Vibration-current data fusion and gradient boosting classifier for enhanced stator fault diagnosis in three-phase permanent magnet synchronous motors

被引:13
|
作者
Al-Haddad, Luttfi A. [1 ]
Jaber, Alaa Abdulhady [2 ]
Hamzah, Mohsin N. [2 ]
Fayad, Mohammed A. [3 ]
机构
[1] Univ Technol Iraq, Training & Workshops Ctr, Baghdad, Iraq
[2] Univ Technol Iraq, Mech Engn Dept, Baghdad, Iraq
[3] Univ Technol Iraq, Energy & Renewable Energies Technol Ctr, Baghdad, Iraq
关键词
Electrical current; Fault diagnosis; Gradient boosting; PMSM; Vibration signal analysis; SHORT-CIRCUIT; DESIGN; ORANGE;
D O I
10.1007/s00202-023-02148-z
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Permanent magnet synchronous motors (PMSMs) are widely recognized for their precise control capabilities, making them indispensable in numerous industrial applications. Yet, their susceptibility to faults, particularly stator faults, can lead to severe operational challenges. Effective health monitoring and prompt fault detection are, therefore, pivotal for preserving the performance and lifespan of PMSMs. In this research, we delve into an innovative approach to fault diagnosis in PMSMs by fusing vibration and current data. For the experimental setup, stator faults were simulated as inter-turn short circuits. Comprehensive datasets encompassing three-phase current signals and vibration signals were acquired from the PMSM test rig. These datasets were subsequently processed into statistical features. Leveraging the information gain for feature selection, we discerned crucial attributes for the fault assessment. A gradient boosting-based machine learning model was then employed to distinguish between various fault states, utilizing the selected features. Our findings unveiled that the combined vibration-current data fusion approach stands out, achieving an impressive diagnostic accuracy of 90.7% and an area under the curve of 95.1%. This underscores the efficacy of data fusion in conjunction with gradient boosting for fault diagnosis. The methodology presented herein promises to pave the way for timely fault detection, enabling proactive maintenance regimes, and bolstering the reliability of PMSMs in critical industrial settings.
引用
收藏
页码:3253 / 3268
页数:16
相关论文
共 50 条
  • [1] Application of AdaBoost for stator fault diagnosis in three-phase permanent magnet synchronous motors based on vibration-current data fusion analysis
    Al-Haddad, Luttfi A.
    Shijer, Sameera Sadey
    Jaber, Alaa Abdulhady
    Al-Ani, Safaa Taha
    Al-Zubaidi, Ahmed A.
    Abd, Eyad Taha
    [J]. ELECTRICAL ENGINEERING, 2024, 106 (04) : 4527 - 4542
  • [2] Vibration and current dataset of three-phase permanent magnet synchronous motors with stator faults
    Jung, Wonho
    Yun, Sung-Hyun
    Lim, Yoon-Seop
    Cheong, Sungjin
    Park, Yong-Hwa
    [J]. DATA IN BRIEF, 2023, 47
  • [3] Three-phase fault current characteristics of permanent magnet synchronous generator
    Song, Guobing
    Chang, Zhongxue
    Wang, Chenqing
    Li, Duanzhen
    Dou, Minna
    Liu, Kai
    [J]. Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2015, 49 (10): : 1 - 7
  • [4] A hybrid current controller for dual three-phase permanent magnet synchronous motors
    Yuan, Feixiong
    Huang, Shenghua
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2014, 9 (02) : 214 - 218
  • [5] Fault tolerant direct torque control of three-phase permanent magnet synchronous motors
    Teng, Qingfang
    Zhu, Jianguo
    Wang, Tianshi
    Lei, Gang
    [J]. WSEAS Transactions on Systems, 2012, 11 (08): : 465 - 476
  • [6] Fault Tolerant Control and Reconfiguration for Three-Phase Permanent Magnet Synchronous Motors Drive
    Abassi, M.
    Khlaief, A.
    Saadaoui, O.
    Chaari, A.
    Boussak, M.
    [J]. 2016 4TH INTERNATIONAL CONFERENCE ON CONTROL ENGINEERING & INFORMATION TECHNOLOGY (CEIT), 2016,
  • [7] Average Current Method to Detect Open-Winding Fault of Three-Phase Permanent Magnet Synchronous Motors
    Chen, Hung-Chi
    Wu, Zhi-Xuan
    Li, Chung-Yi
    [J]. 2016 18TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'16 ECCE EUROPE), 2016,
  • [8] Pattern identification for eccentricity fault diagnosis in permanent magnet synchronous motors using stator current monitoring
    Ebrahimi, B. M.
    Faiz, J.
    Araabi, B. N.
    [J]. IET ELECTRIC POWER APPLICATIONS, 2010, 4 (06) : 418 - 430
  • [9] Current Control for Dual Three-Phase Permanent Magnet Synchronous Motors Accounting for Current Unbalance and Harmonics
    Hu, Yashan
    Zhu, Zi-Qiang
    Liu, Kan
    [J]. IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2014, 2 (02) : 272 - 284
  • [10] Diagnosis of Stator Asymmetry in Permanent Magnet Synchronous Motors Using Negative Sequence Current
    Benhadj Ammar, Akram
    Gritli, Yasser
    Benrejeb, Mohamed
    [J]. STUDIES IN INFORMATICS AND CONTROL, 2018, 27 (02): : 165 - 174