Reliability of the Modified Ashworth Scale After Stroke for 13 Muscle Groups

被引:6
|
作者
Vidmar, Tjasa [1 ]
Kregar, Nika Goljar [1 ]
Puh, Urska [2 ,3 ,4 ]
机构
[1] Univ Rehabil Inst, Dept Rehabil Patients Stroke, Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Hlth Sci, Dept Physiotherapy, Ljubljana, Slovenia
[3] Univ Rehabil Inst, Res & Dev Unit, Ljubljana, Slovenia
[4] Univ Rehabil Inst, Res & Dev Unit, Linhartova 51, Ljubljana 1000, Slovenia
来源
关键词
Modified Ashworth Scale; Muscle tone; Rehabilitation; Reliability; Stroke; INTRA-RATER RELIABILITY; MODIFIED TARDIEU SCALE; INTERRATER RELIABILITY; SPASTICITY; LIMB; TONE;
D O I
10.1016/j.apmr.2023.04.008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To evaluate the reliability of the protocol for administration of the Modified Ashworth Scale (MAS) for all commonly affected muscle groups after stroke. Design: A repeated-measures design was used in administration of MAS for 13 muscle groups on 2 assessment days. Intrarater reliability and interrater reliability (between 3 raters) was assessed. Participants: 30 patients, 1-19 months after stroke (age 55.1 +/- 13.5 years; N=30). Main Outcome Measure: Intra- and interrater reliability of the muscle tone assessment protocol with MAS for 7 upper and 6 lower limb muscle groups compiled from previous studies; 1 modified and 4 originally described. The weighted kappa was calculated. Results: The most and the least frequently assigned MAS grades were 0 and 4, respectively. Agreement was the highest for grade 0 (49% within raters, 32% between raters). Intrarater reliability was good to excellent for upper limb (k=0.71-0.94) and moderate to excellent for lower limb (k=0.55-0.97) muscles. Interrater reliability was poor to good for upper limb (k=0.25-0.66) and moderate for lower limb (k=0.41-0.54) muscles. Conclusions: The intrarater reliability of MAS was moderate for the hip flexors. The reliability results for the other 4 muscles studied anew after stroke were similar to the predetermined ones. The better intrarater reliability results confirmed previous findings. Because of the low interrater reliability, caution is needed in interpreting the results when reassessment is not possible by the same examiner. A well-described protocol for administering the MAS may lead to its standardization. (c) 2023 by the American Congress of Rehabilitation Medicine.
引用
收藏
页码:1606 / 1611
页数:6
相关论文
共 50 条
  • [1] Is It Time to Go Beyond the Modified Ashworth Scale? Letter to the Editor on "Reliability of the Modified Ashworth Scale After Stroke for 13 Muscle Groups"
    Piscitelli, Daniele
    Pellicciari, Leonardo
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2023, 104 (10): : 1735 - 1736
  • [2] INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY
    BOHANNON, RW
    SMITH, MB
    [J]. PHYSICAL THERAPY, 1987, 67 (02): : 206 - 207
  • [3] Reliability of measurements obtained with the Modified Ashworth Scale in the lower extremities of people with stroke
    Blackburn, M
    van Vliet, P
    Mockett, SP
    [J]. PHYSICAL THERAPY, 2002, 82 (01): : 25 - 34
  • [4] Measurement of lower-limb muscle spasticity: Intrarater reliability of Modified Modified Ashworth Scale
    Ghotbi, Nastaran
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Hasson, Scott
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2011, 48 (01): : 83 - 88
  • [5] Test-retest reliability and inter-rater reliability of the Modified Tardieu Scale and the Modified Ashworth Scale in hemiplegic patients with stroke
    Li, F.
    Wu, Y.
    Li, X.
    [J]. EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2014, 50 (01) : 9 - 15
  • [6] Inter-rater reliability of the Modified Modified Ashworth Scale in assessing lower limb muscle spasticity
    Ghotbi, Nastaran
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Hasson, Scott
    Jamshidpour, Boushra
    Amiri, Somayeh
    [J]. BRAIN INJURY, 2009, 23 (10) : 815 - 819
  • [7] The interrater and intrarater reliability of the Modified Ashworth Scale in the assessment of muscle spasticity: Limb and muscle group effect
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Arab, Tahereh Khosravian
    Jalaie, Shohreh
    [J]. NEUROREHABILITATION, 2008, 23 (03) : 231 - 237
  • [8] Inter-rater reliability of the Modified Ashworth Scale and modified Modified Ashworth Scale in assessing poststroke elbow flexor spasticity
    Kaya, Taciser
    Karatepe, Altinay Goksel
    Gunaydin, Rezzan
    Koc, Aysegul
    Ercan, Ulku Altundal
    [J]. INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2011, 34 (01) : 59 - 64
  • [9] Reliability of the Modified Ashworth Scale and Modified Tardieu Scale in patients with spinal cord injuries
    P Akpinar
    A Atici
    F U Ozkan
    I Aktas
    D G Kulcu
    A Sarı
    B Durmus
    [J]. Spinal Cord, 2017, 55 : 944 - 949
  • [10] Reliability of the Modified Ashworth Scale and Modified Tardieu Scale in patients with spinal cord injuries
    Akpinar, P.
    Atici, A.
    Ozkan, F. U.
    Aktas, I.
    D, G. Kulcu
    Sari, A.
    Durmus, B.
    [J]. SPINAL CORD, 2017, 55 (10) : 944 - 949