Real-World Effectiveness of Portable Air Cleaners in Reducing Home Particulate Matter Concentrations

被引:1
|
作者
Lu, Frederic T. [1 ,5 ]
Laumbach, Robert J. [1 ,3 ]
Legard, Alicia [1 ]
Myers, Nirmala T. [1 ,2 ,6 ]
Black, Kathleen G. [1 ]
Ohman-Strickland, Pamela [1 ,4 ]
Alimokhtari, Shahnaz [1 ]
de Resende, Adriana [1 ]
Calderon, Leonardo [1 ,2 ]
Mainelis, Gediminas [1 ,2 ]
Kipen, Howard M. [1 ,3 ]
机构
[1] Rutgers State Univ, Environm & Occupat Hlth Sci Inst, Piscataway, NJ 08901 USA
[2] Rutgers State Univ, Sch Environm & Biol Sci, Dept Environm Sci, New Brunswick, NJ 08901 USA
[3] Rutgers State Univ, Sch Publ Hlth, Dept Environm & Occupat Hlth & Justice, Piscataway, NJ USA
[4] Rutgers State Univ, Sch Publ Hlth, Dept Biostat & Epidemiol, Piscataway, NJ USA
[5] US Dept Vet Affairs, War Related Illness & Injury Study Ctr, East Orange, NJ USA
[6] CDC NIOSH, Resp Hlth Div, Morgantown, WV USA
关键词
Particulate matter; Portable air cleaner; Filtration effectiveness; Indoor air; Naturalistic study; POLLUTION EXPOSURES; FILTRATION; HEALTH; IMPACT; QUALITY;
D O I
10.4209/aaqr.230202
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Portable air cleaners (PACs) equipped with HEPA filters are gaining attention as cost-effective means of decreasing indoor particulate matter (PM) air pollutants and airborne viruses. However, the performance of PACs in naturalistic settings and spaces beyond the room containing the PAC is not well characterized. We conducted a single-blinded randomized cross-over interventional study between November 2020 and May 2021 in the homes of adults who tested positive for COVID-19. The intervention was air filtration with PAC operated with the HEPA filter set installed ("filter" condition) versus removed ("sham" condition, i.e., control). Sampling was performed in 29 homes for two consecutive 24-hour periods in the primary room (containing the PAC) and a secondary room. PAC effectiveness, calculated as reductions in overall mean PM2.5 and PM10 concentrations during the filter condition, were for the primary rooms 78.8% and 63.9% (n = 23), respectively, and for the secondary rooms 57.9% and 60.4% (n = 22), respectively. When a central air handler (CAH) was reported to be in use, filter-associated reductions of PM were statistically significant during the day (06:00-22:00) and night (22:01-05:59) in the primary rooms but only during the day in the secondary rooms. Our study adds to the literature evaluating the real-world effects of PACs on a secondary room and considering the impact of central air systems on PAC performance.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Real-world Effectiveness of Portable Air Cleaners in Reducing Home Particulate Matter Concentrations
    Lu, F. T.
    Laumbach, R. J.
    Legard, A.
    Myers, N. T.
    Black, K. G.
    Ohman-Strickland, P. A.
    De Resende, A.
    Calderon, L. D.
    Mainelis, G.
    Kipen, H. M.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [2] A review on reducing indoor particulate matter concentrations from personal-level air filtration intervention under real-world exposure situations
    Zhu, Yutong
    Song, Xiaoming
    Wu, Rongshan
    Fang, Jiakun
    Liu, Lingyan
    Wang, Tong
    Liu, Shuo
    Xu, Hongbing
    Huang, Wei
    [J]. INDOOR AIR, 2021, 31 (06) : 1707 - 1721
  • [3] Assessing the effectiveness of portable HEPA air cleaners for reducing particulate matter exposure in King County, Washington homeless shelters: Implications for community congregate settings
    Huang, Ching-Hsuan
    Bui, Thu
    Hwang, Daniel
    Shirai, Jeffry
    Austin, Elena
    Cohen, Martin
    Gould, Timothy
    Larson, Timothy
    Novosselov, Igor
    Tan, Shirlee
    Fox, Julie
    Seto, Edmund
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 891
  • [4] Portable air cleaners and residential exposure to SARS-CoV-2 aerosols: A real-world study
    Myers, Nirmala T.
    Laumbach, Robert J.
    Black, Kathleen G.
    Ohman-Strickland, Pamela
    Alimokhtari, Shahnaz
    Legard, Alicia
    De Resende, Adriana
    Calderon, Leonardo
    Lu, Frederic T.
    Mainelis, Gediminas
    Kipen, Howard M.
    [J]. INDOOR AIR, 2022, 32 (04)
  • [5] The Impact of Real-World Particulate Matter Air Pollution on the Airways of Susceptible Individuals
    Pfeffer, Paul E.
    Mudway, Ian S.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 198 (11) : 1362 - 1363
  • [6] Effects of portable air cleaners and A/C unit fans on classroom concentrations of particulate matter in a non-urban elementary school
    Azevedo, Alexandra
    Liddie, Jahred
    Liu, Jason
    Schiff, Jessica E.
    Adamkiewicz, Gary
    Hart, Jaime E.
    [J]. PLOS ONE, 2022, 17 (12):
  • [7] Effectiveness of portable HEPA air cleaners on reducing indoor endotoxin, PM10, and coarse particulate matter in an agricultural cohort of children with asthma: A randomized intervention trial
    Riederer, Anne M.
    Krenz, Jennifer E.
    Tchong-French, Maria I.
    Torres, Elizabeth
    Perez, Adriana
    Younglove, Lisa R.
    Jansen, Karen L.
    Hardie, David C.
    Farquhar, Stephanie A.
    Sampson, Paul D.
    Metwali, Nervana
    Thorne, Peter S.
    Karr, Catherine J.
    [J]. INDOOR AIR, 2021, 31 (06) : 1926 - 1939
  • [8] Reduced Fine Particulate Matter Air Pollution Exposures Using In-Home Portable Air Cleaners PILOT RESULTS OF THE CARDIAC REHABILITATION AIR FILTER TRIAL (CRAFT)
    Bard, Robert L.
    Rubenfire, Melvyn
    Fink, Samantha
    Bryant, Joseph
    Wang, Lu
    Speth, Kelly
    Zhou, Nina
    Morishita, Masako
    Brook, Robert D.
    [J]. JOURNAL OF CARDIOPULMONARY REHABILITATION AND PREVENTION, 2020, 40 (04) : 276 - 279
  • [9] EFFECTIVENESS OF PORTABLE INDOOR AIR CLEANERS - SENSORY TESTING RESULTS
    SHAUGHNESSY, RJ
    LEVETIN, E
    BLOCKER, J
    SUBLETTE, KL
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (03): : 179 - 188
  • [10] Effects of air cleaners and school characteristics on classroom concentrations of particulate matter in 34 elementary schools in Korea
    Park, Ju-Hyeong
    Lee, Tae Jung
    Park, Mi Jeong
    Oh, Hyungna
    Jo, Young Min
    [J]. BUILDING AND ENVIRONMENT, 2020, 167