Performance of near-infrared light transillumination in the detection of occlusal caries lesions in deciduous teeth

被引:1
|
作者
Marcondes, Ana Paula Marcal [1 ]
de Campos, Priscila Hernandez [1 ]
Ribeiro, Caroline Santos [1 ]
de Novaes, Tatiane Fernandes [1 ]
Lussi, Adrian [2 ]
Diniz, Michele Baffi [1 ]
机构
[1] Cruzeiro do Sul Univ, Grad Program Dent, Rua Galvao Bueno 868, BR-01506000 Sao Paulo, SP, Brazil
[2] Univ Freiburg, Ctr Dent Med, Dept Operat Dent & Periodontol, Hugstetter Str 55, D-79106 Freiburg, Germany
关键词
Dental caries; Diagnosis; Deciduous tooth; Transillumination; Fluorescence; FLUORESCENCE-BASED METHODS; ICDAS-II; IN-VIVO; APPROXIMAL CARIES; VISUAL INSPECTION; PROXIMAL CARIES; RADIOGRAPHY; REPRODUCIBILITY; DIAGNOSIS; ACCURACY;
D O I
10.1016/j.pdpdt.2023.103744
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: This study compared the performance of near-infrared light transillumination (NILT; DIAGNOcam [DC]) in detecting occlusal caries lesions in deciduous molars with the performance of the International Caries Detection and Assessment System (ICDAS), digital radiographic method (RX) and laser fluorescence (DIAGNOdent pen [LFpen]). Methods: Fifty-seven extracted deciduous molars with no frank cavitation caries lesions were selected. One site per tooth was evaluated twice each by two examiners using all methods. Then, a histological examination was performed using a stereomicroscope. The performance of the methods was assessed with respect to two thresholds: D1 (all visible caries lesions affecting enamel) and D3 (caries lesions extended into dentin). Results: A weighted kappa and intraclass correlation coefficients were calculated for intra- and inter-observer reproducibilities, varying from 0.31 (RX) to 0.89 (LFpen). The intra-observer reproducibility at D1 and D3 thresholds varied from 0.51 (ICDAS) to 0.85 (DC) and from 0.30 (ICDAS) to 1.00 (RX), respectively. The interobserver reproducibility varied from 0.28 (RX) to 0.47 (DC) and from 0.22 (LFpen) to 0.75 (DC), respectively. At the D1 threshold, higher sensitivity and accuracy were found for LFpen (0.76/0.71) and ICDAS (0.65/0.66); and higher specificities were found for RX (0.94), DC (0.79), and ICDAS (0.71). At the D3 threshold, all methods exhibited lower sensitivities (0.13-0.35) and higher specificity, accuracy, and area under the ROC curve values (0.70-1.00). All methods showed a correlation with histological results, especially for ICDAS and DC. Conclusions: NILT technology (DC) and LFpen exhibited similar performance for the detection of occlusal caries lesions in deciduous molars when compared with ICDAS criteria.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Near-infrared light transillumination for occlusal caries detection in dog teeth: A comparative study
    Kolsuz, Mehmet Eray
    Ekim, Okan
    Irmak, Oezguer
    Evli, Cengiz
    Bakici, Caner
    Demirel, Guelbike
    ANKARA UNIVERSITESI VETERINER FAKULTESI DERGISI, 2024, 71 (01): : 27 - 30
  • [2] In vivo performance of near-infrared light transillumination for dentine proximal caries detection in permanent teeth
    Dundar, Ayse
    Ciftci, Mehmet Ertugul
    Isman, Ozlem
    Aktan, Ali Murat B.
    SAUDI DENTAL JOURNAL, 2020, 32 (04) : 187 - 193
  • [3] Validity of near-infrared light transillumination for the assessment of proximal caries in permanent teeth
    Wang, F.
    Su, C.
    Yang, C.
    von den Hoff, J. W.
    Bian, Z.
    Meng, L.
    AUSTRALIAN DENTAL JOURNAL, 2022, 67 (01) : 46 - 54
  • [4] Near-infrared transillumination with high dynamic range imaging for occlusal caries detection in vitro
    Litzenburger, Friederike
    Lederer, Alexander
    Kollmuss, Maximilian
    Hickel, Reinhard
    Kunzelmann, Karl-Heinz
    Heck, Katrin
    LASERS IN MEDICAL SCIENCE, 2020, 35 (09) : 2049 - 2058
  • [5] Caries detection and diagnostics with near-infrared light transillumination: Clinical experiences
    Soechtig, Friederike
    Hickel, Reinhard
    Kuehnisch, Jan
    QUINTESSENCE INTERNATIONAL, 2014, 45 (06): : 531 - 538
  • [6] Near-infrared transillumination with high dynamic range imaging for occlusal caries detection in vitro
    Friederike Litzenburger
    Alexander Lederer
    Maximilian Kollmuß
    Reinhard Hickel
    Karl-Heinz Kunzelmann
    Katrin Heck
    Lasers in Medical Science, 2020, 35 : 2049 - 2058
  • [7] Evaluation of occlusal caries detection and assessment by visual inspection, digital bitewing radiography and near-infrared light transillumination
    Schaefer, Gerrit
    Pitchika, Vinay
    Litzenburger, Friederike
    Hickel, Reinhard
    Kuehnisch, Jan
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (07) : 2431 - 2438
  • [8] Evaluation of occlusal caries detection and assessment by visual inspection, digital bitewing radiography and near-infrared light transillumination
    Gerrit Schaefer
    Vinay Pitchika
    Friederike Litzenburger
    Reinhard Hickel
    Jan Kühnisch
    Clinical Oral Investigations, 2018, 22 : 2431 - 2438
  • [9] Assessment of Near-Infrared (780nm) Light Transillumination Accuracy for Detection of Incipient Caries Lesions
    Topoliceanu, Claudiu
    Ghiorghe, Cristina-Angela
    Toma, Vasilica
    Andrian, Sorin
    Iovan, Gianina
    Stoleriu, Simona
    Pancu, Galina
    Nica, Irina
    Salceanu, Mihaela
    REVISTA DE CHIMIE, 2019, 70 (04): : 1333 - 1336
  • [10] In vivo validation of near-infrared light transillumination for interproximal dentin caries detection
    Jan Kühnisch
    Friederike Söchtig
    Vinay Pitchika
    Rüdiger Laubender
    Klaus W. Neuhaus
    Adrian Lussi
    Reinhard Hickel
    Clinical Oral Investigations, 2016, 20 : 821 - 829