A modified laser ablation-isotope ratio mass spectrometry method for in situ analysis of sulfur isotope composition of sulfides

被引:0
|
作者
Guo, Dongwei [1 ,2 ]
Fan, Changfu [1 ,4 ]
Hu, Bin [1 ,4 ]
Li, Yanhe [1 ]
Wu, Xiaopei [3 ]
Sun, Pengcheng [1 ]
Hou, Kejun [1 ]
Wang, Qian [1 ]
机构
[1] Chinese Acad Geol Sci, Inst Mineral Resources, Key Lab Metallogeny & Mineral Assessment, Minist Nat Resources, Beijing, Peoples R China
[2] Peking Univ, Sch Earth & Space Sci, Beijing, Peoples R China
[3] China Antidoping Agcy, Drug & Food Antidoping Lab, Beijing, Peoples R China
[4] Chinese Acad Geol Sci, Inst Mineral Resources, Key Lab Metallogeny & Mineral Assessment, Minist Nat Resources, Beijing 100037, Peoples R China
基金
中国国家自然科学基金;
关键词
HIGH-PRECISION; MULTISULFUR ISOTOPES; ELEMENTAL SULFUR; ICP-MS; DELTA-S-34; FRACTIONATION; MINERALS; SULFATE; CARBON; PYRITE;
D O I
10.1002/rcm.9707
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleA novel laser ablation-isotope ratio mass spectrometry (LA-IRMS) method for in situ analysis of sulfur isotopes in sulfides has been developed. Instead of the in situ reaction applied by the traditional laser microprobe, the analyte gas preparation in this method is separated temporally and spatially from the LA, resulting in improved precision and accuracy.MethodsOur LA-IRMS system combines an ultraviolet LA system, an elemental analyzer (EA), a custom-built cryogenic concentration system, a continuous-flow interface, and an IRMS. The sulfide aerosol particles generated from LA were transferred by a helium carrier gas from the ablation cell into the reaction tube and were then converted into SO2. Subsequently, SO2 was enriched in two cold traps and was finally introduced into the ion source of the IRMS through the continuous-flow interface.ResultsWe measured three synthetic and four natural sulfide reference materials to test the performance of this method. Precisions of +/- 0.25 parts per thousand-+/- 0.48 parts per thousand and +/- 0.32 parts per thousand-+/- 0.64 parts per thousand (1SD, n = 5) for delta 34S values of synthetic and natural sulfide standards can be obtained for spot sizes ranging from 64 to 80 mu m. Measured values and their recommended values showed a good linear relationship (R2 within 0.998 and 0.9995) with the slope of approaching unity (within 1.0509 and 1.1313).ConclusionsData from the measurement of reference materials showed that the precision and accuracy of our method were satisfactory. This method is a powerful tool for in situ sulfur isotope measurement of sulfides and can be further applied to in situ carbon and oxygen isotope analyses.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] In Situ Carbon Stable isotope Analysis of Organic Carbon by Laser Ablation-Isotope Ratio Mass Spectrometry
    ZHANG H.
    WEI L.
    LIAO X.
    WANG J.-N.
    SHI Q.-Y.
    ZHANG X.
    [J]. Chinese Journal of Analytical Chemistry, 2020, 48 (06): : 774 - 779
  • [2] In Situ Carbon Stable Isotope Analysis of Organic Carbon by Laser Ablation-Isotope Ratio Mass Spectrometry
    Zhang, Han
    Wei, Lai
    Liao, Xu
    Wang, Jia-Ni
    Shi, Qiu-Yue
    Zhang, Xian
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (06) : 774 - 779
  • [3] Excimer laser isotope-ratio-monitoring mass spectrometry for in situ oxygen isotope analysis
    Wiechert, U
    Fiebig, J
    Przybilla, R
    Xiao, Y
    Hoefs, J
    [J]. CHEMICAL GEOLOGY, 2002, 182 (2-4) : 179 - 194
  • [4] Analysis of In situ Pb Isotope in Sulfides by Laser Ablation Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang Wen
    Hu Zhao-Chu
    Jin Zhen-Min
    Liu Yong-Sheng
    Ling Wen-Li
    Hu Qing-Hai
    Fu Jia-Li
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (01) : 14 - 22
  • [5] DEVELOPMENT OF A METHOD FOR ACCURATE DETERMINATION OF TRIPLE SULFUR ISOTOPE RATIOS OF SULFIDE MINERALS IN METEORITES BY LASER ABLATION AND ISOTOPE RATIO MASS SPECTROMETRY
    Ignatev, A. V.
    Velivetckaia, T. A.
    [J]. METEORITICS & PLANETARY SCIENCE, 2014, 49 : A181 - A181
  • [6] Laser ablation isotope ratio mass spectrometry for enhanced sensitivity and spatial resolution in stable isotope analysis
    Moran, James J.
    Newburn, Matt K.
    Alexander, M. Lizabeth
    Sams, Robert L.
    Kelly, James F.
    Kreuzer, Helen W.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (09) : 1282 - 1290
  • [7] Laser Ablation Inductively Coupled Mass Spectrometry for in situ Trace Element and Isotope Analysis
    Ash, R. D.
    [J]. MICROSCOPY AND MICROANALYSIS, 2009, 15 : 538 - 539
  • [8] An improved in situ technique for the analysis of the Os isotope ratio in sulfides using laser ablation-multiple ion counter inductively coupled plasma mass spectrometry
    Zhu, Lu-Yun
    Liu, Yong-Sheng
    Jiang, Shao-Yong
    Lin, Jie
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (08) : 1546 - 1552
  • [9] In situ sulfur isotope analysis by laser ablation MC-ICPMS
    Bendall, C
    Lahaye, Y
    Fiebig, J
    Weyer, S
    Brey, GP
    [J]. APPLIED GEOCHEMISTRY, 2006, 21 (05) : 782 - 787
  • [10] Laser ablation split stream for in situ sulfur isotope and elemental analysis
    Oelze, Marcus
    Frick, Daniel A.
    Gleeson, Sarah A.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (06) : 1118 - 1124