Experimental assessment of concrete masonry units integrated with insulation and phase change material: A wall-pattern study

被引:7
|
作者
Zhang, Yuan [1 ,3 ,4 ]
Sun, Xiaoqin [2 ,3 ]
Medina, Mario A. [3 ]
机构
[1] Yangzhou Univ, Coll Architectural Sci & Engn, Yangzhou, Jiangsu, Peoples R China
[2] Changsha Univ Sci & Technol, Sch Energy & Power Engn, Changsha, Hunan, Peoples R China
[3] Univ Kansas, Dept Civil Environm & Architectural Engn, Lawrence, KS USA
[4] Yangzhou Univ, Coll Architectural Sci & Engn, Yangzhou 225127, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal insulation material; Phase change material; Concrete masonry unit; Multi-layer unit; Stationary thermal performance; Transient thermal performance; CHANGE MATERIALS (PCMS)-BRICKS; CHANGE MATERIALS PCM; THERMAL PERFORMANCE; HOLLOW BRICKS; BUILDING WALLS; CLAY BRICKS; CONFIGURATION; IMPACT; OPTIMIZATION; LOCATION;
D O I
10.1016/j.energy.2023.130038
中图分类号
O414.1 [热力学];
学科分类号
摘要
The installation of functional materials, including thermal insulation materials (TIMs) and phase change materials (PCMs), in concrete masonry unit (CMU) block (brick) walls is expected to obtain high thermal performance. However, since the apparent thermal capacity of PCMs is affected by a variety of factors, how to use PCMs rationally becomes a complex and systematic issue. At the same time, how to combine PCMs with TIMs in building envelope to achieve high stationary and transient thermal performances simultaneously is also an important issue that arises with the application of PCMs. The quantitative impact of the key factors, including the underlying patterns of the functional materials themselves, as well as others such as wall pattern, the location, quantity, and handling of the functional materials, is still not clear. In this study, a wall pattern analysis is experimentally performed for the integration of TIM and PCM in CMU-block walls. Walls equipped with various volumes of the two functional materials in eight placement modes under three representative thermal conditions are measured and discussed. The performance associated with the wall modes is completely analyzed. Thermal bridging is found to be a key factor in weakening the effect of the functional materials filled in wall cavities. In addition, the optimal locations and volumes of the functional materials are obtained. This study thermally reveals and gathers effect laws and applied principles, and provides data reference for the proper use of TIM and PCM outfitted building envelopes.
引用
收藏
页数:28
相关论文
共 50 条
  • [1] Thermal performance of concrete masonry units containing insulation and phase change material
    Zhang, Yuan
    Sun, Xiaoqin
    Medina, Mario A.
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [2] Experimental assessment of a phase change material for wall building use
    Kuznik, Frederic
    Virgone, Joseph
    APPLIED ENERGY, 2009, 86 (10) : 2038 - 2046
  • [3] AN EXPERIMENTAL STUDY OF SHAPE-STABILIZED PHASE CHANGE MATERIAL USED IN THE PHASE CHANGE MATERIAL WALL
    Zhang, Lin
    Yan, Quanying
    Liang, Chen
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 577 - 583
  • [4] Study on thermal performance of dynamic insulation roof integrated with phase change material
    Yu, Jinghua
    Yang, Hongyun
    Zhao, Jingang
    Zhang, Chong
    Qian, Congcong
    Chen, Yanhua
    Tang, Xiaoliang
    ENERGY AND BUILDINGS, 2024, 303
  • [5] Flammability assessment of phase change material wall lining and insulation materials with different weight fractions
    McLaggan, Martyn S.
    Hadden, Rory M.
    Gillie, Martin
    ENERGY AND BUILDINGS, 2017, 153 : 439 - 447
  • [6] Enhancing building wall thermal performance with phase change material and insulation: A comparative and synergistic assessment
    Tuncbilek, Ekrem
    Arici, Muslum
    Krajcik, Michal
    Li, Dong
    Nizetic, Sandro
    Papadopoulos, Agis M.
    RENEWABLE ENERGY, 2023, 218
  • [7] Experimental study of a personal cooling system integrated with phase change material
    Qiao, Yiyuan
    Cao, Tao
    Muehlbauer, Jan
    Hwang, Yunho
    Radermacher, Reinhard
    APPLIED THERMAL ENGINEERING, 2020, 170
  • [8] An Experimental Study On Solar Water Heater Integrated With Phase Change Material
    Rathore, Pushpendra Kumar Singh
    ADVANCES IN FLUID AND THERMAL ENGINEERING, 2019, : 347 - 356
  • [9] Experimental Study on Effect of Concrete Frame Ratio on Thermal Performance of Structural Insulation Integrated Wall Panels
    Xiong, Feng
    Lou, Guangya
    Ran, Mingming
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2025, 52 (01): : 69 - 83
  • [10] Research on the thermal performance of the phase change material concrete wall
    Yan, Q. (yanquanying@bucea.edu.cn), 2012, Science Press (33):