • [9] EXPERIENCE WITH ON-LINE PARTIAL DISCHARGE MEASUREMENT IN HIGH VOLTAGE INVERTER FED MOTORS
    Stone, G. C.
    Sedding, H. G.
    Chan, C.
    [J]. 2016 Petroleum and Chemical Industry Technical Conference (PCIC), 2016,
  • [10] Simulated Energy-Efficient Voltage Frequency Ratios of Variable-Frequency Drives on Induction Motors
    Wang, Gang
    Kiamehr, Koosha
    [J]. ASHRAE TRANSACTIONS, VOL 122, PT 2, 2016, 122 : 149 - 159