Is the rod necessary? Biomechanical comparison of static knee spacers during axial loading

被引:0
|
作者
Egenolf, Philipp [1 ,2 ]
Wasseq, Dorothee [1 ,2 ]
Scheyerer, Max Joseph [1 ,2 ]
Prescher, Andreas [3 ]
Wegmann, Kilian [1 ,2 ,4 ]
Mueller, Lars Peter [1 ,2 ]
Eysel, Peer [1 ,2 ]
Otto-Lambertz, Christina [1 ,2 ]
机构
[1] Univ Cologne, Fac Med, Joseph Stelzmann Str 24, D-50931 Cologne, Germany
[2] Univ Hosp Cologne, Dept Orthopaed & Trauma Surg, Joseph Stelzmann Str 24, D-50931 Cologne, Germany
[3] Univ Hosp Aachen, Inst Mol & Cellular Anat, Pauwelsstr 40, D-52074 Aachen, Germany
[4] OCM Orthopad Chirurg Munchen Clin, Steinerstr 6, D-81369 Munich, Germany
关键词
Revision knee arthroplasty; Spacer; Loading capacity; Biomechanics; 2-STAGE REVISION; SEVERE BONE;
D O I
10.1016/j.clinbiomech.2022.105867
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Knee Spacers are required in two-stage revision surgery of periprosthetic joint infection of the knee. Extended bone and ligamentous defects are often temporarily arthrodised via a static spacer. Regarding their weight-bearing potential and construction, there is no current consent. Our aim was to evaluate three individual static spacer variants with regard to their axial loading capacity. Methods: The static spacer variants were tested in a cadaver model. One after the other, a spacer with metal -reinforced rods, a spacer without metal reinforcement and a rod-less spacer were implanted and tested up to an axial loading of 1000 Newton. Target parameters were plastic deformation, stiffness and spacer movement at both the femoral and tibial surface. Loading was applied up to 1000 Newton. Radiological controls of the bone substance were performed. Findings: The spacer variants did not differ regarding deformation, stiffness or spacer movement. However, deformation increased significantly with the axial load in all spacer variants. Radiographs showed no fracture or spacer-dislocation resulting from testing. Interpretation: While the spacer reinforcement or the sheer presence of a rod did not influence the axial loading capacity in this in vitro study, weightbearing should be discouraged to limit further bone erosion.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] AXIAL LOADING ON A STATIC KNEE-ANKLE-FOOT ORTHOSIS
    ANDERSON, EG
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1977, 1 (02) : 100 - 102
  • [2] Loading capacity of dynamic knee spacers: a comparison between hand-moulded and COPAL spacers
    Sook-Yee Chong
    Lu Shen
    Sandra Frantz
    [J]. BMC Musculoskeletal Disorders, 20
  • [3] Loading capacity of dynamic knee spacers: a comparison between hand-moulded and COPAL spacers
    Chong, Sook-Yee
    Shen, Lu
    Frantz, Sandra
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [4] Comparison of outcomes between static spacers versus articulating spacers in the setting of revision periprosthetic knee infections: a systematic review
    Limtong, Justin
    Pannu, Tejbir S.
    Villa, Jesus M.
    Riesgo, Aldo M.
    Higuera, Carlos A.
    [J]. ANNALS OF JOINT, 2021, 6 (01):
  • [5] Comparison of articulating and static spacers regarding infection with resistant organisms in total knee arthroplasty
    Chiang, En-Rung
    Su, Yu-Ping
    Chen, Tain-Hsiung
    Chiu, Fang-Yao
    Chen, Wei-Ming
    [J]. ACTA ORTHOPAEDICA, 2011, 82 (04) : 460 - 464
  • [6] Comparison of static and dynamic knee kinematics during squatting
    Mu, S.
    Moro-oka, T.
    Johal, P.
    Hamai, S.
    Freeman, M. A. R.
    Banks, S. A.
    [J]. CLINICAL BIOMECHANICS, 2011, 26 (01) : 106 - 108
  • [7] Comparison of static and mobile antibiotic-impregnated cement spacers for the treatment of infected total knee arthroplasty
    Sang-Jin Park
    Eun-Kyoo Song
    Jong-Keun Seon
    Taek-Rim Yoon
    Gi-Heon Park
    [J]. International Orthopaedics, 2010, 34 : 1181 - 1186
  • [8] Comparison of static and mobile antibiotic-impregnated cement spacers for the treatment of infected total knee arthroplasty
    Park, Sang-Jin
    Song, Eun-Kyoo
    Seon, Jong-Keun
    Yoon, Tack-Rim
    Park, Gi-Heon
    [J]. INTERNATIONAL ORTHOPAEDICS, 2010, 34 (08) : 1181 - 1186
  • [9] Biomechanical evaluation of knee endpoint during anterior tibial loading: Implication for physical exams
    Rahnemai-Azar, Ata A.
    Arilla, Fabio V.
    Bell, Kevin M.
    Fu, Freddie H.
    Musahl, Volker
    Debski, Richard E.
    [J]. KNEE, 2017, 24 (02): : 258 - 263
  • [10] The Modified Static Spacers Using Antibiotic-Impregnated Cement Rod in Two-Stage Revision for Infected Total Knee Arthroplasty
    Yoo, Juhyung
    Lee, Seungyup
    Han, Changdong
    Chang, Jihoon
    [J]. CLINICS IN ORTHOPEDIC SURGERY, 2011, 3 (03) : 245 - 248