Automatic segmentation of esophageal gross tumor volume in 18F-FDG PET/CT images via GloD-LoATUNet

被引:5
|
作者
Yue, Yaoting [1 ,2 ]
Li, Nan [3 ]
Zhang, Gaobo [1 ]
Zhu, Zhibin [4 ]
Liu, Xin [5 ]
Song, Shaoli [3 ]
Ta, Dean [1 ,5 ]
机构
[1] Fudan Univ, Ctr Biomed Engn, Sch Informat Sci & Technol, Shanghai 200438, Peoples R China
[2] Fudan Univ, Human Phenome Inst, Shanghai 201203, Peoples R China
[3] Fudan Univ, Dept Nucl Med, Shanghai Canc Ctr, Shanghai 201321, Peoples R China
[4] Hexi Univ, Sch Phys & Electromech Engn, Zhangye 734000, Gansu, Peoples R China
[5] Fudan Univ, Acad Engn & Technol, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
Esophageal gross tumor volume; Segmentation; Transformer; PET; CT; SEMANTIC SEGMENTATION; ATTENTION; TRANSFORMER; CT;
D O I
10.1016/j.cmpb.2022.107266
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: For esophageal squamous cell carcinoma, radiotherapy is one of the primary treatments. During the planning before radiotherapy, the intractable task is to precisely delineate the esophageal gross tumor volume (GTV) on medical images. In current clinical practice, the manual delineation suffers from high intra- and inter-rater variability, while also exhausting the oncologists on a treadmill. There is an urgent demand for effective com puter-aided automatic segmentationmethods. To this end, we designed a novel deep network, dubbed as GloD-LoATUNet. Methods: GloD-LoATUNet follows the effective U-shape structure. On the contractile path, the global deformable dense attention transformer (GloDAT), local attention transformer (LoAT), and convolution blocks are integrated to model long-range dependencies and localized information. On the center bridge and the expanding path, convolution blocks are adopted to upsample the extracted representations for pixel-wise semantic prediction. Between the peer-to-peer counterparts, enhanced skip connections are built to compensate for the lost spatial information and dependencies. By exploiting complementary strengths of the GloDAT, LoAT, and convolution, GloD-LoATUNet has remarkable representation learning capabilities, performing well in the prediction of the small and variable esophageal GTV.Results: The proposed approach was validated in the clinical positron emission tomography/computed tomography (PET/CT) cohort. For 4 different data partitions, we report the Dice similarity coefficient (DSC), Hausdorff distance (HD), and Mean surface distance (MSD) as: 0.83 +/- 0.13, 4.88 +/- 9.16 mm , and 1.40 +/- 4.11 mm ; 0.84 +/- 0.12, 6.89 +/- 12.04 mm , and 1.18 +/- 3.02 mm ; 0.84 +/- 0.13, 3.89 +/- 7.64 mm , and 1.28 +/- 3.68 mm ; 0.86 +/- 0.09, 3.71 +/- 4.79 mm , and 0.90 +/- 0.37 mm ; respectively. The predicted contours present a desirable consistency with the ground truth.Conclusions: The inspiring results confirm the accuracy and generalizability of the proposed model, demonstrating the potential for automatic segmentation of esophageal GTV in clinical practice.(c) 2022 Published by Elsevier B.V.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A Dirichlet process mixture model for automatic segmentation of 18F-FDG PET-CT images
    Giri, M. G.
    Cavedon, C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S508 - S509
  • [2] Is Automatic Tumor Segmentation on Whole-Body 18F-FDG PET Images a Clinical Reality?
    Sundar, Lalith Kumar Shiyam
    Beyer, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65 (07) : 995 - 997
  • [3] 18F-FDG PET and 18F-FDG PET/CT for Assessing Response to Therapy in Esophageal Cancer
    Krause, Bernd J.
    Herrmann, Ken
    Wieder, Hinrich
    zum Bueschenfelde, Christian Meyer
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 : 89S - 96S
  • [4] Automated Esophageal Gross Tumor Volume Segmentation in 18F-FDG PET and CT for Radiotherapy using Two-Stream 3D Deep Network Fusion
    Ho, Tsung-Ying
    Jin, Dakai
    Guo, Dazhou
    Tseng, Chen-Kan
    Xiao, Jing
    Lu, Le
    Yen, Tzu-Chen
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [5] Prognostic Value of Metabolic Tumor Volume Measured by 18F-FDG PET/CT in Esophageal Cancer Patients
    Soydal, C.
    Yuksel, C.
    Kucuk, O. N.
    Okten, I.
    Ozkan, E.
    Erdogan, B. Doganay
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S363 - S363
  • [6] Optimisation of automatic image segmentation for tumour volume determination in 18F-FDG PET/CT for patients with liver lesions
    Ruiz, D.
    Kalogianni, E.
    Corcoran, B.
    Eccles, A.
    Mulholland, N.
    Vivian, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S377 - S377
  • [7] Primary Hepatic Gastrointestinal Stromal Tumor on 18F-FDG PET/CT Images
    Jiang, Yang
    Lu, Qingqing
    Lou, Cen
    Huang, Zhongke
    CLINICAL NUCLEAR MEDICINE, 2023, 48 (08) : 722 - 724
  • [8] Implementation and optimization of automatic 18F-FDG PET segmentation Methods
    Berthon, B.
    Marshall, C.
    Evans, M.
    Spezi, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S299 - S299
  • [9] Volumetric Evaluation of Staging 18F-FDG PET/CT Images in Patients with Esophageal Cancer
    Sen, Nazli Pinar Karahan
    Aksu, Aysegul
    Kaya, Gamze Capa
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2022, 31 (03) : 216 - 222
  • [10] Variability of Gross Tumor Volume in Nasopharyngeal Carcinoma Using 11C-Choline and 18F-FDG PET/CT
    Jiang, Jun
    Wu, Hubing
    Huang, Meiyan
    Wu, Yao
    Wang, Quanshi
    Zhao, Jianqi
    Yang, Wei
    Chen, Wufan
    Feng, Qianjin
    PLOS ONE, 2015, 10 (07):