A magnetocaloric air-conditioning system prototype

被引:12
|
作者
Peixer, Guilherme F. [1 ]
Silva, Maria C. R. [1 ]
Lorenzoni, Anderson [1 ]
Hoffmann, Gislaine [1 ]
dos Santos, Diego [1 ]
do Rosario, Gabriel M. [1 ]
Pagnan, Elias [1 ]
Teza, Higor F. [1 ]
Silva, Pedro M. [1 ]
Dutra, Sergio L. [1 ]
Ribeiro, Marcelo C. [1 ]
Rosa, Marcelo A. A. [2 ]
Doring, Allan [3 ]
Vieira, Bernardo P. [1 ]
Nakashima, Alan T. D. [1 ]
Wendhausen, Paulo A. P. [2 ]
Teixeira, Cristiano S. [3 ]
Lozano, Jaime A. [1 ]
Barbosa Jr, Jader R. [1 ]
机构
[1] Univ Fed Santa Catarina, Res Labs Emerging Technol Cooling & Thermophys, POLO, Dept Mech Engn, BR-88040970 Florianopolis, SC, Brazil
[2] Fed Univ Santa Catarina UFSC, Dept Mech Engn, MAGMA Magnet Mat Grp, BR-88040900 Florianopolis, SC, Brazil
[3] Fed Univ Santa Catarina UFSC, Dept Mat Engn, Lab Magnetism & Magnet Mat, Lab3M, BR-89036256 Blumenau, SC, Brazil
关键词
Magnetic refrigeration; Airconditioning; Performance evaluation; System optimization; ACTIVE MAGNETIC REGENERATOR; PERFORMANCE; REFRIGERATOR; DESIGN;
D O I
10.1016/j.ijrefrig.2023.03.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper discusses the design procedure and first results of a large-scale magnetic air-conditioning system prototype demonstrated in a relevant environment compatible with the Technology Readiness Level (TRL) 6. The prototype, which contains all components of a functional cooling system, was experimentally evaluated in an especially developed calibrated calorimeter designed according to international technical standards for testing split-type air-conditioning units. The proposed experimental analysis is one of the first to quantify the impact of external losses associated with the heat exchangers on the cooling system performance. For outdoor and indoor temperatures fixed at 35 and 27 degrees C, respectively, the coefficient of performance disregarding thermal, flow and mechanical losses beyond the limits of the active magnetic regenerator was 5.72, corresponding to a second-law efficiency of 20.7%. When these losses and other essential operating variables, such as the heat exchanger fan power and the valve power consumption, are included, one-order-of-magnitude reductions are observed in the performance parameters, indicating that they should not be neglected in realistic assessments of not-in-kind cooling technologies.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [1] INTEGRAL OPTIMISATION OF A MAGNETOCALORIC AIR-CONDITIONING SYSTEM FOR AN ELECTRIC VEHICLE
    Torregrosa-Jaime, B.
    Paya, J.
    Corberan, J. M.
    [J]. 7TH INTERNATIONAL CONFERENCE ON MAGNETIC REFRIGERATION AT ROOM TEMPERATURE, 2016, : 244 - 247
  • [2] Application of Magnetocaloric Heat Pumps in Mobile Air-Conditioning
    Torregrosa-Jaime, Barbara
    Vasile, Carmen
    Risser, Michel
    Muller, Christian
    Corberan, Jose
    Paya, Jorge
    [J]. SAE INTERNATIONAL JOURNAL OF PASSENGER CARS-MECHANICAL SYSTEMS, 2013, 6 (02): : 520 - 528
  • [3] The desiccant air-conditioning system
    [J]. Riffat, S.B., 1600, Ambient Press Ltd (25):
  • [4] UNDERGROUND AIR-CONDITIONING SYSTEM
    不详
    [J]. REFRIGERATION AND AIR CONDITIONING, 1972, 75 (891): : 84 - &
  • [5] PLANNING AN AIR-CONDITIONING SYSTEM
    BLIND, G
    BLIND, D
    [J]. VETERINARY ECONOMICS, 1978, 19 (07): : 24 - 26
  • [6] AIR-CONDITIONING - SYSTEM SIZING
    ABRAMS, DW
    [J]. SOLAR AGE, 1983, 8 (01): : 56 - 56
  • [7] CINEMA AIR-CONDITIONING SYSTEM
    不详
    [J]. REFRIGERATION AND AIR CONDITIONING, 1973, 76 (904): : 85 - &
  • [8] MOISTURE IN THE AIR-CONDITIONING SYSTEM
    不详
    [J]. NORSK SKOGINDUSTRI, 1979, 33 (12): : 318 - 318
  • [9] A Magnetocaloric Booster Unit for Energy-Efficient Air-Conditioning
    Krautz, Maria
    Beyer, Maximilian
    Jaeschke, Christian
    Schinke, Lars
    Waske, Anja
    Seifert, Joachim
    [J]. CRYSTALS, 2019, 9 (02):
  • [10] Performance of a heat-regenerative adsorption air-conditioning prototype
    Gui, Yu-Bin
    Wang, Ru-Zhu
    Wu, Jing-Yi
    Xu, Yu-Xiong
    [J]. Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2002, 36 (02): : 173 - 175