Analysis of the heat collection performance of a capillary solar heat collection wall structure

被引:0
|
作者
Lu, Zhiheng [1 ]
Zhang, Guangli [1 ]
Niu, Xiaofeng [1 ]
Zhou, Junming [1 ]
Xie, Xin [1 ]
Hu, Yuxing [1 ]
机构
[1] Nanjing Tech Univ, Coll Urban Construct, Nanjing 211816, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Capillary solar heat collection wall structure; Building facade-integrated solar heat collector; Solar hot water supply; Heat collection efficiency; Outdoor field testing; THERMAL COLLECTORS; BIPV/T FACADES; TRANSPARENT; OPPORTUNITY;
D O I
10.1016/j.applthermaleng.2023.122263
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar thermal utilization in high-rise buildings is often constrained by the limited surface area of the rooftop. A novel facade-integrated capillary solar heat collection wall structure was proposed in this study, which involves embedding capillary tubes that circulate water within the cement mortar material, facilitating the integration of solar thermal collector and the exterior walls. To validate the feasibility of this new type of heat collection structure, experiments were conducted to investigate the impact of water flow rates on the heat collection performance of the proposed capillary solar heat collection wall structure under indoor solar simulator conditions, and outdoor field testing were conducted to assess its heat collection performance during winter, spring, and summer in Nanjing city. The experimental results revealed that, at water flow velocities of 0.05 m/s, 0.10 m/ s, 0.15 m/s, and 0.20 m/s, the system's heat collection reached 4721 kJ, 4833 kJ, 4872 kJ, and 5326 kJ, respectively, showing a consistent increase with higher flow velocities in the capillary tube. The heat collection efficiency also increased gradually with flow velocity, but the rate of increase was relatively slow. The instantaneous heat collection efficiency decreased gradually as the experiment progressed, with a relatively small value of 47 % at a flow rate of 0.05 m/s. Data fitting revealed a linear relationship between the instantaneous collector efficiency and the normalized temperature difference at water flow velocities of 0.05 m/s and 0.1 m/s, and a quadratic exponential relationship at water flow velocities of 0.15 m/s and 0.2 m/s. During winter, spring, and summer in Nanjing city, the effective heat collection efficiency reached 45.8 %, 40.4 %, and 39.5 %, respectively, demonstrating that the capillary solar heat collection wall structure has significant potential in subtropical regions like Nanjing.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Development and thermal performance of a wall heat collection prototype
    Lai, Chi-ming
    Chen, Rong-Horng
    Huang, C. S.
    BUILDING AND ENVIRONMENT, 2012, 57 : 156 - 164
  • [2] Study on the performance of a solar collector with heat collection and storage
    Li, Gang
    Huang, Huilan
    Zhang, Junjie
    Zhang, Hua
    APPLIED THERMAL ENGINEERING, 2019, 147 : 380 - 389
  • [3] Thermal performance of a solar heat collection and storage wall with night insulation in winter: A numerical study
    Sun, Yafen
    Zhang, Nan
    Zhang, Zhaoli
    Sultan, Muhammad
    Yuan, Yanping
    ENERGY AND BUILDINGS, 2024, 303
  • [4] Performance Improvement of Liquid-Type Solar Heat Collection System
    Choi, Youngjin
    2018 7TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2018, : 215 - 220
  • [5] Performance Analysis of Parabolic Trough Receiver with Inner Tube and Fins for Solar Cascade Heat Collection
    Liu, Peng
    Ma, Haiwen
    Wu, Yunlei
    Chen, Lingen
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (10): : 3143 - 3150
  • [6] HEAT COLLECTION EXPERIMENT OF SOLAR COLLECTOR WITH HEAT PIPE ABSORBER.
    Ezawa, Noboru
    Sawata, Shinji
    Tanaka, Tadayoshi
    Sakuta, K.
    Fujiwara, Masanori
    Tsuda, Izumi
    Tani, Tatsuo
    Bulletin of the Electrotechnical Laboratory, Tokyo, 1982, 46 (10): : 14 - 20
  • [7] Heat collection performance of different modes of fan-coil units-heat pump combined heat collection system
    Song W.
    Geng R.
    Wang J.
    Liu P.
    Chen X.
    Wang P.
    Wang, Pingzhi (wpz@cau.edu.cn), 1600, Chinese Society of Agricultural Engineering (37): : 230 - 238
  • [8] PERFORMANCE OF A SOLAR HEAT COLLECTION AND RELEASE SYSTEM FOR IMPROVING NIGHT TEMPERATURE IN A CHINESE SOLAR GREENHOUSE
    Fang, H.
    Yang, Q.
    Zhang, Y.
    Sun, W.
    Lu, W.
    Tong, Y.
    Liang, H.
    APPLIED ENGINEERING IN AGRICULTURE, 2015, 31 (02) : 283 - 289
  • [9] Theoretical analysis on characteristics of freezing and performance of heat transfer in heat pump system with freezing latent heat collection
    Qian, Jianfeng
    Sun, Dexing
    Zhang, Chenghu
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2007, 28 (11): : 1200 - 1205
  • [10] Theoretical analysis on heat transfer of heat pump system with freezing heat collection
    Qian, Jianfeng
    Xu, Ying
    Sun, Dexing
    Wu, Xuehui
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 812 - 816