Conventional office blood pressure measurements and unattended automated office blood pressure compared with home self-measurement and 24-h ambulatory blood pressure monitoring

被引:2
|
作者
Fonseca-Reyes, Salvador [1 ,2 ,7 ]
Fonseca-Cortes, Karla [2 ]
Coca, Antonio [3 ]
Romero-Velarde, Enrique [4 ,5 ,6 ]
Perez-Molina, Jesus [5 ,6 ]
机构
[1] Nuevo Hosp Civil Guadalajara, Hypertens Clin, Dept Internal Med, Guadalajara, Mexico
[2] Univ Guadalajara, Inst Invest Cardiovasc, Guadalajara, Mexico
[3] Univ Barcelona, Hosp Clin, Dept Internal Med, Hypertens & Vasc Risk Unit, Barcelona, Spain
[4] Univ Guadalajara, Ctr Univ Ciencias Salud, Dept Clin Reprod Humana Crecimiento & Desarrollo I, Inst Nutr Humana, Guadalajara, Mexico
[5] Nuevo Hosp Civil Guadalajara, Div Pediat, Guadalajara, Mexico
[6] Univ Guadalajara, Ctr Univ Ciencias Salud, Dept Clin Reprod Humana Crecimiento & Desarrollo I, Guadalajara, Mexico
[7] Nuevo Hosp Civil Guadalajara, Hypertens Clin, Dept Internal Med, Salvador Quevedo & Zubieta 750 Col, Guadalajara 44340, Jalisco, Mexico
关键词
ambulatory blood pressure monitoring; automated blood pressure; conventional measurement; home-self blood pressure; out-to-office blood pressure; SOCIETY-OF-HYPERTENSION; EUROPEAN-SOCIETY; VALIDATION; DEVICE; TIME;
D O I
10.1097/MBP.0000000000000629
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To assess whether automated office blood pressure (BP) (AOBP) measurement is a better method for measuring BP in the office than conventional techniques and an alternative to out-of-office BP measurements: home-self BP (HSBP) or ambulatory BP monitoring (ABPM). Methods We conducted a cross-sectional study of 74 patients and compared AOBP with the conventional technique using a mercury sphygmomanometer and with both out-to-office BP measurements: HSBP of 7 days (three measurements in the morning, afternoon, and night) and daytime ABPM. In addition, we compared BP values obtained using HSBP and ABPM to determine their level of agreement. We used ANOVA to compare means, Bland-Altman, and intraclass correlation coefficients (ICC) for concordance. Results BP values obtained by the two office methods were similar: conventional 147.2/85.0 mmHg and AOBP 146.0/85.5 mmHg (P > 0.05) with good agreement (ICC 0.85). The mean SBP differences between AOBP and HSBP (P < 0.001) and between AOBP and ABPM (P < 0.001) were 8.6/13.0 mmHg with limits of agreement of -21.2 to 38.5 and -18.4 to 44.3 mmHg, respectively. The average SBP values obtained by HSBP were 4.3 mmHg higher than those obtained by ABPM (P < 0.01). Conclusion Our study showed good agreement and concordance between the two office methods as well between the two out-to-office methods, although there was a significant difference in the mean SBP between the HSBP and ABPM. Moreover, AOBP was not comparable to either HSBP or ABPM; therefore, the estimation of out-to-office BP using AOBP is not supported.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [1] Comparison of Office Blood Pressure, Automated Unattended Office Blood Pressure, Home Blood Pressure, and 24-Hour Ambulatory Blood Pressure Measurements
    Kim, Byung Jin
    Lee, Sung Ho
    Lee, Mi Yeon
    Lee, Seung Jae
    Choi, Hyo In
    [J]. JOURNAL OF KOREAN MEDICAL SCIENCE, 2023, 38 (48)
  • [2] Significance of blood pressure self-measurement as compared with office blood pressure measurement and ambulatory 24-hour blood pressure measurement in pharmacological studies
    Mengden, T
    Uen, S
    Baulmann, J
    Vetter, H
    [J]. BLOOD PRESSURE MONITORING, 2003, 8 (04) : 169 - 172
  • [3] Self-measurement of blood pressure in the office and at home
    Myers, MG
    Parati, G
    [J]. JOURNAL OF HYPERTENSION, 2003, 21 (12) : 2223 - 2225
  • [4] HOME SELF MEASUREMENT MONITORING OF BLOOD PRESSURE: RELATION TO OFFICE AND AMBULATORY BLOOD PRESSURE MEASUREMENT
    Radchenko, G.
    Sirenko, Y.
    Polischuk, S.
    [J]. JOURNAL OF HYPERTENSION, 2010, 28 : E253 - E253
  • [5] Unattended Automated Office Blood Pressure Compared to Loaned Self-Blood Pressure Measurement in Hypertensive Patients
    Vega Ramirez, Jose R.
    Calvo Vargas, Cesar G.
    [J]. HYPERTENSION, 2018, 72
  • [6] AUTOMATED OFFICE BLOOD PRESSURE COMPARED TO MANUAL OFFICE BLOOD PRESSURE AND TO HOME BLOOD PRESSURE IN HYPERTENSIVE SUBJECTS
    Filipovsky, J.
    Seidlerova, J. Mlikova
    Vagovicova, P.
    Mayer, O., Jr.
    Kratochvil, Z.
    [J]. JOURNAL OF HYPERTENSION, 2015, 33 : E411 - E411
  • [7] Multiple office blood pressure measurement is not inferior to home blood pressure monitoring compared with 24-hour ambulatory blood pressure monitoring: a prospective multicenter study
    Choi, T. Y.
    Rhee, M. Y.
    Park, H. B.
    Kim, J. H.
    Namgung, J.
    Lee, S. Y.
    Cho, D. K.
    Kim, S. Y.
    Kim, J. Y.
    Park, J. S.
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 : 674 - 675
  • [8] A comparison of office blood pressure, telemedical home blood pressure and ambulatory blood pressure monitoring
    Hoffmann-Petersen, N.
    Tambo, T.
    Pedersen, E. Bjerregaard
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 573 - 573
  • [9] Out-of-Office Blood Pressure Monitoring: A Comparison of Ambulatory Blood Pressure Monitoring and Home (Self) Monitoring Of Blood Pressure
    Townsend, Raymond R.
    [J]. HYPERTENSION, 2020, 76 (06) : 1667 - 1673
  • [10] Home blood pressure measurements: Advantages and disadvantages compared to office and ambulatory monitoring
    Bonafini, Sara
    Fava, Cristiano
    [J]. BLOOD PRESSURE, 2015, 24 (06) : 325 - 332