Superparamagnetic iron oxide nanoparticle enhanced percutaneous microwave ablation: Ex-vivo characterization using magnetic resonance thermometry

被引:0
|
作者
Bhagavatula, Sharath K. [1 ,4 ,5 ]
Panikkanvalappil, Sajanlal R. [2 ,3 ]
Tokuda, Junichi [1 ]
Levesque, Vincent [1 ]
Tatarova, Zuzana [1 ]
Liu, Guigen [1 ]
Markert, John E. [1 ]
Jonas, Oliver [1 ,6 ,7 ]
机构
[1] Harvard Med Sch, Brigham & Womens Hosp, Dept Radiol, Boston, MA USA
[2] Dana Farber Canc Inst, Dept Imaging, Boston, MA USA
[3] Harvard Med Sch, Boston, MA USA
[4] Harvard Med Sch, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
[5] Brigham & Womens Hosp, 75 Francis St, Boston, MA 02115 USA
[6] Harvard Med Sch, Dept Radiol, 221 Longwood Ave, Boston, MA 02115 USA
[7] Brigham & Womens Hosp, 221 Longwood Ave, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
interventional radiology; magnetic resonance thermometry; microwave ablation; minimally invasive treatment; superparamagnetic iron oxide nanoparticles; LIVER; FERUMOXYTOL; DEVICES; TUMORS;
D O I
10.1002/mp.17040
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Percutaneous microwave ablation (pMWA) is a minimally invasive procedure that uses a microwave antenna placed at the tip of a needle to induce lethal tissue heating. It can treat cancer and other diseases with lower morbidity than conventional surgery, but one major limitation is the lack of control over the heating region around the ablation needle. Superparamagnetic iron oxide nanoparticles have the potential to enhance and control pMWA heating due to their ability to absorb microwave energy and their ease of local delivery. Purpose: The purpose of this study is to experimentally quantify the capabilities of FDA-approved superparamagnetic iron oxide Feraheme nanoparticles (FHNPs) to enhance and control pMWA heating. This study aims to determine the effectiveness of locally injected FHNPs in increasing the maximum temperature during pMWA and to investigate the ability of FHNPs to create a controlled ablation zone around the pMWA needle. Methods: PMWA was performed using a clinical ablation system at 915 MHz in ex-vivo porcine liver tissues. Prior to ablation, 50 uL 5 mg/mL FHNP injections were made on one side of the pMWA needle via a 23-gauge needle. Local temperatures at the FHNP injection site were directly compared to equidistant control sites without FHNP. First, temperatures were compared using directly inserted thermocouples. Next, temperatures were measured non-invasively using magnetic resonance thermometry (MRT), which enabled comprehensive four-dimensional (volumetric and temporal) assessment of heating effects relative to nanoparticle distribution, which was quantified using dual-echo ultrashort echo time (UTE) subtraction MR imaging. Maximum heating within FHNP-exposed tissues versus control tissues were compared at multiple pMWA energy delivery settings. The ability to generate a controlled asymmetric ablation zone using multiple FHNP injections was also tested. Finally, intra-procedural MRT-derived heat maps were correlated with gold standard gross pathology using Dice similarity analysis. Results: Maximum temperatures at the FHNP injection site were significantly higher than control (without FHNP) sites when measured using direct thermocouples (93.1 +/- 6.0 degrees C vs. 57.2 +/- 8.1 degrees C, p = 0.002) and using non-invasive MRT (115.6 +/- 13.4 degrees C vs. 49.0 +/- 10.6 degrees C, p = 0.02). Temperature difference between FHNP-exposed and control sites correlated with total energy deposition: 66.6 +/- 17.6 degrees C, 58.1 +/- 8.5 degrees C, and 20.8 +/- 9.2 degrees C at high (17.5 +/- 2.2 kJ), medium (13.6 +/- 1.8 kJ), and low (8.8 +/- 1.1 kJ) energies, respectively (all pairwise p < 0.05). Each FHNP injection resulted in a nanoparticle distribution within 0.9 +/- 0.2 cm radially of the injection site and a local lethal heating zone confined to within 1.1 +/- 0.4 cm radially of the injection epicenter. Multiple injections enabled a controllable, asymmetric ablation zone to be generated around the ablation needle, with maximal ablation radius on the FHNP injection side of 1.6 +/- 0.2 cm compared to 0.7 +/- 0.2 cm on the non-FHNP side (p = 0.02). MRT intra-procedural predicted ablation zone correlated strongly with post procedure gold-standard gross pathology assessment (Dice similarity 0.9). Conclusions: Locally injected FHNPs significantly enhanced pMWA heating in liver tissues, and were able to control the ablation zone shape around a pMWA needle. MRI and MRT allowed volumetric real-time visualization of both FHNP distribution and FHNP-enhanced pMWA heating that was useful for intra-procedural monitoring. This work strongly supports further development of a FHNP-enhanced pMWA paradigm; as all individual components of this approach are approved for patient use, there is low barrier for clinical translation.
引用
收藏
页码:3195 / 3206
页数:12
相关论文
共 50 条
  • [31] Magnetic resonance characterization of the esophagus and small intestine using a flexible MRI catheter: An ex-vivo study in pigs.
    Hasharoni, K
    Sicron, N
    Beiln, S
    Golan, E
    Jacob, H
    GASTROENTEROLOGY, 2005, 128 (04) : A404 - A404
  • [32] Evaluating the Severity of Nonalcoholic Steatohepatitis With Superparamagnetic Iron Oxide-Enhanced Magnetic Resonance Imaging
    Tornita, Kengo
    Tanimoto, Akihiro
    Irie, Rie
    Kikuchi, Masahiro
    Yokoyama, Hirokazu
    Teratani, Toshiaki
    Suzuki, Takahiro
    Taguchi, Takashi
    Noguchi, Masaaki
    Ohkura, Tamiko
    Hibi, Toshifumi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (06) : 1444 - 1450
  • [33] Ultrasmall superparamagnetic iron oxide-enhanced magnetic resonance Imaging in experimental autoimmune encephalitis
    Bendszus, M
    Stoll, G
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (06) : 850 - 850
  • [34] Magnetic resonance imaging (MRI) enhanced with superparamagnetic iron oxide (SPIO) for assessing liver function
    Nagashima, I
    Takada, T
    Okinaga, K
    Takada, K
    Takeshita, K
    Furui, S
    GASTROENTEROLOGY, 2004, 126 (04) : A429 - A430
  • [35] Superparamagnetic iron oxide-enhanced magnetic resonance for imaging cardiac inflammation. A minireview
    Podrouzkova, Helena
    Feitova, Vera
    Panovsky, Roman
    Meluzin, Jaroslav
    Orban, Marek
    BIOMEDICAL PAPERS-OLOMOUC, 2015, 159 (03): : 378 - 381
  • [36] Detection and characterization of focal hepatic lesions: Mangafodipir vs. superparamagnetic iron oxide-enhanced magnetic resonance imaging
    Kim, MJ
    Kim, JH
    Lim, JS
    Oh, YT
    Chung, JJ
    Choi, JS
    Lee, WJ
    Kim, KW
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (04) : 612 - 621
  • [37] Transferrin-Conjugated Superparamagnetic Iron Oxide Nanoparticles as In Vivo Magnetic Resonance Imaging Contrast Agents
    Wang, Jun
    Zhang, Baolin
    Yang, Gao
    Su, Lichao
    Wang, Lei
    Gao, Fabao
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2020, 20 (04) : 2018 - 2024
  • [38] Specific targeting of gliomas with multifunctional superparamagnetic iron oxide nanoparticle optical and magnetic resonance imaging contrast agents
    Meng, Xiang-xi
    Wan, Jia-qi
    Jing, Meng
    Zhao, Shi-guang
    Cai, Wei
    Liu, En-zhong
    ACTA PHARMACOLOGICA SINICA, 2007, 28 (12) : 2019 - 2026
  • [39] Amphiphilic starlike dextran wrapped superparamagnetic iron oxide nanoparticle clsuters as effective magnetic resonance imaging probes
    Su, Hongying
    Liu, Yanhong
    Wang, Dan
    Wu, Changqiang
    Xia, Chunchao
    Gong, Qiyong
    Song, Bin
    Ai, Hua
    BIOMATERIALS, 2013, 34 (04) : 1193 - 1203
  • [40] Specific targeting of gliomas with multifunctional superparamagnetic iron oxide nanoparticle optical and magnetic resonance imaging contrast agents
    Xiang-xi Meng
    Jia-qi Wan
    Meng Jing
    Shi-guang Zhao
    Wei Cai
    En-zhong Liu
    Acta Pharmacologica Sinica, 2007, 28 : 2019 - 2026