Novel scoring system derived from meta-analysis and validated in cohort population for predicting 1-year atrial fibrillation recurrence after cryoballoon catheter ablation: The HeLPS-Cryo score

被引:1
|
作者
Waranugraha, Yoga [1 ]
Hsu, Jung-Chi [2 ]
Lin, Ting-Tse [3 ]
Ho, Li-Ting [3 ]
Yu, Chih-Chieh [3 ]
Liu, Yen-Bin [3 ]
Lin, Lian-Yu [3 ,4 ,5 ]
机构
[1] Univ Brawijaya, Univ Brawijaya Hosp, Fac Med, Dept Cardiol & Vasc Med, Malang, Indonesia
[2] Natl Taiwan Univ, Dept Internal Med, Div Cardiol, Jinshan Branch, New Taipei City, Taiwan
[3] Natl Taiwan Univ, Coll Med, Dept Internal Med, Div Cardiol,Natl Taiwan Univ Hosp, Taipei, Taiwan
[4] Natl Taiwan Univ Hosp, Yunlin Branch, Dept Internal Med, Yunlin, Taiwan
[5] Natl Taiwan Univ, Coll Med & Hosp, Dept Internal Med, Div Cardiol,Natl Taiwan Univ Hosp, 7 Chung Shan South Rd, Taipei 100, Taiwan
来源
关键词
atrial fibrillation; cryoballoon catheter ablation; HeLPS-Cryo score; RADIOFREQUENCY ABLATION; OUTCOMES; PATHOPHYSIOLOGY; CRYOABLATION;
D O I
10.1111/pace.14922
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atrial fibrillation (AF) recurrence rates in 1 year after cryoballoon ablation catheter (CBCA) are still high. We purposed to identify strong predictors for AF recurrence after the successful CBCA procedure and develop a new scoring system based only on pre-procedural parameters. Methods: In the derivation phase, a systematic review and meta-analysis identified the strong predictors of AF recurrence after the CBCA. The pooled hazard ratio (HR) was used to create the new scoring system. The second phase validated the new scoring system in the cohort population. Results: A meta-analysis including 29 cohort studies with 16196 participants confirmed that persistent AF, stroke, heart failure, and left atrial diameter (LAD) >40 mm were powerful predictors for AF recurrence after the CBCA procedure. The HeLPS-Cryo (heart failure [1], left atrial dilatation [1], persistent AF [2], and stroke [2]) was developed based on those pre-procedural predictors. It was validated in 140 patients receiving CBCA procedures and revealed excellent predictive performance for 1-year AF recurrence (AUC = 0.8877; 95% CI = 0.8208 to 0.9546). The HeLPS-Cryo score of >= 3 could predict 1-year AF recurrence with sensitivity and specificity of 78.9% and 87.9%, respectively. The positive predictive value was 66.7%, and the negative predictive value was 93.1%. Conclusion: The HeLPS-Cryo score can help the physician estimate the probability of 1-year AF recurrence after the successful CBCA procedure. Patients with HeLPS-Cryo score <3 are good candidates for the CBCA procedure.
引用
收藏
页码:462 / 473
页数:12
相关论文
共 10 条
  • [1] Depression and recurrence of atrial fibrillation after catheter ablation: a meta-analysis of cohort studies
    Zhuo, Chuanjun
    Ji, Feng
    Lin, Xiaodong
    Jiang, Deguo
    Wang, Lina
    Tian, Hongjun
    Xu, Yong
    Liu, Sha
    Chen, Ce
    JOURNAL OF AFFECTIVE DISORDERS, 2020, 271 : 27 - 32
  • [2] Serum Homocysteine and Atrial Fibrillation Recurrence after Catheter Ablation: A Meta-Analysis of 11 Cohort Studies Involving 2147 Patients
    Li, Biao
    Zeng, Fang
    Zhao, Qiang
    HORMONE AND METABOLIC RESEARCH, 2025, 57 (03) : 177 - 188
  • [3] Impact of Gender on Atrial Fibrillation Recurrence After Catheter Ablation: A Meta-Analysis of Large Cohort Studies (&gt;1,000 Patients)
    Rahman, M. Rubayat
    Elmassry, Mohamed
    Paz, Pablo
    El Nawaa, Saif
    Mantilla, Barbara
    Vutthikraivit, Wasawat
    Rattanawong, Pattara
    Putthapiban, Prapaipan
    Ansari, Mohammad Mehdi
    Shurmur, Scott W.
    CIRCULATION, 2019, 140
  • [4] The Effect of Renin-Angiotensin System Inhibitors on the Recurrence of Atrial Fibrillation After Catheter Ablation A Systematic Review and Meta-Analysis
    Zhao, Jianqiang
    Chen, Miao
    Zhuo, Chengui
    Huang, Yuan
    Zheng, Liangrong
    Wang, Qiqi
    INTERNATIONAL HEART JOURNAL, 2020, 61 (06) : 1174 - 1182
  • [5] Utility of C2HEST Score in Predicting Recurrence of Atrial Fibrillation After Catheter Ablation: A Systematic Review and Meta-Analysis With Reconstructed Time-to-Event Data
    Turkmani, Mustafa
    Amin, Ahmed Mazen
    Baqal, Omar
    Al Barznji, Saman
    Salam, Donna
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B189 - B189
  • [6] Effects of Glucagon-Like Peptide 1 Receptor Agonists on Atrial Fibrillation Recurrence After Catheter Ablation: A Systematic Review and Meta-analysis
    Karakasis, Paschalis
    Fragakis, Nikolaos
    Patoulias, Dimitrios
    Theofilis, Panagiotis
    Kassimis, George
    Karamitsos, Theodoros
    El-Tanani, Mohamed
    Rizzo, Manfredi
    ADVANCES IN THERAPY, 2024, 41 (10) : 3749 - 3756
  • [7] Impact of Sodium-Glucose Cotransporter 2 Inhibitor on Recurrence After Catheter Ablation for Atrial Fibrillation in Patients With Diabetes: A Propensity-Score Matching Study and Meta-Analysis
    Zhao, Zixu
    Jiang, Chao
    He, Liu
    Zheng, Shiyue
    Wang, Yufeng
    Gao, Mingyang
    Lai, Yiwei
    Zhang, Jingrui
    Li, Mingxiao
    Dai, Wenli
    Zuo, Song
    Guo, Xueyuan
    Li, Songnan
    Jiang, Chenxi
    Liu, Nian
    Tang, Ribo
    Long, Deyong
    Du, Xin
    Sang, Caihua
    Dong, Jianzeng
    Ma, Changsheng
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (24):
  • [8] Antiarrhythmic Drug Use and Success Rates After Catheter Ablation for Atrial Fibrillation: Findings From the SMASH-AF Meta-Analysis Study Cohort
    Cluckey, Andrew
    Yunus, Fahd N.
    Leef, George C.
    Askari, Mariam
    Heidenreich, Paul
    Turakhia, Mintu P.
    Perino, Alexander C.
    CIRCULATION, 2017, 136
  • [9] A new scoring system: PAT2C2H score. Its clinical use and comparison with HATCH and CHA2DS2-VASc scores in predicting arrhythmia recurrence after cryoballoon ablation of paroxysmal atrial fibrillation
    Cay, Serkan
    Kara, Meryem
    Ozcan, Firat
    Ozeke, Ozcan
    Korkmaz, Ahmet
    Cetin, Hande
    Aksu, Tolga
    Topaloglu, Serkan
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (03) : 701 - 710
  • [10] A new scoring system: PAT2C2H score. Its clinical use and comparison with HATCH and CHA2DS2-VASc scores in predicting arrhythmia recurrence after cryoballoon ablation of paroxysmal atrial fibrillation
    Serkan Cay
    Meryem Kara
    Firat Ozcan
    Ozcan Ozeke
    Ahmet Korkmaz
    Hande Cetin
    Tolga Aksu
    Serkan Topaloglu
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 701 - 710