Cracking Pattern and Bearing Capacity of Steel Fiber-Reinforced Concrete Single-Layer Tunnel Lining

被引:2
|
作者
Li, Huayun [1 ]
Wu, Yangfan [1 ]
Zhou, Anxiang [1 ]
Lu, Feng [2 ,3 ]
Lei, Zhongcheng [4 ]
Zeng, Bowen [5 ]
Zhu, Kaicheng [1 ]
机构
[1] Xihua Univ, Sch Architecture & Civil Engn, Chengdu 610039, Peoples R China
[2] Xihua Univ, Sch Emergency Management, Chengdu 610039, Peoples R China
[3] Southwest Jiaotong Univ, Sch Civil Engn, Key Lab Transportat Tunnel Engn, Minist Educ, Chengdu 610031, Peoples R China
[4] Shenzhen Municipal Design & Res Inst Co Ltd, Shenzhen 518029, Peoples R China
[5] Univ Alberta, Dept Civil & Environm Engn, Edmonton, AB T6G 2E9, Canada
基金
中国国家自然科学基金;
关键词
tunnel; single-layer lining; steel fiber-reinforced concrete; similar model test; cracking pattern; MECHANICAL-PROPERTIES; PERFORMANCE; BEHAVIOR;
D O I
10.3390/su151310665
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In recent years, steel fiber-reinforced concrete (SFRC) single-layer linings have been used in tunnel engineering. Compared to plain concrete single-layer linings, SFRC single-layer linings demonstrate enhanced bearing capacity, durability, and sustainability. Existing studies primarily focused on the mechanical properties of SFRC; however, limited investigations have been conducted on the cracking pattern of SFRC linings. This study uses laboratory tests to examine the influence of steel fiber content and aspect ratio on the mechanical properties of concrete, such as compressive strength and elastic modulus. After the recommended content and aspect ratio of steel fiber are proposed through tests, the cracking pattern and safety performance of plain concrete and SFRC linings under surrounding rock pressure are studied using a similar model test. The test results indicate that the recommended steel fiber volume fraction and aspect ratio for CF35 SFRC are 0.58% and 70, respectively. Due to the effect of loose load, cracks initially develop on the inside of arch crowns in both plain concrete and SFRC single-layer linings. Subsequently, new cracks appear on the inside of the lining floor and the outside of the two wall feet. Numerous narrow cracks with rugged and winding expansion paths can be found on SFRC single-layer linings. Conversely, plain concrete single-layer linings exhibit fewer cracks with larger widths along a straighter path. The initial cracking load of a single-layer lining made of plain concrete is 0.027 MPa, whereas for a single-layer lining made of SFRC, it is 0.04 MPa. This indicates that SFRC can effectively enhance the initial cracking load of lining structures. In the event of damage to the lining, the most critical area for the plain concrete single-layer lining is at the two wall feet, where the minimum safety factor is 1.66. However, for the SFRC lining in the same location, the safety factor is 2.7, resulting in a 62.7% increase in safety.
引用
下载
收藏
页数:24
相关论文
共 50 条
  • [1] Experimental study on mechanical behavior of single-layer lining of steel fiber reinforced concrete tunnel considering interlayer effect
    Zhou, Ping
    Wang, Zhijie
    Lei, Feiya
    Du, Yanliang
    Hou, Weiming
    Xu, Haiyan
    Wang, Li
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2019, 52 (05): : 116 - 128
  • [2] Model tests on bearing characteristics of steel fiber-reinforced concrete lining of weak surrounding rock tunnel
    Cui G.-Y.
    Wang D.-Y.
    Ni S.-Z.
    Yuan J.-X.
    Ma J.-H.
    Zhu C.-A.
    Wang, Dao-Yuan (wtg-888@163.com), 1807, Chinese Society of Civil Engineering (39): : 1807 - 1813
  • [3] Experimental research on single-layer tunnel lining of steel fiber shotcrete
    Liu, Xin-Rong
    Zhu, Yun-Hua
    Li, Xiao-Hong
    Du, Guo-Ping
    Song, Zhan-Ping
    Yantu Lixue/Rock and Soil Mechanics, 2009, 30 (08): : 2319 - 2323
  • [4] Experimental research on single-layer tunnel lining of steel fiber shotcrete
    Liu Xin-rong
    Zhu Yun-hua
    Li Xiao-hong
    Du Guo-ping
    Song Zhan-ping
    ROCK AND SOIL MECHANICS, 2009, 30 (08) : 2319 - 2323
  • [5] Chloride Ion Penetration in Reinforced Concrete and Steel Fiber-Reinforced Concrete Precast Tunnel Lining Segments
    Abbas, Safeer
    Soliman, Ahmed M.
    Nehdi, Moncef L.
    ACI MATERIALS JOURNAL, 2014, 111 (06) : 613 - 622
  • [6] Fiber-Reinforced Sprayed Concrete as a Permanent Tunnel Lining
    Larive, Catherine
    Bouteille, Sebastien
    Berthoz, Nicolas
    Zappelli, Serge
    STRUCTURAL ENGINEERING INTERNATIONAL, 2020, 30 (04) : 498 - 505
  • [7] Steel Fiber-Reinforced Shotcreting in Tunnel Lining.
    Ruffert, Guenter
    Strassen- und Tiefbau, 1988, 42 (02): : 13 - 14
  • [8] Mechanical Performance of Reinforced Concrete and Steel Fiber-Reinforced Concrete Precast Tunnel Lining Segments: A Case Study
    Abbas, Safeer
    Soliman, Ahmed M.
    Nehdi, Moncef L.
    ACI MATERIALS JOURNAL, 2014, 111 (05) : 501 - 510
  • [9] Tension stiffening and cracking of steel fiber-reinforced concrete
    Bischoff, PH
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2003, 15 (02) : 174 - 182
  • [10] Capacity of steel fiber reinforced concrete for extruded concrete lining method
    Kawaguchi, H
    Nagasawa, Y
    Kurita, M
    Watanabe, M
    MODERN TUNNELING SCIENCE AND TECHNOLOGY, VOLS I AND II, 2001, : 845 - 850