DCT-Net: An effective method to diagnose retinal tears from B-scan ultrasound images

被引:0
|
作者
Li, Ke [1 ]
Zhu, Qiaolin [3 ]
Wu, Jianzhang [2 ,3 ]
Ding, Juntao [1 ]
Liu, Bo [1 ]
Zhu, Xixi [3 ]
Lin, Shishi [3 ]
Yan, Wentao [3 ]
Li, Wulan [1 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 1, Wenzhou 325035, Peoples R China
[2] Oujiang Lab, Zhejiang Lab Regenerat Med Vis & Brain Hlth, Wenzhou 325000, Peoples R China
[3] Wenzhou Med Univ, Eye Hosp, Sch Ophthalmol & Optometry, Wenzhou 325027, Peoples R China
基金
国家重点研发计划;
关键词
retinal tears; ultrasound image; automatic diagnosis; vision transformer; attention rollout; CONVOLUTIONAL NEURAL-NETWORKS; ULTRASONOGRAPHY;
D O I
10.3934/mbe.2024046
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Retinal tears (RTs) are usually detected by B-scan ultrasound images, particularly for individuals with complex eye conditions. However, traditional manual techniques for reading ultrasound images have the potential to overlook or inaccurately diagnose conditions. Thus, the development of rapid and accurate approaches for the diagnosis of an RT is highly important and urgent. The present study introduces a novel hybrid deep-learning model called DCT-Net to enable the automatic and precise diagnosis of RTs. The implemented model utilizes a vision transformer as the backbone and feature extractor. Additionally, in order to accommodate the edge characteristics of the lesion areas, a novel module called the residual deformable convolution has been incorporated. Furthermore, normalization is employed to mitigate the issue of overfitting and, a Softmax layer has been included to achieve the final classification following the acquisition of the global and local representations. The study was conducted by using both our proprietary dataset and a publicly available dataset. In addition, interpretability of the trained model was assessed by generating attention maps using the attention rollout approach. On the private dataset, the model demonstrated a high level of performance, with an accuracy of 97.78%, precision of 97.34%, recall rate of 97.13%, and an F1 score of 0.9682. On the other hand, the model developed by using the public funds image dataset demonstrated an accuracy of 83.82%, a sensitivity of 82.69% and a specificity of 82.40%. The findings, therefore present a novel framework for the diagnosis of RTs that is characterized by a high degree of efficiency, accuracy and interpretability. Accordingly, the technology exhibits considerable promise and has the potential to serve as a reliable tool for ophthalmologists.
引用
收藏
页码:1110 / 1124
页数:15
相关论文
共 50 条
  • [1] THE USE OF DYNAMIC ULTRASOUND B-SCAN TO DETECT RETINAL TEARS IN SPONTANEOUS VITREOUS HEMORRHAGE
    NISCHAL, KK
    JAMES, JN
    MCALLISTER, J
    [J]. EYE, 1995, 9 : 502 - 506
  • [2] ESTIMATION OF PULSES IN ULTRASOUND B-SCAN IMAGES
    JENSEN, JA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (02) : 164 - 172
  • [3] Predominantly Superior Retinal Tears Detected by B-Scan Ultrasonography
    Streho, M.
    Perrenoud, F.
    Abraham, N.
    Hawa, K.
    Puech, M.
    Giocanti-Auregan, A.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [4] DIAGNOSIS OF RETINAL-DETACHMENT WITH B-SCAN ULTRASOUND
    JACK, RL
    COLEMAN, DJ
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1973, 8 (01): : 10 - 18
  • [5] CONTRAST-RESOLUTION ANALYSIS OF ULTRASOUND B-SCAN IMAGES
    LOPEZ, H
    SMITH, SW
    CLAYMAN, W
    [J]. ULTRASONIC IMAGING, 1981, 3 (02) : 196 - 196
  • [6] A method of extracting contour in B-scan ultrasonic images
    Song, GD
    Zhang, H
    [J]. ELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY III, 2002, 4925 : 270 - 274
  • [7] A WAVEFIELD EXTRAPOLATION METHOD FOR SIMULATING B-SCAN IMAGES
    FINETTE, S
    [J]. ULTRASONIC IMAGING, 1987, 9 (03) : 171 - 179
  • [8] DETECTION OF RETINAL DETACHMENTS SECONDARY TO CHOROIDAL MELANOMA WITH B-SCAN ULTRASOUND
    JACK, RL
    COLEMAN, DJ
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1972, 74 (06) : 1057 - 1065
  • [9] TISSUE CHARACTERIZATION FROM ULTRASOUND B-SCAN DATA
    NICHOLAS, D
    NASSIRI, DK
    GARBUTT, P
    HILL, CR
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (02): : 135 - 143
  • [10] MEASUREMENT OF FETAL BODY DIMENSIONS BY ULTRASOUND B-SCAN METHOD
    YLOSTALO, P
    [J]. ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1974, 63 (01) : 20 - 23