Physiological responses of plants to in vivo X-ray damage from X-ray fluorescence measurements: insights from anatomical, elemental, histochemical, and ultrastructural analyses

被引:4
|
作者
Montanha, Gabriel Sgarbiero [1 ,2 ]
Marques, Joao Paulo Rodrigues [3 ]
Santos, Eduardo [1 ]
Jones, Michael W. M. [4 ]
de Carvalho, Hudson Wallace Pereira [1 ,5 ]
机构
[1] Univ Sao Paulo, Ctr Nucl Energy Agr, Lab Nucl Instrumentat, Piracicaba, Brazil
[2] Sapienza Univ Rome, Biol & Biotechnol Dept Charles Darwin, Rome, Italy
[3] Univ Sao Paulo, Fac Anim Sci & Food Engn, Dept Basic Sci, Pirassununga, Brazil
[4] Queensland Univ Technol, Sch Chem & Phys, Cent Analyt Res Facil, Brisbane, Australia
[5] Univ Sao Paulo, Ctr Nucl Energy Agr, Lab Nucl Instrumentat, BR-13400970 Piracicaba, Brazil
基金
巴西圣保罗研究基金会;
关键词
soybean (Glycine max); X-ray fluorescence spectroscopy; radiation damage; plant anatomy; RADIATION-DOSE LIMITS; SPECIATION; CALCIUM; PROBE;
D O I
10.1093/mtomcs/mfad034
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
X-ray fluorescence spectroscopy (XRF) is a powerful technique for the in vivo assessment of plant tissues. However, the potential X-ray exposure damages might affect the structure and elemental composition of living plant tissues, leading to artefacts in the recorded data. Herein, we exposed in vivo soybean (Glycine max (L.) Merrill) leaves to several X-ray doses through a polychromatic benchtop microprobe X-ray fluorescence spectrometer, modulating the photon flux density by adjusting either the beam size, current, or exposure time. Changes in the irradiated plant tissues' structure, ultrastructure, and physiology were investigated through light and transmission electron microscopy (TEM). Depending on X-ray exposure dose, decreased K and X-ray scattering intensities and increased Ca, P, and Mn signals on soybean leaves were recorded. Anatomical analysis indicated the necrosis of epidermal and mesophyll cells on the irradiated spots, where TEM images revealed the collapse of cytoplasm and cell wall breaking. Furthermore, the histochemical analysis detected the production of reactive oxygen species and the inhibition of chlorophyll autofluorescence in these areas. Under certain X-ray exposure conditions, e.g. high photon flux density and long exposure time, XRF measurements may affect the soybean leaves structures, elemental composition, and cellular ultrastructure, inducing programmed cell death. Our characterization shed light on the plant's responses to the X-ray-induced radiation damage and might help to establish proper X-ray radiation limits and novel strategies for in vivo benchtop-XRF analysis of vegetal materials.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Elemental Analysis of Aquatic Plants by X-ray Fluorescence
    Chuparina, Elena V.
    Azovsky, Minzafar G.
    ANALYTICAL LETTERS, 2016, 49 (12) : 1963 - 1973
  • [2] A new micro X-ray fluorescence spectrometer for in vivo elemental analysis in plants
    Fittschen, U. E. A.
    Kunz, H. -H.
    Hohner, R.
    Tyssebotn, I. M. B.
    Fittschen, A.
    X-RAY SPECTROMETRY, 2017, 46 (05) : 374 - 381
  • [3] X-RAY DAMAGE OF THE FACE FROM COSMETIC X-RAY EPILATION
    FERGUSON, EH
    GRIEM, SF
    ARCHIVES OF DERMATOLOGY, 1956, 73 (04) : 406 - 406
  • [4] Feasibility of a fluorescent X-ray source for in vivo X-ray fluorescence measurements of kidney and liver cadmium
    Börjesson, J
    Olsson, M
    Mattsson, S
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 255 - 258
  • [5] The Radio/X-Ray Correlation in X-Ray Binaries-Insights from a Hard X-Ray Perspective
    Koljonen, Karri I. I.
    Russell, David M.
    ASTROPHYSICAL JOURNAL, 2019, 871 (01):
  • [6] A Low Energy X-Ray Fluorescence Spectrometer for Elemental Mapping X-Ray Microscopy
    Alberti, R.
    Longoni, A.
    Klatka, T.
    Guazzoni, C.
    Gianoncelli, A.
    Bacescu, D.
    Kaulich, B.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 839 - +
  • [7] X-ray scattering and x-ray fluorescence from materials with rough interfaces
    deBoer, DKG
    PHYSICAL REVIEW B, 1996, 53 (10): : 6048 - 6064
  • [8] X-ray scattering and x-ray fluorescence from materials with rough interfaces
    De, Boer, D. K. G.
    Physical Review B: Condensed Matter, 53 (10):
  • [9] A laboratory X-ray microbeam for combined X-ray diffraction and fluorescence measurements
    Rouziere, S.
    Jourdanneau, E.
    Kasmi, B.
    Joly, P.
    Petermann, D.
    Albouy, P. A.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2010, 43 : 1131 - 1133
  • [10] From papyrus to paper: Elemental characterization by X-ray fluorescence spectrometry
    Manso, M.
    Costa, M.
    Carvalho, M. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 732 - 734