Concordance between alizarin red stained skeleton and micro-CT skeleton evaluation methods: A case study in New Zealand White rabbits

被引:0
|
作者
Solomon, Howard M. [1 ]
Murzyn, Stacia [1 ]
Rendemonti, Joyce [1 ]
Chapman, Sharon [1 ]
Cheng, Shih-Hsun [2 ]
Jucker, Beat M. [2 ]
Stanislaus, Dinesh [1 ]
Gehman, Andrew [3 ]
Alsaid, Hasan [2 ,4 ]
机构
[1] GSK, IVIVT, Reprod Toxicol, Collegeville, PA USA
[2] GSK, Bioimaging, IVIVT, Collegeville, PA USA
[3] GSK, Res & MDS Stat, Collegeville, PA USA
[4] GSK, IVIVT, Bioimaging, 1250 S Collegeville Rd, Collegeville, PA 19426 USA
来源
BIRTH DEFECTS RESEARCH | 2023年 / 115卷 / 14期
关键词
alizarin red stained; embryo fetal development; fetal skeletal abnormalities; micro-CT; skeletal concordance;
D O I
10.1002/bdr2.2179
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives: The objective of this study was to examine the fetal skeletons using both alizarin red stain and micro-computed tomography (CT) images; investigate differences, and to determine if the conclusions of the study were the same regardless of the examination method.Methods: A candidate drug was given orally by gavage to pregnant New Zealand White rabbits on gestation day (GD) 7 to GD 19 (mating = GD 0) at doses of 0 (control), 0.02, 0.5, 5, and 15 mg/kg/day. Maternal toxicity was evident at =0.02 mg/kg/day. The 199 fetal skeletons (totaling 50,546 skeletal elements) obtained at cesarean delivery on GD29 were first stained with Alizarin Red S, then imaged by a Siemens Inveon micro-CT scanner. All fetal skeletons were examined by both methods, without knowledge of dose group, and the results were compared.Results: In total, 33 types of skeletal abnormalities were identified. There was 99.8% concordance of results comparing stain to micro-CT. Ossification of the middle phalanx of the forepaw digit 5 showed the greatest difference between the two methods.Conclusion: Overall, micro-CT imaging is a realistic, and robust alternative to skeletal staining to examine fetal rabbit skeletons in developmental toxicity studies.
引用
收藏
页码:1284 / 1293
页数:10
相关论文
共 4 条
  • [1] Micro-CT Evaluation of Alizarin Red S Stained Mouse, Rat and Rabbit Fetuses
    Ying, X.
    Ji, J.
    Barlow, N.
    Oswald, J.
    Feuston, M.
    BIRTH DEFECTS RESEARCH PART A-CLINICAL AND MOLECULAR TERATOLOGY, 2010, 88 (05) : 383 - 383
  • [2] The use of micro-CT imaging to examine and illustrate fetal skeletal abnormalities in Dutch Belted rabbits and to prove concordance with Alizarin Red stained skeletal examination
    Solomon, Howard M.
    Murzyn, Stacia
    Rendemonti, Joyce
    Chapman, Sharon
    Skedzielewski, Tinamarie
    Jucker, Beat M.
    Stanislaus, Dinesh
    Alsaid, Hasan
    BIRTH DEFECTS RESEARCH, 2018, 110 (03): : 276 - 298
  • [3] Application of micro-CT Imaging in a Preliminary Embryo-Fetal Development Study in New Zealand White Rabbits
    Solomon, H. M.
    Murzyn, S.
    Rendemonti, J. E.
    Chapman, S. P.
    Junker, B. M.
    Stanislaus, D. J.
    Alsaid, H.
    BIRTH DEFECTS RESEARCH, 2019, 111 (09): : 515 - 515
  • [4] Micro-CT evaluation of bone grow concept of an implant with microstructured backtaper crestally and sub-crestally placed. Preliminary study in New Zealand rabbits tibia at one month
    Calvo-Guirado, Jose Luis
    Cabo-Pastor, Marta Belen
    de Carlos-Villafranca, Felix
    Garcia-Carrillo, Nuria
    Fernandez-Dominguez, Manuel
    Martinez, Francisco Martinez
    AIMS BIOENGINEERING, 2023, 10 (04): : 406 - 420