Association of ambient PM10 and PM2.5 with coronary stenosis measured using selective coronary angiography

被引:3
|
作者
Luo, Manqing [1 ,2 ,3 ]
Xie, Xiaowei [4 ]
Wu, Jieyu [5 ]
Zhang, Liwei [1 ,2 ,3 ]
Zheng, Xi [1 ,2 ,3 ]
Xie, Mengying [6 ]
Lin, Na [1 ,2 ,3 ]
Xiao, Huazhen [1 ,2 ,3 ]
Zeng, Jilang [1 ,2 ,3 ]
Lan, Guohui [5 ]
Lu, Xiaoli [5 ]
Ye, Xiaoying [5 ]
Huang, Zelin [5 ]
Xu, Tingting [5 ]
Wang, Tinggui [5 ]
Lin, Kaiyang [1 ,2 ,3 ]
Guo, Yansong [1 ,2 ,3 ]
Xie, Xiaoxu [5 ,7 ]
机构
[1] Fujian Med Univ, Fujian Prov Hosp, Shengli Clin Med Coll, Dept Cardiol, Fuzhou, Peoples R China
[2] Fujian Prov Clin Res Ctr Severe Acute Cardiovasc D, Fujian Prov Ctr Geriatr, Fujian Prov Key Lab Cardiovasc Dis, Fuzhou, Peoples R China
[3] Fujian Heart Failure Ctr Alliance, Fuzhou, Peoples R China
[4] Shanxi Med Univ, Clin Med Sch 1, Taiyuan, Peoples R China
[5] Fujian Med Univ, Sch Publ Hlth, Dept Epidemiol & Hlth Stat, Fuzhou, Peoples R China
[6] Nanchang Univ, Clin Med Sch 2, Nanchang, Peoples R China
[7] Fujian Med Univ, Affiliated Hosp 2, Clin Res Unit, Quanzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Particulate matter; Atherosclerosis; Coronary stenosis; Epidemiology; Angiography; AIR-POLLUTION; CARDIOVASCULAR-DISEASES; RISK-FACTORS; EXPOSURE; ATHEROSCLEROSIS; HEMOGLOBIN;
D O I
10.1016/j.ecoenv.2023.115338
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: Long-term ambient particulate matter (PM) exposure exerts detrimental effects on cardiovascular health. Evidence on the relation of chronically exposed ambient PM10 and PM2.5 with coronary stenosis remains lacking. Our aim was to investigate the association of PM10 and PM2.5 with coronary stenosis in patients undergoing coronary angiography. Methods: We performed a retrospective cohort study consisting of 7513 individuals who underwent coronary angiography in Fujian Province, China, from January 2019 to December 2021. We calculated a modified Gensini score (GS) to represent the degree of stenosis in coronary arteries by selective coronary angiography. We fitted linear regressions and logistic models to assess the association of PM10 and PM2.5 with coronary stenosis. We employed restricted cubic splines to describe the exposure-response curves. We performed mediation analyses to assess the potential mediators. Results: Long-term ambient PM10 and PM2.5 (prior three years average) exposure was significantly associated with the GS, with a breakpoint concentration of 47.5 & mu;g/m3 and 25.8 & mu;g/m3 for PM10 and PM2.5, respectively, above which we found a linear positive exposure-response relationship of ambient PM with GS. Each 10 & mu;g /m3 increase in PM10 exposure (13: 4.81, 95 % CI: 0.44-9.19) and PM2.5 exposure [13: 10.50, 95 % CI: 3.14-17.86] were positively related to the GS. The adjusted odds ratio (OR) for each 10 & mu;g/m3 increment in PM10 exposure on severe coronary stenosis was 1.33 (95 % CI: 1.04-1.76). Correspondingly, the adjusted OR for PM2.5 was 1.87 (95 % CI: 1.24-2.99). The mediation analysis indicated that the effect of PM10 on coronary stenosis may be partially mediated through total cholesterol, low-density lipoprotein cholesterol, apolipoprotein B, serum creatinine and blood urea nitrogen, and the effect of PM2.5 may be mediated in part by hemoglobin A1c. Conclusion: Our study provides the first evidence that chronic ambient PM10 and PM2.5 exposure was associated with coronary stenosis assessed by GS in patients with suspected coronary artery disease and reveals its potential mediators.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] An evaluation of PM10 and PM2.5 size selective inlet performance using ambient aerosol
    Keywood, MD
    Ayers, GP
    Gras, JL
    Gillett, RW
    Cohen, D
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1999, 30 (04) : 401 - 407
  • [2] Assessment of ambient air PM10 and PM2.5 and characterization of PM10 in the city of Kanpur, India
    Sharma, M
    Maloo, S
    [J]. ATMOSPHERIC ENVIRONMENT, 2005, 39 (33) : 6015 - 6026
  • [3] Sources of PM10 and PM2.5 in Cairo’s ambient air
    M. Abu-Allaban
    D. H. Lowenthal
    A. W. Gertler
    M. Labib
    [J]. Environmental Monitoring and Assessment, 2007, 133 : 417 - 425
  • [4] Source apportionment of ambient PM10 and PM2.5 in Haikou, China
    Fang, Xiaozhen
    Bi, Xiaohui
    Xu, Hong
    Wu, Jianhui
    Zhang, Yufen
    Feng, Yinchang
    [J]. ATMOSPHERIC RESEARCH, 2017, 190 : 1 - 9
  • [5] Sources of PM10 and PM2.5 in Cairo's ambient air
    Abu-Allaban, M.
    Lowenthal, D. H.
    Gertler, A. W.
    Labib, M.
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2007, 133 (1-3) : 417 - 425
  • [6] Source apportionment of ambient PM10 and PM2.5 in Haikou, China
    Fang, Xiaozhen
    Bi, Xiaohui
    Xu, Hong
    Wu, Jianhui
    Zhang, Yufen
    Feng, Yinchang
    [J]. Atmospheric Research, 2017, 190 : 1 - 9
  • [7] Comparison of PM2.5 and PM10 monitors
    Williams, R
    Suggs, J
    Rodes, C
    Lawless, P
    Zweidinger, R
    Kwok, R
    Creason, J
    Sheldon, L
    [J]. JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2000, 10 (05): : 497 - 505
  • [8] Comparison of PM2.5 and PM10 monitors
    RON WILLIAMS
    JACK SUGGS
    CHARLES RODES
    PHIL LAWLESS
    ROY ZWEIDINGER
    RICHARD KWOK
    JOHN CREASON
    LINDA SHELDON
    [J]. Journal of Exposure Science & Environmental Epidemiology, 2000, 10 : 497 - 505
  • [9] PM10 and PM2.5:: an international perspective
    Sloss, LL
    Smith, IM
    [J]. FUEL PROCESSING TECHNOLOGY, 2000, 65 : 127 - 141
  • [10] Spatial and temporal variations in ambient PM2.5 and PM10 in Mexico City
    [J]. Villasenor, R., 1600, Elsevier Science Ltd, Exeter, United Kingdom (31):