Effect of the Application of Ultrasound to Homogenize Milk and the Subsequent Pasteurization by Pulsed Electric Field, High Hydrostatic Pressure, and Microwaves

被引:2
|
作者
Astrain-Redin, Leire [1 ]
Skipnes, Dagbjorn [2 ]
Cebrian, Guillermo [1 ]
Alvarez-Lanzarote, Ignacio [1 ]
Rode, Tone Mari [2 ]
机构
[1] Univ Zaragoza CITA, Fac Vet, Dept Prod Anim & Ciencia Alimentos, Tecnol Alimentos,Inst Agroalimentario Aragon IA2, Zaragoza 50013, Spain
[2] NOFIMA Norwegian Inst Food, Fisheries & Aquaculture Res, N-4021 Stavanger, Norway
关键词
milk; homogenization; novel technologies; pasteurization; FAT GLOBULES; WHOLE MILK; SKIM MILK; PHYSICOCHEMICAL PROPERTIES; BACTERIAL INACTIVATION; SHELF-LIFE; PARAMETERS; FOOD; TECHNOLOGY; STABILITY;
D O I
10.3390/foods12071457
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The efficacy of applying ultrasound (US) as a system to homogenize emulsions has been widely demonstrated. However, research has not yet shown whether the effect achieved by homogenizing milk with US is modified by subsequent pasteurization treatments that use new processing technologies such as pulsed electric fields (PEF), microwaves (MW), and high hydrostatic pressure (HPP). The aim of this study was, therefore, to optimize the application of US for milk homogenization and to evaluate the effect of PEF, HPP, and MW pasteurization treatments on the sensorial, rheological, and microbiological properties of milk throughout its shelf life. To homogenize whole milk, a continuous US system (20 kHz, 0.204 kJ/mL, 100%, 40 degrees C) was used, and different ultrasonic intensities (0.25, 0.5, and 1.0 kJ/mL) were evaluated. The optimal ultrasonic treatment was selected on the basis of fat globule size distribution and pasteurization treatments by MW (5800W, 1.8 L/min), PEF (120 kJ/kg, 20 kV/cm) and HPP (600 MPa, 2 min, 10 degrees C) was applied. The ultrasound intensity that achieved the highest reduction in fat globule size (0.22 +/- 0.02 mu m) and the most homogeneous distribution was 1.0 kJ/mL. Fat globule size was smaller than in commercial milk (82% of volume < 0.5 mu m for US milk versus 97% of volume < 1.2 mu m for commercial milk). That size was maintained after the application of the different pasteurization treatments, and the resulting milk had better emulsion stability than commercial milk. After 28 days of storage, no differences in viscosity (4.4-4.9 mPa s) were observed. HPP pasteurization had the greatest impact on color, leading to higher yellowness values than commercial milk. Microbial counts did not vary significantly after 28 days of storage, with counts below 10(2) CFU/mL for samples incubated at 15 degrees C and at 37 degrees C. In summary, the homogenization of milk obtained by US was not affected by subsequent pasteurization processes, regardless of the technology applied (MW, PEF, or HPP). Further research is needed to evaluate these procedures' effect on milk's nutritional and functional properties.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Effect of high hydrostatic pressure, ultrasound and pulsed electric fields on milk composition and characteristics
    Jelicic, Irena
    Lisak, Katarina
    Bozanic, Rajka
    [J]. MLJEKARSTVO, 2012, 62 (01): : 3 - 13
  • [2] Update on nonthermal food processing technologies:: Pulsed electric field, high hydrostatic pressure, irradiation and ultrasound
    Barbosa-Cánovas, GV
    Rodríguez, JJ
    [J]. FOOD AUSTRALIA, 2002, 54 (11): : 513 - 520
  • [3] Effect of high-hydrostatic pressure and moderate-intensity pulsed electric field on plum
    Garcia-Parra, J.
    Gonzalez-Cebrino, F.
    Delgado-Adamez, J.
    Cava, R.
    Martin-Belloso, O.
    Elez-Martinez, P.
    Ramirez, R.
    [J]. FOOD SCIENCE AND TECHNOLOGY INTERNATIONAL, 2018, 24 (02) : 145 - 160
  • [4] Implications of Pulsed Electric Field Pre-Treatment on Goat Milk Pasteurization
    Araujo, Alberta
    Barbosa, Carla
    Alves, Manuel Rui
    Romao, Alexandre
    Fernandes, Paulo
    [J]. FOODS, 2023, 12 (21)
  • [5] High Voltage Pulse Generator for Pulsed Electric Field Pasteurization
    Garcia Rocher, Edgar
    Alejos Palomares, Ruben
    Banuelos Sanchez, Pedro
    [J]. 20TH INTERNATIONAL CONFERENCE ON ELECTRONICS COMMUNICATIONS AND COMPUTERS (CONIELECOMP 2010), 2010, : 276 - 280
  • [6] Comparison of the Effects of High Hydrostatic Pressure and Pasteurization on Quality of Milk during Storage
    Yu, Tongtong
    Zhang, Xiaojun
    Feng, Ruoyi
    Wang, Caiyun
    Wang, Xiaoyu
    Wang, Yongtao
    [J]. FOODS, 2022, 11 (18)
  • [7] Impact of pulsed electric fields, high hydrostatic pressure, and thermal pasteurization on selected characteristics of Opuntia dillenii cactus juice
    Moussa-Ayoub, Tamer E.
    Jaeger, Henry
    Knorr, Dietrich
    El-Samahy, Salah K.
    Kroh, Lothar W.
    Rohn, Sascha
    [J]. LWT-FOOD SCIENCE AND TECHNOLOGY, 2017, 79 : 534 - 542
  • [8] Effect of high hydrostatic pressure (HPP) and pulsed electric field (PEF) technologies on reduction of aflatoxins in fruit juices
    Pallares, Noelia
    Berrada, Houda
    Tolosa, Josefa
    Ferrer, Emilia
    [J]. LWT-FOOD SCIENCE AND TECHNOLOGY, 2021, 142
  • [9] Identification of equivalent processing conditions for pasteurization of strawberry juice by high pressure, ultrasound, and pulsed electric fields processing
    Yildiz, Semanur
    Pokhrel, Prashant Raj
    Unluturk, Sevcan
    Barbosa-Canovas, Gustavo, V
    [J]. INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2019, 57
  • [10] Design and Fabrication Pasteurization of Fresh Milk-based on Pulsed Electric Field Technology
    Manurung, Robeth Viktoria
    Sulaeman, Yaya
    Kurniadi, Deni Permana
    Suharto, Budhi
    [J]. 2021 INTERNATIONAL CONFERENCE ON RADAR, ANTENNA, MICROWAVE, ELECTRONICS, AND TELECOMMUNICATIONS (ICRAMET), 2021, : 172 - 175