Reconstruction of the mid-position image using NiftyReg and verification of the mid-position

被引:0
|
作者
Carlin, A. [1 ]
Grimes, H. [2 ]
McClelland, J. R. [3 ]
Eiben, B. [4 ,5 ]
Gillies, C. [6 ]
机构
[1] Barts Hlth NHS Trust, Radiotherapy Phys, London, England
[2] Univ Coll London NHS Fdn Trust, Radiotherapy Phys, London, England
[3] UCL, Dept Med Phys & Biomed Engn, Ctr Med Image Comp, London, England
[4] Inst Canc Res, London, England
[5] Royal Marsden NHS Fdn Trust, Joint Dept Phys, London, England
[6] Univ Coll London NHS Fdn Trust, Radiotherapy Phys Serv, London, England
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PO-1685
引用
收藏
页码:S1395 / S1396
页数:2
相关论文
共 50 条
  • [1] Comparison of mid-position CT reconstruction systems
    Pereira, M.
    Stroom, J.
    Ghareeb, F.
    Boukerroui, D.
    Gooding, M. J.
    Greco, C.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1387 - S1388
  • [2] THE MID-POSITION PHENOMENON IN EYE MOVEMENTS
    WEINSTEIN, EA
    BENDER, MB
    TRANSACTIONS OF THE AMERICAN NEUROLOGICAL ASSOCIATION, 1948, : 163 - 165
  • [3] Improving spatial fidelity and image quality of mid-position MRI for lung radiotherapy
    van Bochove, A.
    Keijnemans, K.
    Borman, P.
    van Lier, A.
    Fast, M.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S49 - S50
  • [4] Validation of the mid-position strategy for lung tumors in helical TomoTherapy
    Wanet, Marie
    Sterpin, Edmond
    Janssens, Guillaume
    Delor, Antoine
    Lee, John Aldo
    Geets, Xavier
    RADIOTHERAPY AND ONCOLOGY, 2014, 110 (03) : 529 - 537
  • [5] VALIDATION OF A MID-POSITION PET SCAN FOR TREATMENT PLANNING IN RADIOTHERAPY
    Kruis, M.
    Kabli, S.
    Sonke, J. J.
    van Herk, M.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S122 - S123
  • [6] Experiments to validate a Mid-Position workflow: Results with two independent implementations
    Jackson, E.
    Boukerroui, D.
    Gooding, M. J.
    Remeijer, P.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1573 - S1574
  • [7] Registration accuracy and image quality of time averaged mid-position CT scans for liver SBRT
    Kruis, Matthijs F.
    van de Kamer, Jeroen B.
    Sonke, Jan-Jakob
    Jansen, Edwin P. M.
    van Herk, Marcel
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 404 - 408
  • [8] MRI-guided mid-position liver radiotherapy: Validation of image processing and registration steps
    van de Lindt, T. N.
    van Kranen, S. R.
    Nowee, M. E.
    Jansen, E. P. M.
    van der Heide, U. A.
    Sonke, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 138 : 132 - 140
  • [9] Mid-position treatment strategy for locally advanced lung cancer: a dosimetric study
    Ayadi, M.
    Baudier, T.
    Bouilhol, G.
    Dupuis, P.
    Boissard, P.
    Pinho, R.
    Krason, A.
    Rit, S.
    Claude, L.
    Sarrut, D.
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1110):
  • [10] Dosimetric benefits of mid-position approach compared with internal target volume for esophageal RT
    Jin, P.
    Machiels, M.
    Crama, K. F.
    Visser, J.
    Van Wieringen, N.
    Bel, A.
    Alderliesten, T.
    Hulshof, M. C. C. M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1042 - S1043