Investigation on local geothermal energy attenuation after long-term operation of ground heat exchanger with considering aquifer effect

被引:7
|
作者
Ma, Z. D. [1 ]
Zhang, Y. P. [1 ,2 ]
Saw, L. H. [3 ]
Cui, X. [1 ]
Jia, G. S. [1 ]
Jin, L. W. [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Peoples R China
[2] Minist Nat Resources, Key Lab Coal Resources Explorat & Comprehens Utili, Xian 710021, Peoples R China
[3] Univ Tunku Abdul Rahman, Lee Kong Chian Fac Engn & Sci, Kajang 43000, Selangor, Malaysia
关键词
Aquifer layer; Aquifuge layer; Geothermal energy; Ground heat exchanger; Ground temperature field; EXTRACTION PERFORMANCE; ANALYTICAL-MODEL; PUMP SYSTEM; TEMPERATURE; FLOW; RECOVERY;
D O I
10.1016/j.geothermics.2022.102608
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The long-term operation of deep buried ground heat exchangers (GHE) for heat extraction would attenuate the local geothermal field. The variation of geothermal energy in the affected area over time is a subject worthy of dedicated study. In this paper, the heat transfer between GHE and surrounding geological strata including aquifuge and aquifer layers is modeled and numerically solved to investigate the variations of GHE performance and attenuation behaviors of ground temperature field. The results show that the reduction ratios of GHE performance in the aquifer and aquifuge layers between 1st and 8th years are 1.3% and 8.9%, respectively, due to the convective heat transfer induced by groundwater in the aquifer layer. The analysis of local temperature variation implies that the groundwater flow leads to the circumferential asymmetry of ground temperature reduction in aquifer layer, which also affects the temperature distribution in geological layers adjacent to the aquifer. The worst ground temperature recovery point appears on the borehole wall in the aquifuge layer, while it appears at a fixed position downstream in the aquifer layer. Taking the ground transient and initial temperature difference greater than 0.5 degrees C as the threshold to characterize the attenuation region, the geothermal field attenuation area of the eighth year in the aquifer is about 4.5 times that of the first year, while it is about 5.1 similar to 5.5 times that of the first year in the aquifuge layers. The analysis of variations of GHE performance and ground temperature field quantitatively evaluates geothermal attenuation behaviors in aquifer and aquifuge layers subject to the long-term operation of GHEs.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] REDUCTION OF HEAT GAINS TO GEOTHERMAL HEAT EXCHANGERS IN LONG-TERM OPERATION
    Polovnikov, Viacheslav Yu.
    Shelemekhova, Sofia D.
    [J]. BULLETIN OF THE TOMSK POLYTECHNIC UNIVERSITY-GEO ASSETS ENGINEERING, 2023, 334 (09): : 18 - 24
  • [2] Heat transfer in the ground with a horizontal heat exchanger installed - Long-term thermal effects
    Larwa, Barbara
    Kupiec, Krzysztof
    [J]. APPLIED THERMAL ENGINEERING, 2020, 164
  • [3] Finite Element Modeling of Geothermal Source of Heat Pump in Long-Term Operation
    Halaj, Elzbieta
    Pajak, Leszek
    Papiernik, Bartosz
    [J]. ENERGIES, 2020, 13 (06)
  • [4] Long-term global ground heat flux and continental heat storage from geothermal data
    Cuesta-Valero, Francisco Jose
    Garcia-Garcia, Almudena
    Beltrami, Hugo
    Fidel Gonzalez-Rouco, J.
    Garcia-Bustamante, Elena
    [J]. CLIMATE OF THE PAST, 2021, 17 (01) : 451 - 468
  • [5] The long-term operation and thermal disturbance investigation on a four-borehole-heat-exchanger residential heating system
    Liu, Wenjie
    Yao, Jian
    Jia, Teng
    Dai, Yanjun
    Zhu, Junjie
    Novakovic, Vojislav
    [J]. APPLIED THERMAL ENGINEERING, 2023, 219
  • [6] Heat transfer performance of a deep ground heat exchanger for building heating in long-term service
    Li, Chao
    Guan, Yanling
    Liu, Jianhong
    Jiang, Chao
    Yang, Ruitao
    Hou, Xueming
    [J]. RENEWABLE ENERGY, 2020, 166 : 20 - 34
  • [7] Electric and Energy Coupling for Long-Term Operation Considering Transmission Restrictions
    Andriolo R.F.
    Fernandes T.S.P.
    Bessa M.R.
    Bloot M.L.
    [J]. Journal of Control, Automation and Electrical Systems, 2015, 26 (6) : 686 - 700
  • [8] Collaborative Mission Planning for Long-Term Operation Considering Energy Limitations
    Li, Bingxi
    Page, Brian R.
    Moridian, Barzin
    Mahmoudian, Nina
    [J]. IEEE ROBOTICS AND AUTOMATION LETTERS, 2020, 5 (03) : 4751 - 4758
  • [9] A comprehensive investigation on U-tube ground heat exchanger performance considering insulation layer in deep geothermal system
    Xu, Ningning
    He, Miao
    Xu, Mingbiao
    Chen, Huan
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2022, 34
  • [10] A comprehensive investigation on U-tube ground heat exchanger performance considering insulation layer in deep geothermal system
    Xu, Ningning
    He, Miao
    Xu, Mingbiao
    Chen, Huan
    [J]. Case Studies in Thermal Engineering, 2022, 34